IEC 60335-2-80:2024

Title
Abstract

IEC 60335-2-80:2024 deals with the safety of electric fans for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including direct current (DC) supplied appliances and battery-operated appliances.
Examples of the types of fans that this standard is applicable to are
- ceiling fans;
- duct fans;
- infant fans;
- partition fans;
- pedestal fans;
- table fans.
This standard also applies to separate controls supplied with fans.
Infant fans are also tested to the applicable requirements of the ISO 8124 series, since it covers hazards other than those arising from the use of electricity such as toxicological hazards.
Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended for use in shops, in light industry and on farms, are within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account:
- persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
- children playing with the appliance.
Attention is drawn to the fact that
- for appliances intended to be used in vehicles or on-board ships or aircraft, additional requirements can be necessary;
- in many countries additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to
- appliances intended exclusively for industrial purposes;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
- fans incorporated in other appliances.
This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with IEC 60335-1:2020;
b) conversion of some notes to normative text (Clause 1);
c) introduction of requirements for infant fans (7.12, 7.12.1, 8.1.1, 11.8, 20.2, 21.103, 22.44, 22.54, 22.102, B.22.3, B.22.4);
d) introduction of the use of test probe 19 (8.1.1, 20.2, B.22.3, B.22.4);
e) introduction of surface temperature limits (Clause 11);
f) clarification of testing of fans for use in a tropical climate (5.7, Annex P 11.8);
g) clarification of requirements for remote operation of fans (22.40, 22.49, 22.51).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

Issue Date

2024-10-30

Category

HOUS

Included in IECEE System

2024-11-11

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

JapanJapan

2025-03-18

Download58 kb

Laboratory Name

City

Country

Responsible National Certification Body

Noida – 201301

India

Arnhem

Netherlands

Shanghai 200436

China

Guangzhou

China

Dresden

Germany

Osnago (LC)

Italy

Bangkok 10320

Thailand

New Delhi

India

Kista

Sweden

Shanghai

China

Kowloon

Hong Kong

Guangzhou, Guangdong

China

Guangdong

China

Bangkok 10510

Thailand

Shenzhen City, Guangdong Province

China

Guangzhou

China

Gyeonggi-do 12735

Korea, Republic of

Istanbul

Türkiye

Guangzhou

China

Ningbo

China

Fareham, Hampshire PO15 5RL

United Kingdom

Volpiano (TO)

Italy

Guangzhou

China

Budapest

Hungary

Seoul, 07298

Korea, Republic of

Pathumthani

Thailand

San Diego

United States of America

Shenzhen, Guangdong

China

Seoul 07326

Korea, Republic of

Frankfurt

Germany

München

Germany

Auckland

New Zealand

Northbrook, IL 60062

United States of America

Uttar Pradesh

India

Offenbach / Main

Germany

Ningbo, Zhejiang

China

Id

Name

City

Country

13360

Arnhem

Netherlands

13348

Reichenwalde b. Berlin

Germany

13371

Kista

Sweden

13365

Singapore

Singapore

13358

Gunpo-si, Gyeonggi-do, 15809

Korea, Republic of

13749

NL - 7327 AC Apeldoorn

Netherlands

13356

Gyeongsangnam-do

Korea, Republic of

13343

Fontenay-Aux-Roses

France

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

13349

Budapest

Hungary

13354

Yokohama

Japan

13427

Singapore 609937

Singapore

13346

München

Germany

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany

Id

Name

City

Country

25774

Sunnyvale,

United States of America

13641

Paris Cedex 15

France

28413

Singapore

Singapore