IEC 60335-2-24:2020

Title
Abstract

IEC 60335-2-24:2020 deals with the safety of the following appliances, their rated voltage being not more than 250 V for single-phase appliances, 480 V for other appliances and 24 V DC for appliances when battery operated:
– refrigerating appliances for household and similar use;
– ice-makers incorporating a motor-compressor and ice-makers intended to be incorporated in frozen food storage compartments;
– refrigerating appliances and ice-makers for use in camping, touring caravans and boats for leisure purposes.
These appliances may be operated from the mains, from a separate battery or operated either from the mains or from a separate battery.
This standard also deals with the safety of ice-cream appliances intended for household use, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances.
It also deals with compression-type appliances for household and similar use, which use flammable refrigerants.
This standard does not cover features of the construction and operation of those refrigerating appliances which are dealt with in other IEC standards.
Refrigerating appliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as
– refrigerating appliances used in staff kitchen areas in shops, offices and other working environments,
– refrigerating appliances used in farm houses and by clients in hotels, motels and other residential type environments,
– refrigerating appliances used in bed and breakfast type environments, and
– refrigerating appliances used in catering and similar non-retail applications
are within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account
– persons (including children) whose physical, sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
– children playing with the appliance.
Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements are specified by national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
This standard does not apply to
– appliances intended to be used in the open air;
– appliances designed exclusively for industrial purposes;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– appliances incorporating a battery intended as a power supply for the refrigerating function;
– appliances assembled on site by the installer;
– appliances with remote motor-compressors;
– motor-compressors (IEC 60335-2-34);
– commercial dispensing appliances and vending appliances (IEC 60335-2-75);
– commercial refrigerating appliances and ice-makers with an incorporated or remote refrigerant unit or motor-compressor (IEC 60335-2-89);
– professional ice-cream makers (IEC 60335-2-118).

This eighth edition cancels and replaces the seventh edition published in 2010, Amendment 1:2012 and Amendment 2:2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– aligns the text with IEC 60335-1, Ed 5.2;
– some notes have been converted to normative text or deleted (4, 5.2, 5.7, 7.1, 7.6, 7.10, 7.12, 19.1, 19.101, 19.102, 20.101, 20.102, 20.103, 20.104, 21, 22.7, 22.33, 22.101, 22.102, 22.103, 22.107, 22.108, 22.109, 30.1);
– normative references and associated text have been updated (2, 22.108, 22.109, Table 102, Annex CC);
– definition of free space has been clarified (3.6.104);
– measurement of the input current of refrigerating appliances using inverter driven motor-compressors is included (10.2);
– compatibility tests for winding insulation of motor-compressors used with different types of refrigerants and oils have been introduced (22.9);
– requirements for inadvertent contact points between uncoated aluminium pipes and copper pipes have been updated (22.111);
– testing of accessible glass panels has been clarified (22.116);
– in refrigerating appliances, requirements for material encasing and in contact with thermal insulation have been introduced and consequential text has been deleted (22.117, 30.2, 30.2.101, Annex EE);
– requirements for motor running capacitors have been updated (24.5, 24.8);
– the locked rotor test for fan motors has been clarified (Annex AA).

This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of the fifth edition (2010) of that standard.
The contents of the corrigendum of August 2021 have been included in this copy.

Issue Date

2020-09-16

Category

HOUS

Included in IECEE System

2020-09-24

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

AustraliaAustralia

2021-12-19

Download115 kb

CanadaCanada

2023-03-03

Download541 kb

CENELECCENELEC

2024-02-22

Download322 kb

New ZealandNew Zealand

2024-04-07

Download322 kb

New ZealandNew Zealand

2022-06-09

Download188 kb

Laboratory Name

City

Country

Responsible National Certification Body

Chuzhou

China

Castle Hill

Australia

Minsk

Belarus

Guangzhou

China

Guangzhou

China

Beijing

China

Suzhou

China

Jiaxing

China

Guangzhou,

China

Guangzhou

China

Guangdong

China

Arnhem

Netherlands

Hefei

China

Guangzhou

China

Campanillas

Spain

Osnago (LC)

Italy

Ha Noi

Viet Nam

Gyeonggi-do

Korea, Republic of

P.O. Box 67, Dubai

United Arab Emirates

London

United Kingdom

Fehraltorf

Switzerland

Shanghai

China

Gyeonggi-do

Korea, Republic of

Bangkok 10320

Thailand

Guangdong

China

Hefei

China

46210 Picanya

Spain

Belforte del Chienti (MC)

Italy

Milano

Italy

Arlington Heights

United States of America

Kaufbeuren

Germany

Gunpo-si

Korea, Republic of

New Delhi

India

Campoformido (UD)

Italy

Plano,

United States of America

Kista

Sweden

Istanbul

Türkiye

Bangkok 10800

Thailand

Kowloon

Hong Kong

Shanghai

China

Guangzhou, Guangdong

China

Haining City

China

Bangkok

Thailand

Osaka

Japan

Shenzhen City, Guangdong Province

China

NL - 7327 AC Apeldoorn

Netherlands

Seoul 08389

Korea, Republic of

Shanghai

China

Getafe - Madrid

Spain

Gyeonggi-do

Korea, Republic of

Cixi City

China

Gyeonggi-do 12735

Korea, Republic of

Chonburi

Thailand

Madrid

Spain

Istanbul

Türkiye

Shanghai

China

Hefei, Anhui

China

Guangzhou

China

Ningbo

China

Shunde District,

China

Ljubljana

Slovenia

Hartmannsdorf

Germany

Genas

France

Xiaoshan

China

GEBZE 41400

Türkiye

Haryana, 122015

India

Taoyuan City

Chinese Taipei

Volpiano (TO)

Italy

Guangzhou

China

Shanghai

China

Shenzhen 518052

China

Qingdao, Shandong

China

Budapest

Hungary

Pogliano Milanese

Italy

Yokohama,

Japan

Seoul, 07298

Korea, Republic of

Köln

Germany

Taoyuan City 333

Chinese Taipei

Bangkok 10520

Thailand

Istanbul

Türkiye

Ningbo

China

Pathumthani

Thailand

Peabody

United States of America

San Diego

United States of America

Jiangsu

China

Guangzhou

China

Shanghai

China

Seoul

Korea, Republic of

Singapore 609937

Singapore

Frankfurt

Germany

Garching

Germany

Amphur Muang Samutprakarn

Thailand

Neu-Isenburg (Zeppelinheim)

Germany

20061 Carugate (MI)

Italy

Melville

United States of America

Northbrook, IL 60062

United States of America

Suzhou

China

Huangpu District, Guangzhou

China

Guangdong

China

Offenbach / Main

Germany

Warsaw

Poland

Id

Name

City

Country

13370

Madrid

Spain

13864

COURBEVOIE

France

13721

Minsk

Belarus

13336

Toronto, Ontario

Canada

27124

Guangzhou

China

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13372

Fehraltorf

Switzerland

13348

Reichenwalde b. Berlin

Germany

13351

Milano

Italy

13371

Kista

Sweden

13365

Singapore

Singapore

13353

Tokyo

Japan

13358

Gunpo-si,Gyeonggi-do, 15809

Korea, Republic of

13749

NL - 7327 AC Apeldoorn

Netherlands

13359

Gyeonggi-do

Korea, Republic of

13356

Seoul

Korea, Republic of

13343

Fontenay-Aux-Roses

France

13761

P.O. Box 6122, Dubai

United Arab Emirates

13361

Lysaker

Norway

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

28413

Singapore

Singapore

13367

Ljubljana

Slovenia

13347

Hartmannsdorf

Germany

13373

Bakanliklar, Ankara

Türkiye

13349

Budapest

Hungary

13354

Yokohama

Japan

13345

Nürnberg

Germany

13427

Singapore 609937

Singapore

13346

München

Germany

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany

13364

Warsaw

Poland

Id

Name

City

Country

20269

Modiin

Israel

13599

Shah Alam, Selangor

Malaysia

25918

Tai Po,

China