Whirlpool Management EMEA S.r.l. ( Cooking laboratory )

Address(es)
  • Fraz. Marischio, Via Piani di Marischio, 48, 60044 Fabriano Ancona, ltaly
    Fabriano Ancona 60044
    Italy
    IT- 60044 Ancona
    Italy

Website Not available
Status

MEMBER

Acceptance date 2017-12-11

Further information

Stage

Country

Name

3

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

EMC

ALL
2018-12-31

HOUS

10 POWER INPUT AND CURRENT11 HEATING13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE15.2 MOISTURE RESISTANCE - SPILLAGE15.3 MOISTURE RESISTANCE - HUMIDITY16.2 LEAKAGE CURRENT AFTER HUMIDITY TREATMENT16.3 ELECTRIC STRENGTH AFTER HUMIDITY TREATMENT17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUIS19.10 ABNORMAL OPERATION - SERIES MOTOR19.11.1 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - LOW POWER CIRCUIT19.11.2 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - FAULT CONDITIONS19.11.3 ABNORMAL OPERATION - PROTECTIVE ELECTRONIC CIRCUIT19.12 ABNORMAL OPERATION - MINIATURE FUSE-LINK19.14 ABNORMAL OPERATION - CONTACTOR OR RELAY SHORT CIRCUIT19.2 ABNORMAL OPERATION - UNDER VOLTAGE & RESTRICTED HEAT DISSIPATION19.3 ABNORMAL OPERATION - OVER VOLTAGE & RESTRICTED HEAT DISSIPATION19.4 ABNORMAL OPERATION - SHORT CIRCUIT OF TEMPERATURE CONTROLS19.5 ABNORMAL OPERATION - TUBULAR SHEATHED OR EMBEDDED HEATING ELEMENTS19.6 ABNORMAL OPERATION - PTC HEATING ELEMENTS19.7 ABNORMAL OPERATION - STALLED CONDITIONS19.8 ABNORMAL OPERATION – DISCONNECTED PHASE20.1 STABILITY AND MECHANICAL HAZARDS - STABILITY20.2 STABILITY AND MECHANICAL HAZARDS - MECHANICAL FORCE21.1 MECHANICAL STRENGTH - SPRING HAMMER TEST22.11 CONSTRUCTION - RELIABILITY OF NON-DETACHABLE PARTS FIXING22.12 CONSTRUCTION - HANDLES, KNOBS, GRIPS, LEVERS - AXIAL PULL22.13 CONSTRUCTION - HANDLES - TEMPERATURE RISE22.42 CONSTRUCTION - PROTECTIVE IMPEDANCE22.5 CONSTRUCTION - CAPACITOR DISCHARGE TEST22.6 CONSTRUCTION - LEAKAGE OF LIQUID23.3 INTERNAL WIRING - MOVABLE PARTS WIRE FLEXING23.5 INTERNAL WIRING - ELECTRIC STRENGTH TEST24.5 COMPONENT - VOLTAGE ACROSS CAPACITOR25.15, 25.16 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS - PUSH, PULL & TORQUE TESTS FOR FLEXIBLE CORD25.2 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS - ELECTRIC STRENGTH TEST FOR MULTIPLE SUPPLY26.10 TERMINALS FOR EXTERNAL CONDUCTORS – CONNECTION TERMINALS FOR FLAT TWIN TINSEL CORDS26.3 TERMINALS FOR EXTERNAL CONDUCTORS - TERMINAL SECUREMENT TEST26.5 TERMINALS FOR EXTERNAL CONDUCTORS – STRANDED CONDUCTOR27.5 PROVISION FOR EARTHING - VOLTAGE DROP28.1 SCREWS AND CONNECTIONS - SCREW TORQUE TEST29.1, 29.2 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION - STEADY FORCE ON INTERNAL BARE CONDUCTORS 29.3.2 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION – ELECTRIC STRENGTH TEST ON INSULATION LAYERS30.1 RESISTANCE TO HEAT AND FIRE - BALL PRESSURE TEST30.2 RESISTANCE TO HEAT AND FIRE - GLOW-WIRE TEST30.2.3.2, ANNEX E RESISTANCE TO HEAT AND FIRE - NEEDLE FLAME TEST5 GENERAL CONDITIONS FOR THE TESTS7.14 MARKING AND INSTRUCTIONS - MARKING DURABILITY8.1.1 PROTECTION AGAINST ACCESS TO LIVE PARTS - TEST PROBE B OF IEC610328.1.2 PROTECTION AGAINST ACCESS TO LIVE PARTS - TEST PROBE 13 OF IEC610328.1.3 PROTECTION AGAINST ACCESS TO LIVE PARTS - TEST PROBE 41 OF IEC610328.1.4 PROTECTION AGAINST ACCESS TO LIVE PARTS - ACCESSIBLE PART - PROTECTIVE IMPEDANCE8.1.4 PROTECTION AGAINST ACCESS TO LIVE PARTS - ACCESSIBLE PART - SELVANNEX C AGEING TEST ON MOTORSANNEX D THERMAL MOTOR PROTECTORSANNEX G SAFETY ISOLATING TRANSFORMERSANNEX I MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED VOLTAGE OF THE APPLIANCEANNEX R SOFTWARE EVALUATION
2018-12-31

HOUS

10 POWER INPUT AND CURRENT11 HEATING13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE15.2 MOISTURE RESISTANCE - SPILLAGE15.3 MOISTURE RESISTANCE - HUMIDITY16.2 LEAKAGE CURRENT AFTER HUMIDITY TREATMENT16.3 ELECTRIC STRENGTH AFTER HUMIDITY TREATMENT17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUIS19.10 ABNORMAL OPERATION - SERIES MOTOR19.11.1 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - LOW POWER CIRCUIT19.11.2 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - FAULT CONDITIONS19.11.3 ABNORMAL OPERATION - PROTECTIVE ELECTRONIC CIRCUIT19.12 ABNORMAL OPERATION - MINIATURE FUSE-LINK19.14 ABNORMAL OPERATION - CONTACTOR OR RELAY SHORT CIRCUIT19.2 ABNORMAL OPERATION - UNDER VOLTAGE & RESTRICTED HEAT DISSIPATION19.3 ABNORMAL OPERATION - OVER VOLTAGE & RESTRICTED HEAT DISSIPATION19.4 ABNORMAL OPERATION - SHORT CIRCUIT OF TEMPERATURE CONTROLS19.5 ABNORMAL OPERATION - TUBULAR SHEATHED OR EMBEDDED HEATING ELEMENTS19.6 ABNORMAL OPERATION - PTC HEATING ELEMENTS19.7 ABNORMAL OPERATION - STALLED CONDITIONS19.8 ABNORMAL OPERATION – DISCONNECTED PHASE20.1 STABILITY AND MECHANICAL HAZARDS - STABILITY20.2 STABILITY AND MECHANICAL HAZARDS - MECHANICAL FORCE21.1 MECHANICAL STRENGTH - SPRING HAMMER TEST22.11 CONSTRUCTION - RELIABILITY OF NON-DETACHABLE PARTS FIXING22.12 CONSTRUCTION - HANDLES, KNOBS, GRIPS, LEVERS - AXIAL PULL22.13 CONSTRUCTION - HANDLES - TEMPERATURE RISE22.42 CONSTRUCTION - PROTECTIVE IMPEDANCE22.5 CONSTRUCTION - CAPACITOR DISCHARGE TEST22.6 CONSTRUCTION - LEAKAGE OF LIQUID23.3 INTERNAL WIRING - MOVABLE PARTS WIRE FLEXING23.5 INTERNAL WIRING - ELECTRIC STRENGTH TEST24.5 COMPONENT - VOLTAGE ACROSS CAPACITOR25.15, 25.16 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS - PUSH, PULL & TORQUE TESTS FOR FLEXIBLE CORD25.2 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS - ELECTRIC STRENGTH TEST FOR MULTIPLE SUPPLY26.10 TERMINALS FOR EXTERNAL CONDUCTORS – CONNECTION TERMINALS FOR FLAT TWIN TINSEL CORDS26.3 TERMINALS FOR EXTERNAL CONDUCTORS - TERMINAL SECUREMENT TEST26.5 TERMINALS FOR EXTERNAL CONDUCTORS – STRANDED CONDUCTOR27.5 PROVISION FOR EARTHING - VOLTAGE DROP28.1 SCREWS AND CONNECTIONS - SCREW TORQUE TEST29.1, 29.2 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION - STEADY FORCE ON INTERNAL BARE CONDUCTORS 29.3.2 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION – ELECTRIC STRENGTH TEST ON INSULATION LAYERS30.1 RESISTANCE TO HEAT AND FIRE - BALL PRESSURE TEST30.2 RESISTANCE TO HEAT AND FIRE - GLOW-WIRE TEST30.2.3.2, ANNEX E RESISTANCE TO HEAT AND FIRE - NEEDLE FLAME TEST5 GENERAL CONDITIONS FOR THE TESTS7.14 MARKING AND INSTRUCTIONS - MARKING DURABILITY8.1.1 PROTECTION AGAINST ACCESS TO LIVE PARTS - TEST PROBE B OF IEC610328.1.2 PROTECTION AGAINST ACCESS TO LIVE PARTS - TEST PROBE 13 OF IEC610328.1.3 PROTECTION AGAINST ACCESS TO LIVE PARTS - TEST PROBE 41 OF IEC610328.1.4 PROTECTION AGAINST ACCESS TO LIVE PARTS - ACCESSIBLE PART - PROTECTIVE IMPEDANCE8.1.4 PROTECTION AGAINST ACCESS TO LIVE PARTS - ACCESSIBLE PART - SELVANNEX C AGEING TEST ON MOTORSANNEX D THERMAL MOTOR PROTECTORSANNEX G SAFETY ISOLATING TRANSFORMERSANNEX I MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED VOLTAGE OF THE APPLIANCEANNEX R SOFTWARE EVALUATION
2018-12-31

HOUS

10 POWER INPUT AND CURRENT11 HEATING13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE15.2 MOISTURE RESISTANCE - SPILLAGE15.3 MOISTURE RESISTANCE - HUMIDITY16.2 LEAKAGE CURRENT AFTER HUMIDITY TREATMENT16.3 ELECTRIC STRENGTH AFTER HUMIDITY TREATMENT17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUIS19.10 ABNORMAL OPERATION - SERIES MOTOR19.11.1 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - LOW POWER CIRCUIT19.11.2 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - FAULT CONDITIONS19.11.3 ABNORMAL OPERATION - PROTECTIVE ELECTRONIC CIRCUIT19.12 ABNORMAL OPERATION - MINIATURE FUSE-LINK19.14 ABNORMAL OPERATION - CONTACTOR OR RELAY SHORT CIRCUIT19.2 ABNORMAL OPERATION - UNDER VOLTAGE & RESTRICTED HEAT DISSIPATION19.3 ABNORMAL OPERATION - OVER VOLTAGE & RESTRICTED HEAT DISSIPATION19.4 ABNORMAL OPERATION - SHORT CIRCUIT OF TEMPERATURE CONTROLS19.5 ABNORMAL OPERATION - TUBULAR SHEATHED OR EMBEDDED HEATING ELEMENTS19.6 ABNORMAL OPERATION - PTC HEATING ELEMENTS19.7 ABNORMAL OPERATION - STALLED CONDITIONS19.8 ABNORMAL OPERATION – DISCONNECTED PHASE20.1 STABILITY AND MECHANICAL HAZARDS - STABILITY20.2 STABILITY AND MECHANICAL HAZARDS - MECHANICAL FORCE21.1 MECHANICAL STRENGTH - SPRING HAMMER TEST22.11 CONSTRUCTION - RELIABILITY OF NON-DETACHABLE PARTS FIXING22.12 CONSTRUCTION - HANDLES, KNOBS, GRIPS, LEVERS - AXIAL PULL22.13 CONSTRUCTION - HANDLES - TEMPERATURE RISE22.42 CONSTRUCTION - PROTECTIVE IMPEDANCE22.5 CONSTRUCTION - CAPACITOR DISCHARGE TEST22.6 CONSTRUCTION - LEAKAGE OF LIQUID23.3 INTERNAL WIRING - MOVABLE PARTS WIRE FLEXING23.5 INTERNAL WIRING - ELECTRIC STRENGTH TEST24.5 COMPONENT - VOLTAGE ACROSS CAPACITOR25.15, 25.16 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS - PUSH, PULL & TORQUE TESTS FOR FLEXIBLE CORD25.2 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS - ELECTRIC STRENGTH TEST FOR MULTIPLE SUPPLY26.10 TERMINALS FOR EXTERNAL CONDUCTORS – CONNECTION TERMINALS FOR FLAT TWIN TINSEL CORDS26.3 TERMINALS FOR EXTERNAL CONDUCTORS - TERMINAL SECUREMENT TEST26.5 TERMINALS FOR EXTERNAL CONDUCTORS – STRANDED CONDUCTOR27.5 PROVISION FOR EARTHING - VOLTAGE DROP28.1 SCREWS AND CONNECTIONS - SCREW TORQUE TEST29.1, 29.2 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION - STEADY FORCE ON INTERNAL BARE CONDUCTORS 29.3.2 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION – ELECTRIC STRENGTH TEST ON INSULATION LAYERS30.1 RESISTANCE TO HEAT AND FIRE - BALL PRESSURE TEST30.2 RESISTANCE TO HEAT AND FIRE - GLOW-WIRE TEST30.2.3.2, ANNEX E RESISTANCE TO HEAT AND FIRE - NEEDLE FLAME TEST5 GENERAL CONDITIONS FOR THE TESTS7.14 MARKING AND INSTRUCTIONS - MARKING DURABILITY8.1.1 PROTECTION AGAINST ACCESS TO LIVE PARTS - TEST PROBE B OF IEC610328.1.2 PROTECTION AGAINST ACCESS TO LIVE PARTS - TEST PROBE 13 OF IEC610328.1.3 PROTECTION AGAINST ACCESS TO LIVE PARTS - TEST PROBE 41 OF IEC610328.1.4 PROTECTION AGAINST ACCESS TO LIVE PARTS - ACCESSIBLE PART - PROTECTIVE IMPEDANCE8.1.4 PROTECTION AGAINST ACCESS TO LIVE PARTS - ACCESSIBLE PART - SELVANNEX C AGEING TEST ON MOTORSANNEX D THERMAL MOTOR PROTECTORSANNEX G SAFETY ISOLATING TRANSFORMERSANNEX I MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED VOLTAGE OF THE APPLIANCEANNEX R SOFTWARE EVALUATION
2018-12-31

HOUS

10 POWER INPUT AND CURRENT11 HEATING13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE 15 MOISTURE RESISTANCE 15.101 MOISTURE RESISTANCE - TEMPERATURE SENSING PROBES16 LEAKAGE CURRENT AND ELECTRIC STRENGTH17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS19 ABNORMAL OPERATION20 STABILITY AND MECHANICAL HAZARDS20.101 STABILITY AND MECHANICAL HAZARDS - DOORS20.102 STABILITY AND MECHANICAL HAZARDS - DOORS WITH A HINGE HEIGHT LESS THAN 430 MM21 MECHANICAL STRENGTH 21.101 MECHANICAL STRENGTH - OVEN SHELVES21.102 MECHANICAL STRENGTH - HOB SURFACES21.103 MECHANICAL STRENGTH - TEMPERATURE SENSING PROBES21.104 MECHANICAL STRENGTH - GLASS PANELS22 CONSTRUCTION22.108 CONSTRUCTION - PYROLYTIC SELF-CLEANING OVENS22.109 CONSTRUCTION - PYROLYTIC SELF-CLEANING OVENS WITH INTERLOCK22.112 CONSTRUCTION - HINGED LIDS22.113 CONSTRUCTION - HOBS WITH TOUCH CONTROLS22.114 CONSTRUCTION - HOB ELEMENTS - TWO MANUAL OPERATIONS TO SWITCH ON, ONE MANUAL OPERATION TO SWITCH OFF22.115 CONSTRUCTION - INDUCTION ELEMENTS AND PAN DETECTOR OPERATION22.116 CONSTRUCTION - INDUCTION ELEMENTS AND PAN DETECTOR TIMEOUT22.120 CONSTRUCTION - GLASS FRACTURE TEST22.121 CONSTRUCTION - REMOVABLE GLASS PANELS 22.122 CONSTRUCTION - WITHDRAWABLE SHELVES22.138 CONSTRUCTION - POWER MANAGEMENT FAULT CONDITION23 INTERNAL WIRING24 COMPONENTS24.101 COMPONENTS - THERMOSTATS25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS26 TERMINALS FOR EXTERNAL CONDUCTORS 27 PROVISION FOR EARTHING28 SCREWS AND CONNECTIONS ANNEX C AGEING TEST ON MOTORSANNEX D THERMAL MOTOR PROTECTORSANNEX E NEEDLE-FLAME TESTANNEX G SAFETY ISOLATING TRANSFORMERSANNEX I MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED VOLTAGE OF THE APPLIANCEANNEX R SOFTWARE EVALUATION29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION30 RESISTANCE TO HEAT AND FIRE32 RADIATION, TOXICITY AND SIMILAR HAZARDS 5 GENERAL CONDITIONS FOR THE TESTS 7 MARKING AND INSTRUCTIONS8 PROTECTION AGAINST ACCESS TO LIVE PARTS
2018-12-31

HOUS

10 POWER INPUT AND CURRENT11 HEATING13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE 15 MOISTURE RESISTANCE 15.101 MOISTURE RESISTANCE - TEMPERATURE SENSING PROBES16 LEAKAGE CURRENT AND ELECTRIC STRENGTH17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS19 ABNORMAL OPERATION20 STABILITY AND MECHANICAL HAZARDS20.101 STABILITY AND MECHANICAL HAZARDS - DOORS20.102 STABILITY AND MECHANICAL HAZARDS - DOORS WITH A HINGE HEIGHT LESS THAN 430 MM21 MECHANICAL STRENGTH 21.101 MECHANICAL STRENGTH - OVEN SHELVES21.102 MECHANICAL STRENGTH - HOB SURFACES21.103 MECHANICAL STRENGTH - TEMPERATURE SENSING PROBES21.104 MECHANICAL STRENGTH - GLASS PANELS22 CONSTRUCTION22.108 CONSTRUCTION - PYROLYTIC SELF-CLEANING OVENS22.109 CONSTRUCTION - PYROLYTIC SELF-CLEANING OVENS WITH INTERLOCK22.112 CONSTRUCTION - HINGED LIDS22.113 CONSTRUCTION - HOBS WITH TOUCH CONTROLS22.114 CONSTRUCTION - HOB ELEMENTS - TWO MANUAL OPERATIONS TO SWITCH ON, ONE MANUAL OPERATION TO SWITCH OFF22.115 CONSTRUCTION - INDUCTION ELEMENTS AND PAN DETECTOR OPERATION22.116 CONSTRUCTION - INDUCTION ELEMENTS AND PAN DETECTOR TIMEOUT22.120 CONSTRUCTION - GLASS FRACTURE TEST22.121 CONSTRUCTION - REMOVABLE GLASS PANELS 22.122 CONSTRUCTION - WITHDRAWABLE SHELVES22.138 CONSTRUCTION - POWER MANAGEMENT FAULT CONDITION23 INTERNAL WIRING24 COMPONENTS24.101 COMPONENTS - THERMOSTATS25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS26 TERMINALS FOR EXTERNAL CONDUCTORS 27 PROVISION FOR EARTHING28 SCREWS AND CONNECTIONS ANNEX C AGEING TEST ON MOTORSANNEX D THERMAL MOTOR PROTECTORSANNEX E NEEDLE-FLAME TESTANNEX G SAFETY ISOLATING TRANSFORMERSANNEX I MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED VOLTAGE OF THE APPLIANCEANNEX R SOFTWARE EVALUATION29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION30 RESISTANCE TO HEAT AND FIRE32 RADIATION, TOXICITY AND SIMILAR HAZARDS 5 GENERAL CONDITIONS FOR THE TESTS 7 MARKING AND INSTRUCTIONS8 PROTECTION AGAINST ACCESS TO LIVE PARTS
2018-12-31

HOUS

10 POWER INPUT AND CURRENT11 HEATING13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE15 MOISTURE RESISTANCE15.2 SPILLAGE TEST16 LEAKAGE CURRENT AND ELECTRIC STRENGTH17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS19 ABNORMAL OPERATION20 STABILITY AND MECHANICAL HAZARDS21 MECHANICAL STRENGTH22 CONSTRUCTION22.103 AGING CAUSED BY PARTIAL DISCHARGE 24 COMPONENTS25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS26 TERMINALS FOR EXTERNAL CONDUCTORS27 PROVISION FOR EARTHING28 SCREWS AND CONNECTIONS29 CLEARANCE, CREEPAGE DISTANCES AND SOLID INSULATION30 RESISTANCE TO HEAT AND FIRE8.101 ACCESSIBILE SPARK-IGNITION CIRCUIT LIMITS
2018-12-31