Wistron NeWeb Corporation

Address(es)
  • 20 Park Avenue II, Hsinchu Science Park,
    TW-300 Hsinchu
    Chinese Taipei

Website Not available
Status

MEMBER

Acceptance date 2023-09-26

Further information

Stage

Country

Name

2

Canada

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

ITAV

Accepted clauses:4.8.4, 4.8.5 Lithium coin/button cell batteries mechanical tests5.2 Classification of electrical energy sources5.4.1.4, 6.3.2, 9.0, B.2.6, Temperature measurements5.4.1.8 Determination of working voltage5.4.1.10.3 Ball pressure test of thermoplastics5.4.2.2, 5.4.2.4, 5.4.3 Minimum Clearances/Creepage distances5.4.2.3 Minimum clearances distances using required withstand voltage5.4.2.4 Clearances based on electric strength test5.4.4.2, 5.4.4.5 c), 5.4.4.9 Distance through insulation measurements5.4.8 Humidity conditioning5.4.9 Electric strength tests5.5.2.2 Stored discharge on capacitors5.6.6.2 Resistance of protective conductors and terminations5.7 Prospective touch voltage, touch current and protective conductor current5.7.2.2, 5.7.4 Earthed accessible conductive part5.7.7 Summation of touch currents from external circuits6.2.2 Electrical power sources (PS) measurements for classification6.2.3.1 Determination of Potential Ignition Sources (Arcing PIS)6.2.3.2 Determination of Potential Ignition Sources (Resistive PIS)8.2 Mechanical energy source classifications8.5 Fan blade classification8.6.2.2 Static stability8.6.5 Horizontal force8.7.2 Wall/Ceiling mount8.8 Handle strengthB.2.5 Input testB.3 Abnormal operating condition testsB.4 Fault condition testsAnnex M BatteriesAnnex M.4 Additional safeguards for equipment containing secondary lithium batteriesAnnex Q.1 Circuits intended for interconnection with building wiring (LPS)Annex Q.2 External circuits – paired conductor cableAnnexes T.2, T.3, T.4, T.5 Steady force testAnnexes T.6, T.9 Impact testsT.7 Drop testsT.8 Stress relief tests4.1.15, Annex F.3.9, F.3.10 Durability, legibility and permanence of markings
2022-04-25

ITAV

IEC 62368-1 - Accepted clauses: 4.8.4, 4.8.5, 5.2, 5.4.1.4, 6.3.2, 9.0, B.2.6, 5.4.1.8, 5.4.1.10.3, 5.4.2.2, 5.4.2.4, 5.4.3, 5.4.2.3, 5.4.2.4, 5.4.4.2, 5.4.4.5 c), 5.4.4.9, 5.4.8, 5.4.9, 5.5.2.2, 5.6.6.2, 5.7, 5.7.2.2, 5.7.4, 5.7.7, 6.2.2, 6.2.3.1, 6.2.3.2, 8.2, 8.5, 8.6.2.2, 8.6.5, 8.7.2, 8.8, B.2.5, B.3, B.4, Annex M, Annex M.4, Annex Q.1, Annex Q.2, Annexes T.2, T.3, T.4, T.5, Annexes T.6, T.9, T.7, T.8, 4.1.15, Annex F.3.9, F.3.10
2018-08-03

OFF

IEC 60950-1 - Accepted clauses: 1.6.2, 1.7.11, 2.1.1.5, 2.1.1.7, 2.2.2, 2.2.3, 2.2.4, 2.4.1, 2.4.2, 2.5, 2.6.3.4, 2.6.1, 2.9.1, 2.9.2, 5.2.2, 2.10.2, 2.10.5, 2.10.5.13, 4.1, 4.2, 4.3.1, 4.3.2, 4.3.6, 4.3.8, 4.4, 4.5.1, 1.4.12,1.4.13, 4.5.5, 4.5, 5.1, 5.2, 5.3, 6.1.2, 6.2.2(6.2.2.2), 7.3, 6.2.2, 6.2.2.2, 7.4.2
2020-08-03

OFF

IEC 60950-1 - Accepted clauses: 1.6.2, 1.7.11, 2.1.1.5, 2.1.1.7, 2.2.2, 2.2.3, 2.2.4, 2.4.1, 2.4.2, 2.5, 2.6.3.4, 2.6.1, 2.9.1, 2.9.2, 5.2.2, 2.10.2, 2.10.5, 2.10.5.13, 4.1, 4.2, 4.3.1, 4.3.2, 4.3.6, 4.3.8, 4.4, 4.5.1, 1.4.12,1.4.13, 4.5.5, 4.5, 5.1, 5.2, 5.3, 6.1.2, 6.2.2(6.2.2.2), 7.3, 6.2.2, 6.2.2.2, 7.4.2
2020-08-03

OFF

IEC 60950-1 - Accepted clauses: 1.6.2, 1.7.11, 2.1.1.5, 2.1.1.7, 2.2.2, 2.2.3, 2.2.4, 2.4.1, 2.4.2, 2.5, 2.6.3.4, 2.6.1, 2.9.1, 2.9.2, 5.2.2, 2.10.2, 2.10.5, 2.10.5.13, 4.1, 4.2, 4.3.1, 4.3.2, 4.3.6, 4.3.8, 4.4, 4.5.1, 1.4.12,1.4.13, 4.5.5, 4.5, 5.1, 5.2, 5.3, 6.1.2, 6.2.2(6.2.2.2), 7.3, 6.2.2, 6.2.2.2, 7.4.2
2020-08-03