IEC 60335-2-69:2021

Title
Abstract

IEC 60335-2-69:2021 deals with the safety of electrical motor-operated vacuum cleaners, including back-pack vacuum cleaners, and dust extractors, for wet suction, dry suction, or wet and dry suction, intended for commercial indoor or outdoor use with or without attachments. These machines may be provided with a blowing or inflating function. The inner diameter of the dust container connector to the suction hose shall not exceed 200 mm.
It also deals with the safety of centrally-sited vacuum cleaners, excluding the installation of the system.
Attention is drawn to the fact that additional requirements on the safe installation of centrally-sited vacuum cleaners are not addressed by this standard but need to be taken into account.
This standard applies to machines for commercial use. The following list, although not comprehensive, gives an indication of locations that are included in the scope:
– public use areas such as hotels, schools, hospitals;
– industrial locations, for example factories and manufacturing shops;
– retail outlets, for example shops and supermarkets;
– business premises, for example offices and banks;
– all uses other than normal housekeeping purposes.
These machines are not equipped with a traction drive. The following power systems are covered:
– mains powered motors up to a rated voltage of 250 V for single-phase appliances and 480 V for other appliances,
– battery-operated motors.
Machines for the same intended function but equipped with a traction drive are covered by IEC 60335-2-72.
This standard also applies to machines handling hazardous dust, such as asbestos, and combustible dust in other than an explosive dust atmosphere.
Additional requirements for machines handling hazardous dust are given in normative Annex AA. Attention is drawn to the fact that in many countries additional requirements on hazardous substances might apply.
Radioactive substances are not covered by definition of hazardous dust for the purposes of this standard.
This standard does not apply to
– vacuum cleaners and water-suction cleaning appliances for household use (IEC 60335-2-2);
– floor treatment machines for commercial use (IEC 60335-2-67, IEC 60335-2-72);
– spray extraction machines for commercial use (IEC 60335-2-68);
IEC 60335-2-67 and IEC 60335-2-68 cover only machines without traction drive.
– hand-held mains-operated electrical garden blowers, vacuums and blower vacuums (IEC 60335-2-100);
– hand-held and transportable motor-operated electric tools (IEC 60745 series, IEC 61029 series, IEC 62841 series);
– appliances for medical purposes (IEC 60601-1);
– machines designed for use in corrosive environments;
– machines designed for picking up liquids with a flash point below 55 °C;
– machines designed for use in explosive environments (dust, vapour or gas), except those designed for use in zone 22;
– machines intended to vacuum ash from fireplaces, chimneys, ovens, ashtrays and similar places of ash accumulation.
This sixth edition cancels and replaces the fifth edition published in 2016. It constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– editorial and technical alignment with IEC 60335-1:2020;
– addition of requirements for pick-up of combustible dusts in other than an explosive dust atmosphere.
This part 2 is only to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of the sixth edition (2020) of that standard.

Issue Date

2021-04-21

Category

HOUS

Included in IECEE System

2021-05-12

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

CanadaCanada

2023-10-20

Download2 Mb

Laboratory Name

City

Country

Responsible National Certification Body

94342 Strasskirchen

Germany

Arnhem

Netherlands

Shanghai 200436

China

Guangzhou

China

Dresden

Germany

Osnago (LC)

Italy

Shanghai

China

Milano

Italy

Kaufbeuren

Germany

Campoformido (UD)

Italy

Plano,

United States of America

Kista

Sweden

Kowloon

Hong Kong

Shanghai

China

Guangzhou, Guangdong

China

Shenzhen City, Guangdong Province

China

Shanghai

China

Biassono (MB)

Italy

Lysaker

Norway

Shenzhen, Guangdong

China

Shanghai

China

Ningbo

China

Hartmannsdorf

Germany

Guangdong Province

China

Volpiano (TO)

Italy

Guangzhou

China

Shanghai

China

Shenzhen 518052

China

Pogliano Milanese

Italy

Seoul, 07298

Korea, Republic of

San Diego

United States of America

Jiangsu

China

Guangzhou

China

Shanghai

China

Frankfurt

Germany

20061 Carugate (MI)

Italy

North Carolina

United States of America

Offenbach / Main

Germany

Id

Name

City

Country

13336

Toronto, Ontario

Canada

13360

Arnhem

Netherlands

13348

Reichenwalde b. Berlin

Germany

13351

Milano

Italy

13371

Kista

Sweden

13365

Singapore

Singapore

13356

Seoul

Korea, Republic of

13343

Fontenay-Aux-Roses

France

13361

Lysaker

Norway

13334

BRUSSELS 1070

Belgium

13347

Hartmannsdorf

Germany

13354

Yokohama

Japan

13345

Nürnberg

Germany

13427

Singapore 609937

Singapore

13346

München

Germany

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany