Vaisala Oyj

Address(es)
  • Vanha Nurmijärventie 21
    FI-01670 Vantaa
    Finland

Website Not available
Status

MEMBER

Acceptance date 2021-12-01

Further information

Stage

Country

Name

1

Finland

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

ITAV

Accepted Clauses4.1.15 (Annex F.3.10) Permanence of Marking Test4.4.3.2 (Annex T.2 – T.5) Steady Force Test4.4.3.3 (Annex T.7) Drop test4.4.3.4 (T.6) Impact test, no plastic enclosures used for outdoor EUT5.2 Electrical energy source classifications5.3.2.4 (Annex V.1.6) Test of the terminals for connecting stripped wire5.4.1.4 & 9.2.6 Maximum operating temperature for insulating materials Temperatures on Accessible Surfaces5.4.1.8 Working voltage measurement5.4.2, 5.4.3, 5.4.4.5 a), b) Minimum Clearances/Creepage distance5.4.4 Solid Insulation Measurement5.4.9 Electric Strength test5.4.11 Separation of the telecommunication network from earth5.5.2.2 Safeguards against capacitor discharge5.6.6 Protective Earth Resistance Test5.7 Touch current6.2 Power source circuit classifications6.4 (Annex B.3-B.4) Single fault conditions8.5 Safeguards against moving parts8.6.2.2 Static stability test8.6.2.3 Downward force test8.6.3 Relocation stability test8.7 Wall/Ceiling Mounting Means Test8.8 Handle strength test8.9 Wheels or casters attachment Test8.10 Carts, stands and similar carriersAnnex B.2.5 Input testAnnex G.5.4.3 Running overload testAnnex G.5.4.4 Locked-rotor overload testAnnex G.5.4.5 Running overload test for d.c. motorsAnnex G.5.4.6 Locked-rotor overload test for d.c. motorsAnnex G.5.4.9 Compliance and test method for series motorsAnnex G.7.3 Cord anchorages and strain relief testAnnex G.7.6.2 Stranded wireAnnex K Safety Interlocks (verification by data only)Annex Q.1 Circuits intended for interconnection with building wiring (LPS).
2021-12-01

MEAS

Accepted Clauses4.3.1 Temperature, Humidity, Air pressure4.3.2.5 / 5.1.3 Input Voltage, Input Current / Power, Input frequency4.4.2 Application of fault conditions4.4.4.2 Temperature measurements4.4.4.3 Spread of fire5.3 Durability of markings6.1.1 / 6.3 / 6.10.3 Residual Energy6.2 Accessibility6.3 Accessible voltage / current / capacitance / stored energy6.5.2 Protective bonding / bonding impedance / earth continuity test6.5.4 Protective impedance6.6.2 / 6.10.3 Terminals for external circuits(capacitive discharge test)6.7 Clearance & creepage distances excluding 6.7.1.36.8.1 Distances between Terminal and foil6.8.3 Dielectric strength tests6.10.2.1 Cord entry test6.10.2.2 Cord anchorage test7.2 Sharp edges7.3.4 Limitation of force and pressure7.3.5 Gap limitations between moving parts7.4 Stability tests7.5 Strength of handles7.6 Wall mounting8.2.1 Static test8.2.2 Impact test, no plastic enclosures used8.3.1 Drop test8.3.2 Hand-held equipment9.3.1 / 14.7 Flammability tests (verification by data only)9.3.2 Constructional requirements (verification by data only)9.4 Limited Energy Circuits10.4.1 Conduct of temperature tests10.5.3 Insulating materials (verification by data only)11.2 Cleaning / decontamination11.3 Spillage11.4 (6.8.4) Overflow11.6.3 Protection against solid foreign objectslimited to IP1X, 2X, 3X, 4X12.2.1 Ionizing radiation, radiation measurements shall be performed before CTF testing. 12.3 UV Radiation (verification by data only)12.6 Laser sources (verification by data only)13.2.2 Batteries and battery charging14.2 Motors14.3 Over temperature protection devices14.4 Fuse holders14.5 MAINS voltage selection devices14.6 Mains transformers tested outside equipment15 Protection by Interlocks (cycling test excluded)16 Reasonably foreseeable misuse.
2021-12-01

MEAS

Accepted Clauses4.3.1 Temperature, Humidity, Air pressure4.3.2.5 / 5.1.3 Input Voltage, Input Current / Power, Input frequency4.4.2 Application of fault conditions4.4.4.2 Temperature measurements4.4.4.3 Spread of fire5.3 Durability of markings6.1.1 / 6.3 / 6.10.3 Residual Energy6.2 Accessibility6.3 Accessible voltage / current / capacitance / stored energy6.5.2 Protective bonding / bonding impedance / earth continuity test6.5.4 Protective impedance6.6.2 / 6.10.3 Terminals for external circuits(capacitive discharge test)6.7 Clearance & creepage distances excluding 6.7.1.36.8.1 Distances between Terminal and foil6.8.3 Dielectric strength tests6.10.2.1 Cord entry test6.10.2.2 Cord anchorage test7.2 Sharp edges7.3.4 Limitation of force and pressure7.3.5 Gap limitations between moving parts7.4 Stability tests7.5 Strength of handles7.6 Wall mounting8.2.1 Static test8.2.2 Impact test, no plastic enclosures used8.3.1 Drop test8.3.2 Hand-held equipment9.3.1 / 14.7 Flammability tests (verification by data only)9.3.2 Constructional requirements (verification by data only)9.4 Limited Energy Circuits10.4.1 Conduct of temperature tests10.5.3 Insulating materials (verification by data only)11.2 Cleaning / decontamination11.3 Spillage11.4 (6.8.4) Overflow11.6.3 Protection against solid foreign objectslimited to IP1X, 2X, 3X, 4X12.2.1 Ionizing radiation, radiation measurements shall be performed before CTF testing. 12.3 UV Radiation (verification by data only)12.6 Laser sources (verification by data only)13.2.2 Batteries and battery charging14.2 Motors14.3 Over temperature protection devices14.4 Fuse holders14.5 MAINS voltage selection devices14.6 Mains transformers tested outside equipment15 Protection by Interlocks (cycling test excluded)16 Reasonably foreseeable misuse.
2021-12-01