IEC 60335-2-40:2022

Title
Abstract

IEC 60335-2-40:2022 deals with the safety of electric heat pumps, sanitary hot water heat pumps and air conditioners, incorporating motor-compressors as well as hydronic fan coils units, dehumidifiers (with or without motor-compressors), thermoelectric heat pumps and partial units. Their maximum rated voltage being not more than 300 V for single phase appliances and 600 V for multi-phase appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. The appliances referenced above can consist of one or more factory-made assemblies. If provided in more than one assembly, the separate assemblies are used together, and the requirements are based on the use of matched assemblies. This document does not take into account refrigerants other than group A1, A2L, A2 and A3 as defined by ISO 817. Flammable refrigerants are limited to those of a molar mass of more than or equal to 42 kg/kmol based on WCF (worst case formulation) as specified in ISO 817. As far as practical, this document deals with common hazards presented by appliances that are encountered in normal use and assumes that installation, servicing, decommissioning, and disposal are safely handled by competent persons and accidental release of refrigerants is avoided. However, it does not prescribe the criteria to ensure competence of persons during installation, servicing and disposal. Safety requirements during disposal are not specified in this standard. Supplementary heaters, or a provision for their separate installation, are within the scope of this standard, but only heaters which are designed as a part of the appliance package, the controls being incorporated in the appliance. Attention is drawn to the fact that
- for appliances intended to be used in vehicles or on-board ships or aircraft, additional requirements can be necessary;
- in many countries, additional requirements are specified, for example, by the national health authorities responsible for the protection of labour and the national authorities responsible for storage, transportation, building constructions and installations.
This document does not apply to
- humidifiers intended for use with heating and cooling equipment (IEC 60335-2-88);
- appliances designed exclusively for industrial processing;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
This seventh edition cancels and replaces the sixth edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- Clause 1: added thermoelectric heat pumps to the scope and increased maximum rated voltage to 300 V for single phase appliances;
- Clause 7: revised requirements for marking on the appliance and packaging, including a symbol for minimum floor area and modifying the symbol for flammable refrigerants to include the safety group per ISO 817;
- Clause 11 and Clause 19: restructured for alignment with Part 1 and added requirements for supplementary air heaters;
- Clause 13 and Clause 16: revised requirement for leakage current for stationary class I motor-operated appliances;
- Clause 21: added requirements for particle foam material and revised requirements for transport testing;
- Clause 22: removed limit on the sum of refrigerant charges for appliances with multiple refrigerating systems, and revised requirements for avoiding ignition sources, leak detection systems, safety shut-off valves, and particle foam material;
- Clause 23: added requirements to avoid contact between wires and refrigerant piping;
- Clause 24

Issue Date

2022-05-25

Category

HOUS

Included in IECEE System

2022-06-24

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

CanadaCanada

2024-01-08

Download4 Mb

New ZealandNew Zealand

2024-04-15

Download113 kb

Laboratory Name

City

Country

Responsible National Certification Body

Guangzhou

China

Guangzhou

China

Jiaxing

China

Guangzhou,

China

Arnhem

Netherlands

Guangzhou

China

Gyeonggi-do

Korea, Republic of

182 00 Praha 8 – Troja

Czech Republic

Kaufbeuren

Germany

New Delhi

India

Campoformido (UD)

Italy

Istanbul

Türkiye

Bangkok 10800

Thailand

Kowloon

Hong Kong

Shanghai

China

Guangzhou, Guangdong

China

Bangkok

Thailand

Seoul 08389

Korea, Republic of

Fontenay-Aux-Roses

France

Shanghai

China

Gyeonggi-do

Korea, Republic of

Chonburi

Thailand

Madrid

Spain

Shanghai

China

Hefei, Anhui

China

Guangzhou

China

Shunde District,

China

Guangzhou

China

Shanghai

China

Shenzhen 518052

China

Osaka 537-0002,

Japan

Yokohama,

Japan

Seoul, 07298

Korea, Republic of

Köln

Germany

Shah Alam

Malaysia

Bangkok 10520

Thailand

Ningbo

China

Guangzhou

China

Seoul

Korea, Republic of

Frankfurt

Germany

Amphur Muang Samutprakarn

Thailand

20061 Carugate (MI)

Italy

Offenbach / Main

Germany

Id

Name

City

Country

13336

Toronto, Ontario

Canada

27124

Guangzhou

China

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13339

Praha 8 - Troja 171 02

Czech Republic

13371

Kista

Sweden

13365

Singapore

Singapore

13359

Gyeonggi-do

Korea, Republic of

13356

Seoul

Korea, Republic of

13343

Fontenay-Aux-Roses

France

13361

Lysaker

Norway

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

28413

Singapore

Singapore

13354

Yokohama

Japan

13345

Nürnberg

Germany

13427

Singapore 609937

Singapore

13346

München

Germany

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany

Id

Name

City

Country

13422

Milton Keynes

United Kingdom

20269

Modiin

Israel

13749

NL - 7327 AC Apeldoorn

Netherlands

13469

Toronto,

Canada

25918

Tai Po,

China

13349

Budapest

Hungary