IEC 60335-2-36:2017

Title
Abstract

IEC 60335-2-36:2017 deals with the safety of electrically operated commercial cooking and baking ranges, ovens, hobs, hob elements and similar appliances not intended for household and similar use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances.
These appliances are used for the commercial processing of food, for example in kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries, butcheries, etc.
The electrical part of appliances making use of other forms of energy is also within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by these types of appliances.
This standard does not apply to:
- appliances designed exclusively for industrial purposes;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
- appliances for continuous mass production of food;
- steam cookers, forced and steam convection ovens (IEC 60335-2-42);
- hot cupboards (IEC 60335-2-49) or microwave ovens (IEC 60335-2-90).
This sixth edition cancels and replaces the fifth edition published in 2002 including its Amendment 1 (2004) and its Amendment 2 (2008). This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- stating some wording in the scope more precisely;
- addition of a measurement method for pans in the definition for normal operation;
- new definitions on the topic surface temperature;
- deletion of the paragraph with the warning for dangerous voltages (already covered by Part 1);
- addition of hot surface symbol IEC 60417-5041;
- addition of instructions and markings on hot surfaces and other topics;
- addition of requirements, measuring methods and thresholds for different materials on hot surfaces;
- modification on leakage current defining the value for appliances with a power consumption less than 1 kW;
- modification on the measurement method for induction heating sources in abnormal operation;
- addition of a requirement for the construction of stationary appliances with rollers or castors;
- modification on some points concerning permanent connection to fixed wiring;
- addition of specific requirements concerning types of screws to be used for electrical connections and connections for earth continuity;
- addition of a figure showing the surfaces to be measured;
- addition of a figure showing the probe for measuring surface temperatures;
- addition of a figure showing the disc for the pan detection on induction heating sources and addition of informative Annex P dealing with leakage currents for appliances used in tropical climates.
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of the fifth edition (2010) of that standard
The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests.
It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication.
This publication is to be read in conjunction with IEC 60335-1:2010.

Issue Date

2017-04-10

Category

HOUS

Included in IECEE System

2017-06-02

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

CanadaCanada

2023-02-01

Download80 kb

CENELECCENELEC

2019-10-22

Download315 kb

CENELECCENELEC

2018-01-25

Download277 kb

Laboratory Name

City

Country

Responsible National Certification Body

Istanbul

Türkiye

94342 Strasskirchen

Germany

Guangzhou,

China

Arnhem

Netherlands

Shanghai 200436

China

Guangzhou

China

Osnago (LC)

Italy

Shanghai

China

Guangdong

China

Guangzhou

China

Belforte del Chienti (MC)

Italy

Milano

Italy

San Vendemiano (Treviso)

Italy

Arlington Heights

United States of America

Kaufbeuren

Germany

Campoformido (UD)

Italy

Plano,

United States of America

Kista

Sweden

Milton Keynes

United Kingdom

Kowloon

Hong Kong

Shanghai

China

Guangzhou, Guangdong

China

Kanagawa-ken

Japan

Osaka

Japan

Padova

Italy

Guangzhou

China

NL - 7327 AC Apeldoorn

Netherlands

Kaufbeuren

Germany

Fontenay-Aux-Roses

France

Barcelona

Spain

Getafe - Madrid

Spain

Gyeonggi-do 12735

Korea, Republic of

Istanbul

Türkiye

Shanghai

China

Guangzhou

China

Ljubljana

Slovenia

Tel-Aviv

Israel

Essen

Germany

Guangzhou

China

Shanghai

China

Shenzhen 518052

China

Limonest

France

Budapest

Hungary

Pogliano Milanese

Italy

Köln

Germany

Guangzhou 510656

China

Shanghai

China

Shenzhen, Guangdong

China

Garching

Germany

Neu-Isenburg (Zeppelinheim)

Germany

20061 Carugate (MI)

Italy

Offenbach / Main

Germany

Shunde District, Foshan

China

Warsaw

Poland

Id

Name

City

Country

13370

Madrid

Spain

13336

Toronto, Ontario

Canada

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13348

Reichenwalde b. Berlin

Germany

13351

Milano

Italy

13371

Kista

Sweden

13375

Surrey

United Kingdom

13365

Singapore

Singapore

13352

Tokyo

Japan

13353

Tokyo

Japan

13358

Gunpo-si,Gyeonggi-do, 15809

Korea, Republic of

13749

NL - 7327 AC Apeldoorn

Netherlands

13343

Fontenay-Aux-Roses

France

13361

Lysaker

Norway

13469

Toronto,

Canada

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

13597

Tel-Aviv

Israel

13367

Ljubljana

Slovenia

13617

Essen

Germany

13349

Budapest

Hungary

13354

Yokohama

Japan

13345

Nürnberg

Germany

13427

Singapore 609937

Singapore

13346

München

Germany

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany

13364

Warsaw

Poland

Id

Name

City

Country

13721

Minsk

Belarus

27899

Queensland

Australia

13373

Bakanliklar, Ankara

Türkiye