Danfoss Drives Oy (Vaasa)

Address(es)
  • Runsorintie 7
    FIN-65380 Vaasa
    Finland

Website Not available
Status

MEMBER

Acceptance date 2016-03-08

Further information

Stage

Country

Name

2

Finland

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

EMC

Accepted clauses: 5.3.2 Immunity requirements, First environment (only surge test) and 5.3.3 Immunity requirements, Second environment (only surge test).
2016-03-08

EMC

Accepted clauses: Table 11 Immunity requirements, First environment (only surge test) and Table 12 Immunity requirements, Second environment (only surge test).
2016-03-08

INST

Accepted clauses: 5.2.2.2 PWB short-circut test, 5.2.3.1 Impulse voltage (max. 15kV, only with external HV probe), 5.2.3.2 A.C. or D.C. voltage, 5.2.3.6.3 Short-circuit test (max. 20 kA at 690 V depending on test place), 5.2.3.6.4 Breakdown of components, 5.2.3.7 Capacitor discharge, 5.2.3.8 Temperature rise, 5.2.3.9 Temperature rise, 5.2.4.4 Loss of phase, 5.2.4.5.2 Inoperative blower, 5.2.4.5.3 Clogged filter, 5.2.4.5.4 Loss of coolant, 5.2.6.3.1 Dry heat, 5.2.6.3.2 Damp heat and 5.2.7 Hydrostatic pressure.
2016-03-08

INST

Accepted clauses: 5.2.8 Electronic motor overload protection test
2021-03-25

INST

Accepted clauses: 5.2.3.2 Impulse voltage (max. 15 kV, only with external HV probe), 5.2.3.4 a.c. or d.c. Voltage test, 5.2.3.8 Capacitor discharge test, 5.2.3.9 Limited power source test [NCR 4], 5.2.3.10 Temperature rise test, 5.2.3.11.2 Protective equipotential bonding impedance test, 5.2.4.4 Output short circuit test (max 20kA at 690V depending on test place), 5.2.4.5 Output overload test, 5.2.4.6 Breakdown of component test, 5.2.4.7 PWB short circuit test, 5.2.4.8 Loss of phase test, 5.2.4.9 Cooling Failure Test, 5.2.4.9.2 Inoperative blower test, 5.2.4.9.3 Clogged filter test, 5.2.4.9.4 Loss of coolant test, 5.2.6.3.1 Dry Heat test and 5.2.7 Hydrostatic pressure test.
2020-05-05

INST

5.2.4.4 Output short circuit test (max. 20 kA at 690 V depending on test place), 5.2.4.5 Output overload test,5.2.4.6 Breakdown of components test, 5.2.4.7 PWB short circuit test, 5.2.4.8 Loss of phase test, 5.2.4.9 Cooling Failure tests,5.2.4.9.2 Inoperative blower test, 5.2.4.9.3 Clogged filter test, 5.2.4.9.4 Loss of coolant test.
2022-05-30