IEC 60335-2-37:2017

Title
Abstract

IEC 60335-2-37:2017 deals with the safety of electrically operated commercial deep fat fryers and doughnut fryers including pressurized types with a pressure not exceeding 50 kPa and a pressure volume litres product of 200. These appliances are not intended for household and similar use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances.
These appliances are used for the commercial processing of food, for example in kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries, butcheries, etc.
The electrical part of appliances making use of other forms of energy is also within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by these types of appliances.
This standard does not apply to:
- appliances designed exclusively for industrial purposes;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); or
- appliances for continuous mass production of food.
This sixth edition cancels and replaces the fifth edition published in 2002 including its Amendment 1 (2008) and its Amendment 2 (2011). This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- stating some wording in the scope more precisely;
- addition of a measurement method for pans in the definition for normal operation;
- new definitions on the topic surface temperature;
- deletion of the paragraph with the warning for dangerous voltages (already covered by Part 1);
- addition of hot surface symbol IEC 60417-5041;
- addition of instructions and markings on hot surfaces and other topics;
- addition of requirements, measuring methods and thresholds for different materials on hot surfaces;
- modification on leakage current defining the value for appliances with a power consumption less than 1 kW;
- modification on the criteria for the stability test;
- addition of a requirement for the construction of stationary appliances with rollers or castors;
- modification on some points concerning permanent connection to fixed wiring;
- addition of specific requirements concerning types of screws to be used for electrical connections and connections for earth continuity;
- addition of a figure showing the surfaces to be measured;
- addition of a figure showing the probe for measuring surface temperatures and the addition of informative Annex P dealing with leakage currents for appliances used in tropical climates.
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of the fifth edition (2010) of that standard.
The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests.
It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication.
This publication is to be read in conjunction with IEC 60335-1:2010.

Issue Date

2017-04-10

Category

HOUS

Included in IECEE System

2017-06-02

Purchase webstore
Test Report Form
Testing Equipment List

No information declared

DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

CanadaCanada

2022-01-04

Download73 kb

CENELECCENELEC

2019-10-25

Download306 kb

Laboratory Name

City

Country

Responsible National Certification Body

Istanbul

Türkiye

Beijing

China

Guangzhou,

China

Arnhem

Netherlands

Shanghai 200436

China

Guangzhou

China

Fehraltorf

Switzerland

Guangzhou

China

Milano

Italy

San Vendemiano (Treviso)

Italy

Kaufbeuren

Germany

Duluth,

United States of America

Campoformido (UD)

Italy

Plano,

United States of America

Milton Keynes

United Kingdom

Shanghai

China

Kowloon

Hong Kong

Guangzhou, Guangdong

China

Haining City

China

Kanagawa-ken

Japan

Padova

Italy

NL - 7327 AC Apeldoorn

Netherlands

Fontenay-Aux-Roses

France

Getafe - Madrid

Spain

Hamburg

Germany

Madrid

Spain

Istanbul

Türkiye

Shanghai

China

Guangzhou

China

Genas

France

Buenos Aires

Argentina

Volpiano (TO)

Italy

Essen

Germany

Budapest

Hungary

Pogliano Milanese

Italy

Köln

Germany

Alpharetta

United States of America

Guangzhou

China

Shenzhen, Guangdong

China

München

Germany

20061 Carugate (MI)

Italy

Northbrook, IL 60062

United States of America

Warsaw

Poland

Id

Name

City

Country

13370

Madrid

Spain

13864

COURBEVOIE

France

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13351

Milano

Italy

13330

Buenos Aires

Argentina

13371

Kista

Sweden

13375

Surrey

United Kingdom

13365

Singapore

Singapore

13352

Tokyo

Japan

13749

NL - 7327 AC Apeldoorn

Netherlands

13343

Fontenay-Aux-Roses

France

13361

Lysaker

Norway

13843

Hamburg

Germany

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

13617

Essen

Germany

13349

Budapest

Hungary

13345

Nürnberg

Germany

13427

Singapore 609937

Singapore

13346

München

Germany

13340

Ballerup

Denmark

13364

Warsaw

Poland

Id

Name

City

Country

13721

Minsk

Belarus

13372

Fehraltorf

Switzerland

13469

Toronto,

Canada

27899

Queensland

Australia

13373

Bakanliklar, Ankara

Türkiye