IEC 60335-2-69:2016

Title
Abstract

IEC 60335-2-69:2016 is available as IEC 60335-2-69:2016RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60335-2-69:2016 deals with the safety of electrical motor-operated vacuum cleaners, including back-pack vacuum cleaners, and dust extractors, for wet suction, dry suction, or wet and dry suction, intended for commercial indoor or outdoor use with or without attachments. They may be provided with a blowing or inflating function. It also deals with the safety of centrally-sited vacuum cleaners, excluding the installation of the system. Requirements on the safe installation of centrally-sited vacuum cleaners are not addressed by this standard but need to be taken into account. This standard applies to machines for commercial use. The following list, although not comprehensive, gives an indication of locations that are included in the scope:
- public use areas such as hotels, schools, hospitals;
- industrial locations, for example factories and manufacturing shops;
- retail outlets, for example shops and supermarkets;
- business premises, for example offices and banks and
- all uses other than normal housekeeping purposes. They are not equipped with a traction drive. The following power systems are covered: mains powered motors up to a rated voltage of 250 V for single-phase appliances and 480 V for other appliances, and battery powered motors. This standard also applies to machines handling hazardous dust, such as asbestos. This standard does not apply to:
- vacuum cleaners and water-suction cleaning appliances for household use;
- floor treatment machines for commercial use;
- spray extraction machines for commercial use;
- hand-held mains-operated electrical garden blowers, vacuums and blower vacuums;
- hand-held and transportable motor-operated electric tools;
- appliances for medical purposes;
- machines designed for use in corrosive environments;
- machines designed for picking up liquids with a flash point below 55 °C and machines designed for use in explosive environments (dust, vapour or gas), except those designed for use in zone 22. This fifth edition cancels and replaces the fourth edition published in 2012. It constitutes a technical revision. The principal changes in this edition as compared with the third edition of IEC 60335-2-69 are as follows (minor changes are not listed):
- the scope has been revised editorially to avoid misunderstandings;
- terms and definitions has been revised with regard to the requirements revised;
- the standard has been revised in general and updated regarding state-of-the-art, as far as necessary, in particular some changes have been made to Clauses 15, 22 and 25;
- the standard has been aligned with the newest amendment of IEC 60335-1:2010+A1:2013;
- Annex AA was revised and restructured;
- Annex CC was revised;
- general additions for vacuum cleaners with blowing functions have been introduced and a new Annex GG 'Particular requirements for mobile wet vacuum cleaners for rescue and firefighting services (MWF)' was added. It was established on the basis of the fifth edition (2010) of that standard. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication. Key words: Vacuum Cleaner, Commercial Use, Wet and Dry Vacuum Cleaner, Power Brush

This publication is to be read in conjunction with IEC 60335-1:2010.

Issue Date

2016-06-14

Category

HOUS

Included in IECEE System

2016-10-26

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

AustraliaAustralia

2023-05-30

Download178 kb

AustraliaAustralia

2021-10-06

Download70 kb

CanadaCanada

2023-11-03

Download2 Mb

New ZealandNew Zealand

2022-07-26

Download112 kb

New ZealandNew Zealand

2023-05-30

Download178 kb

Laboratory Name

City

Country

Responsible National Certification Body

94342 Strasskirchen

Germany

Toronto

Canada

Arnhem

Netherlands

Shanghai 200436

China

Guangzhou

China

Dresden

Germany

Osnago (LC)

Italy

Hull

United Kingdom

Shanghai

China

Milano

Italy

Kaufbeuren

Germany

Campoformido (UD)

Italy

Fridley,

United States of America

Plano,

United States of America

Kista

Sweden

Milton Keynes

United Kingdom

Kowloon

Hong Kong

Shanghai

China

Guangzhou, Guangdong

China

Shenzhen City, Guangdong Province

China

Biassono (MB)

Italy

Lysaker

Norway

Shenzhen, Guangdong

China

Toronto

Canada

Shanghai

China

Ningbo

China

Shunde District,

China

Ljubljana

Slovenia

Hartmannsdorf

Germany

Guangdong Province

China

Wien

Austria

Volpiano (TO)

Italy

Guangzhou

China

Shanghai

China

Shenzhen 518052

China

Pogliano Milanese

Italy

Köln

Germany

San Diego

United States of America

Guangzhou

China

Shanghai

China

Frankfurt

Germany

20061 Carugate (MI)

Italy

North Carolina

United States of America

Suzhou

China

Offenbach / Main

Germany

Warsaw

Poland

Id

Name

City

Country

13336

Toronto, Ontario

Canada

13360

Arnhem

Netherlands

13478

Skelmersdale

United Kingdom

13348

Reichenwalde b. Berlin

Germany

13351

Milano

Italy

13371

Kista

Sweden

13375

Surrey

United Kingdom

13365

Singapore

Singapore

13356

Seoul

Korea, Republic of

13361

Lysaker

Norway

13332

Vienna

Austria

13469

Toronto,

Canada

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

13367

Ljubljana

Slovenia

13347

Hartmannsdorf

Germany

13354

Yokohama

Japan

13345

Nürnberg

Germany

13427

Singapore 609937

Singapore

13346

München

Germany

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany

13364

Warsaw

Poland