UL International Demko A/S

Address(es)
  • Borupvang 5A
    DK-DK-2750 Ballerup
    Denmark
    +45 44 85 65 65
    +45 44 85 65 55
Website Go to website
Acceptance date 2015-10-15
Accredited by

DANAK

Certificate

Download

Contacts

Contacts


Subcontracts for CB Testing Laboratory(ies)

No information declared

Category

Name

Tests/Clauses

Test from IECEE 02-2 Annex A

Specific Test

Used in product categories

Acceptance Date

Responsible National Certification Body

ITAV

500W flame test apparatus in acc. to IEC 60695-11-20:1999: Annex S
  • Resistance to heat and fire testing
  • Thermoplastics testing (i.e. short-term property evaluations, long-term property evaluations, polymeric materials used in electrical equipment evaluations, industrial laminates, vulcanized fiber, materials used for printed wiring boards, filament wound tubing, flexible dielectric film materials, flammability, tracking, hot-wire ignition)

500W flame test apparatus in acc. to IEC 60695-11-20:1999

  • ITAV
2024-12-23

ITAV

Material group and CTI “according to IEC 60112”: 5.4.3.3;Tests for resistance to heat and fire “test according to IEC 60695-11-5”: Annex S (normative);Separation of combustible materials from a PIS “test according to IEC 60695-11-5”: 6.4.7;Constructional requirements for a fire “enclosure and a fire barrier test according to IEC 60695-11-5”: 6.4.8;Safeguards against electric shock “test according to IEC 60695-11-5”: G.8.2;500W flame test apparatus in acc. to IEC 60695-11-20:1999: 3.3.4.2-3.3.4.2.13, Annex S
  • Resistance to heat and fire testing
  • Thermoplastics testing (i.e. short-term property evaluations, long-term property evaluations, polymeric materials used in electrical equipment evaluations, industrial laminates, vulcanized fiber, materials used for printed wiring boards, filament wound tubing, flexible dielectric film materials, flammability, tracking, hot-wire ignition)

Material group and CTI “according to IEC 60112”; Tests for resistance to heat and fire “test according to IEC 60695-11-5”; Separation of combustible materials from a PIS “test according to IEC 60695-11-5”; Constructional requirements for a fire “enclosure and a fire barrier test according to IEC 60695-11-5”; Safeguards against electric shock “test according to IEC 60695-11-5”; 500W flame test apparatus in acc. to IEC 60695-11-20:1999

  • ITAV

OFF

Material group and comparative tracking index (Comparative Tracking Index): 2.10.4.2Materials (tests specified in Annex A1 and A2): 4.7.3Materials used in high-voltage Components (tests specified in Annex A or in clause14.4 of IEC 60065 or needle flame test according to IEC 60695- 11-5): 4.7.3.6
  • Thermoplastics testing (i.e. short-term property evaluations, long-term property evaluations, polymeric materials used in electrical equipment evaluations, industrial laminates, vulcanized fiber, materials used for printed wiring boards, filament wound tubing, flexible dielectric film materials, flammability, tracking, hot-wire ignition)

Material group and comparative tracking index (Comparative Tracking Index) Materials (tests specified in Annex A1 and A2) Materials used in high-voltage Components (tests specified in Annex A or in clause14.4 of IEC 60065 or needle flame test according to IEC 60695- 11-5)

  • OFF

OFF

Material group and comparative tracking index (Comparative Tracking Index): 2.10.4.2Materials (tests specified in Annex A1 and A2): 4.7.3Materials used in high-voltage Components (tests specified in Annex A or in clause14.4 of IEC: 4.7.3.6
  • Thermoplastics testing (i.e. short-term property evaluations, long-term property evaluations, polymeric materials used in electrical equipment evaluations, industrial laminates, vulcanized fiber, materials used for printed wiring boards, filament wound tubing, flexible dielectric film materials, flammability, tracking, hot-wire ignition)

Material group and comparative tracking index (Comparative Tracking Index) Materials (tests specified in Annex A1 and A2) Materials used in high-voltage Components (tests specified in Annex A or in clause14.4 of IEC

  • OFF

OFF

Material group and comparative tracking index (Comparative Tracking Index): 2.10.4.2Materials (tests specified in Annex A1 and A2): 4.7.3Materials used in high-voltage Components (tests specified in Annex A or in clause14.4 of IEC: 4.7.3.6Voltage dependent resistors (VDRs) (Component flammability): Annex Q
  • Resistance to heat and fire testing
  • Thermoplastics testing (i.e. short-term property evaluations, long-term property evaluations, polymeric materials used in electrical equipment evaluations, industrial laminates, vulcanized fiber, materials used for printed wiring boards, filament wound tubing, flexible dielectric film materials, flammability, tracking, hot-wire ignition)

Material group and comparative tracking index (Comparative Tracking Index) Materials (tests specified in Annex A1 and A2) Materials used in high-voltage Components (tests specified in Annex A or in clause14.4 of IEC Voltage dependent resistors (VDRs) (Component flammability)

  • OFF