IEC 61000-4-6:2023

Title
Abstract

IEC 61000-4-6:2023 is available as IEC 61000-4-6:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61000-4-6: 2023 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz.
NOTE 1 Product committees might decide to use the methods described in this document also for frequencies up to 230 MHz (see Annex B) although the methods and test instrumentation are intended to be used in the frequency range up to 80 MHz.
Equipment not having at least one conducting wire or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this document.
NOTE 2 Test methods are specified in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods specified are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects.
The object of this document is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method in this document describes a consistent method to assess the immunity of an equipment or system against a specified phenomenon.
NOTE 3 As described in IEC Guide 107, this document is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria.
This fifth edition cancels and replaces the fourth edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) selection of injection devices revised;
b) need of AE impedance check for clamp injection removed and Annex H deleted;
c) saturation check revised;
d) new Annex H on testing with multiple signals;
e) level-setting only with feedback loop.

Issue Date

2023-06-06

Category

EMC

Included in IECEE System

2023-09-25

Purchase webstore
Test Report Form

No information declared

Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

No information declared

Laboratory Name

City

Country

Responsible National Certification Body

Scandicci (FI)

Italy

Guangzhou

China

Arnhem

Netherlands

Shanghai 200436

China

Guangzhou

China

Suzhou

China

Hsinchu County 31061

Chinese Taipei

New Taipei City

Chinese Taipei

Campanillas

Spain

9400 Rorschach

Switzerland

Shanghai

China

Guangzhou, Guangdong

China

Seoul 08389

Korea, Republic of

Shanghai

China

Nanjing

China

Budapest

Hungary

20061 Carugate (MI)

Italy

Shaanxi

China

Id

Name

City

Country

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13372

Fehraltorf

Switzerland

13371

Kista

Sweden

13365

Singapore

Singapore

13356

Seoul

Korea, Republic of

13334

BRUSSELS 1070

Belgium

13349

Budapest

Hungary

13340

Ballerup

Denmark

Id

Name

City

Country

28413

Singapore

Singapore