TDK-LAMBDA AMERICAS INC.

Address(es)
  • 3000 Technology Dr. Suite 100
    Plano 75074
    Texas
    United States of America

Website Not available
Status

MEMBER

Acceptance date 2024-01-19

Further information

Stage

Country

Name

1

United States of America

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

ITAV

B.2.5 - Input Test: Single Phase5.4.8 – Humidity Test5.4.1.5, 9.4.1.2 - Heating Test5.4.9.1 – Electric Strength TestB.3 - Abnormal Operating Condition TestsB.3.5 - Power Supply Output Short‐Circuit/Overload B.4 - Component FailureB.2.5 - Input Test: Single Phase5.4.8 – Humidity TestB.2.6, 9.4.1.2 - Heating Test5.4.9.1 – Electric Strength TestB.3 - Abnormal Operating Condition TestsB.3.5 - Power Supply Output Short‐Circuit/Overload B.4 – Simulated Single Fault
2024-01-19

ITAV

B.2.5 - Input Test: Single Phase5.4.8 – Humidity Test5.4.1.5, 9.4.1.2 - Heating Test5.4.9.1 – Electric Strength TestB.3 - Abnormal Operating Condition TestsB.3.5 - Power Supply Output Short‐Circuit/Overload B.4 - Component FailureB.2.5 - Input Test: Single Phase5.4.8 – Humidity TestB.2.6, 9.4.1.2 - Heating Test5.4.9.1 – Electric Strength TestB.3 - Abnormal Operating Condition TestsB.3.5 - Power Supply Output Short‐Circuit/Overload B.4 – Simulated Single Fault
2024-01-19

OFF

1.6.2 - Input Test: Single-Phase2.5 - Limited Power Source Measurements2.6.3.4, 2.6.1 - Earthing Test I4.5.1, 1.4.12, 1.4.13, 3.3.2 - Heating (Temperature) Test5.1, Annex D - Touch Current Test (Single-Phase/ Polyphase; TN/TT System)5.2.2 - Electric Strength Test5.3.1-5.3.9.2 - Abnormal Operation Tests5.3.7 - Overload of Operator Accessible Connector Test
2024-01-19

OFF

1.6.2 - Input Test: Single-Phase2.5 - Limited Power Source Measurements2.6.3.4, 2.6.1 - Earthing Test I4.5.1, 1.4.12, 1.4.13, 3.3.2 - Heating (Temperature) Test5.1, Annex D - Touch Current Test (Single-Phase/ Polyphase; TN/TT System)5.2.2 - Electric Strength Test5.3.1-5.3.9.2 - Abnormal Operation Tests5.3.7 - Overload of Operator Accessible Connector Test
2024-01-19

OFF

1.6.2 - Input Test: Single-Phase2.5 - Limited Power Source Measurements2.6.3.4, 2.6.1 - Earthing Test I4.5.1, 1.4.12, 1.4.13, 3.3.2 - Heating (Temperature) Test5.1, Annex D - Touch Current Test (Single-Phase/ Polyphase; TN/TT System)5.2.2 - Electric Strength Test5.3.1-5.3.9.2 - Abnormal Operation Tests5.3.7 - Overload of Operator Accessible Connector Test
2024-01-19