Trumpf Huettinger Sp. z o.o. (23054)
Trumpf Huettinger Sp. z o.o. (23054)
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2024-01-24 |
Further information
Stage | Country | Name |
---|---|---|
2 | Sweden |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
MEAS | IEC 61010-1:2010 | Accepted Clauses for CTF 1 (not for LSV video)Durability of Marking 5.3List of accessible parts 6.2Leakage current in normal condition 6.3.1Leakage current in single fault condition 6.3.2Cross-sectional area of bonding conductors 6.5.2.2Tightening torque test 6.5.2.3Bonding impedance of plug-connected equipment 6.5.2.4Bonding impedance of Permanently Connected Equipment 6.5.2.5Current- or voltage-limiting devices 6.5.6Insulation requirements – Block diagram of system 6.7Insulation requirements – Clearance and Creepages measurements 6.7Insulation requirements – Clearance and Creepages measurements after mechanical and temperature stresses 6.7Stability 7.4Wall mounting 7.6Mechanical resistance to shock and impact 8.0Enclosure rigidity test: Static test 8.2.1Enclosure rigidity test: Impact test 8.2.2Drop test: Other equipment 8.3.1Protection against the spread of fire 9.0Constructional requirements 9.3.2Limited-energy circuit 9.4Protection against hazards from fluids and solid foreign objects 11.0Sound level 12.5.1Overtemperature protection devices 14.3Accepted Clauses for CTF 2 (for LSV video)Testing in single fault condition 4.4Input test 5.1.3c)Tightening torque test 6.5.2.3Bonding impedance of plug-connected equipment 6.5.2.4Bonding impedance of Permanently Connected Equipment 6.5.2.5 Connection for external circuit 6.6Procedure for voltage testes 6.8Humidity preconditioning 6.8.2Leakage and rupture at high pressure 11.7.2 | 2024-01-24 | |
MEAS | IEC 61010-1:2010/AMD1:2016 | Accepted Clauses for CTF 1 (not for LSV video)Durability of Marking 5.3List of accessible parts 6.2Leakage current in normal condition 6.3.1Leakage current in single fault condition 6.3.2Cross-sectional area of bonding conductors 6.5.2.2Tightening torque test 6.5.2.3Bonding impedance of plug-connected equipment 6.5.2.4Bonding impedance of Permanently Connected Equipment 6.5.2.5Current- or voltage-limiting devices 6.5.6Insulation requirements – Block diagram of system 6.7Insulation requirements – Clearance and Creepages measurements 6.7Insulation requirements – Clearance and Creepages measurements after mechanical and temperature stresses 6.7Stability 7.4Wall mounting 7.6Mechanical resistance to shock and impact 8.0Enclosure rigidity test: Static test 8.2.1Enclosure rigidity test: Impact test 8.2.2Drop test: Other equipment 8.3.1Protection against the spread of fire 9.0Constructional requirements 9.3.2Limited-energy circuit 9.4Protection against hazards from fluids and solid foreign objects 11.0Sound level 12.5.1Overtemperature protection devices 14.3Accepted Clauses for CTF 2 (for LSV video)Testing in single fault condition 4.4Input test 5.1.3c)Tightening torque test 6.5.2.3Bonding impedance of plug-connected equipment 6.5.2.4Bonding impedance of Permanently Connected Equipment 6.5.2.5 Connection for external circuit 6.6Procedure for voltage testes 6.8Humidity preconditioning 6.8.2Leakage and rupture at high pressure 11.7.2 | 2024-01-24 |