Skanray Technologies Limited
Skanray Technologies Limited
Address(es) |
|
Website | Not available |
Status | WITHDRAWN |
Acceptance date | 2016-04-05 |
Further information
Stage | Country | Name |
---|---|---|
1 | Denmark |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
MED | IEC 60601-1:2005 | 4.11, 5.7, 5.9.2, 7.1.2, 7.1.3, 8.4.4, 8.5.4, 8.6.4 a, 8.7, 8.7.4.5, 8.7.4.6, 8.7.4.7 a), 8.7.3 e), 8.8.3, 8.11.3.5, 8.11.4.2, 8.11.4.3, 9.2.2.2, 9.2.3.2, 9.6.2.1, 9.8.2, 9.8.3.1, 9.8.3.2, 9.8.3.3, 11, 11.6.3, 11.6.5, 11.6.6, 11.8, 13, 13.2, 13.2.13.3 b, 15.3.2, 15.3.3, 15.3.4, 15.4.6, 15.4.7.1 | 2022-11-18 | |
MED | IEC 60601-1:2005/AMD1:2012 | 4.11, 5.7, 5.9.2, 7.1.2, 7.1.3, 8.4.4, 8.5.4, 8.6.4 a, 8.7, 8.7.4.5, 8.7.4.6, 8.7.4.7 a), 8.7.3 e), 8.8.3, 8.11.3.5, 8.11.4.2, 8.11.4.3, 9.2.2.2, 9.2.3.2, 9.6.2.1, 9.8.2, 9.8.3.1, 9.8.3.2, 9.8.3.3, 11, 11.6.3, 11.6.5, 11.6.6, 11.8, 13, 13.2, 13.2.13.3 b, 15.3.2, 15.3.3, 15.3.4, 15.4.6, 15.4.7.1 | 2022-11-18 | |
MED | IEC 60601-1:2005/AMD2:2020 | 4.11, 5.7, 5.9.2, 7.1.2, 7.1.3, 8.4.4, 8.5.4, 8.6.4 a, 8.7, 8.7.4.5, 8.7.4.6, 8.7.4.7 a), 8.7.3 e), 8.8.3, 8.11.3.5, 8.11.4.2, 8.11.4.3, 9.2.2.2, 9.2.3.2, 9.6.2.1, 9.8.2, 9.8.3.1, 9.8.3.2, 9.8.3.3, 11, 11.6.3, 11.6.5, 11.6.6, 11.8, 13, 13.2, 13.2.13.3 b, 15.3.2, 15.3.3, 15.3.4, 15.4.6, 15.4.7.1 | 2022-11-18 | |
MED | IEC 60601-1-3:2008 | 8.5.2Measurement of Focal Spot to Image Receptor Distance,12.4 Leakage Radiation in Loading State,12.5 Leakage Radiation when not in Loading State, 7.1 HVL and total filtration, 7.6 Test for HVL | 2022-11-18 | |
MED | IEC 60601-1-3:2008/AMD1:2013 | 8.5.2Measurement of Focal Spot to Image Receptor Distance,12.4 Leakage Radiation in Loading State,12.5 Leakage Radiation when not in Loading State, 7.1 HVL and total filtration, 7.6 Test for HVL | 2022-11-18 | |
MED | IEC 60601-2-54:2009 | (201.4.10.2) Supply main for ME equipment,(201.8.5.4.101)Stator and Stator Circuit Dielectric Strength Testing,(201.8.7.3) Leakage Currents, 201.8.8.3 Dielectric Strength,201.11.102)PROTECTION AGAINST EXCESSIVE TEMPERATURES OF BEAM LIMITING DEVICES(203.4.101.2)PERCENTAGE RIPPLE IN CONSTANT POTENTIAL HIGH-VOLTAGE GENERATORS(203.6.3.2.101)REPRODUCIBILITY OF THE RADIATION OUTPUT IN RADIOGRAPHY203.6.3.2.102 A)LINEARITY OF AIR KERMA OVER LIMITED INTERVALS OF LOADING FACTORS(203.6.4.3.104.3)ACCURACY OF X-RAY TUBE VOLTAGE(203.6.4.3.104.4)ACCURACY OF X-RAY TUBE CURRENT(203.6.4.3.104.5)ACCURACY OF LOADING TIME(203.6.4.3.104.6)ACCURACY OF CURRENT TIME PRODUCT203.8.5.3)CORRESPONDENCE BETWEEN X-RAY FIELD AND IMAGE RECEPTION AREA(203.8.102)METHODS OF BEAM LIMITATION IN X-RAY EQUIPMENT(203.8.102.4)CCURACY OF MARKED AND WRITTEN INDICATIONS(203.8.102.5)INDICATION BY LIGHT FIELD-INDICATOR(203.9)(203.8.102.6)ACCURACY OF INDICATION WITH A LIGHT FIELD-INDICATOR(203.9)FOCAL SPOT TO SKIN DISTANCE(203.10.1)ATTENUATION EQUIVALENT of items in the X-RAY BEAM | 2022-11-18 | |
MED | IEC 60601-2-54:2009/AMD1:2015 | (201.4.10.2) Supply main for ME equipment,(201.8.5.4.101)Stator and Stator Circuit Dielectric Strength Testing,(201.8.7.3) Leakage Currents, 201.8.8.3 Dielectric Strength,201.11.102)PROTECTION AGAINST EXCESSIVE TEMPERATURES OF BEAM LIMITING DEVICES(203.4.101.2)PERCENTAGE RIPPLE IN CONSTANT POTENTIAL HIGH-VOLTAGE GENERATORS(203.6.3.2.101)REPRODUCIBILITY OF THE RADIATION OUTPUT IN RADIOGRAPHY203.6.3.2.102 A)LINEARITY OF AIR KERMA OVER LIMITED INTERVALS OF LOADING FACTORS(203.6.4.3.104.3)ACCURACY OF X-RAY TUBE VOLTAGE(203.6.4.3.104.4)ACCURACY OF X-RAY TUBE CURRENT(203.6.4.3.104.5)ACCURACY OF LOADING TIME(203.6.4.3.104.6)ACCURACY OF CURRENT TIME PRODUCT203.8.5.3)CORRESPONDENCE BETWEEN X-RAY FIELD AND IMAGE RECEPTION AREA(203.8.102)METHODS OF BEAM LIMITATION IN X-RAY EQUIPMENT(203.8.102.4)CCURACY OF MARKED AND WRITTEN INDICATIONS(203.8.102.5)INDICATION BY LIGHT FIELD-INDICATOR(203.9)(203.8.102.6)ACCURACY OF INDICATION WITH A LIGHT FIELD-INDICATOR(203.9)FOCAL SPOT TO SKIN DISTANCE(203.10.1)ATTENUATION EQUIVALENT of items in the X-RAY BEAM | 2022-11-18 | |
MED | IEC 60601-2-54:2009/AMD2:2018 | (201.4.10.2) Supply main for ME equipment,(201.8.5.4.101)Stator and Stator Circuit Dielectric Strength Testing,(201.8.7.3) Leakage Currents, 201.8.8.3 Dielectric Strength,201.11.102)PROTECTION AGAINST EXCESSIVE TEMPERATURES OF BEAM LIMITING DEVICES(203.4.101.2)PERCENTAGE RIPPLE IN CONSTANT POTENTIAL HIGH-VOLTAGE GENERATORS(203.6.3.2.101)REPRODUCIBILITY OF THE RADIATION OUTPUT IN RADIOGRAPHY203.6.3.2.102 A)LINEARITY OF AIR KERMA OVER LIMITED INTERVALS OF LOADING FACTORS(203.6.4.3.104.3)ACCURACY OF X-RAY TUBE VOLTAGE(203.6.4.3.104.4)ACCURACY OF X-RAY TUBE CURRENT(203.6.4.3.104.5)ACCURACY OF LOADING TIME(203.6.4.3.104.6)ACCURACY OF CURRENT TIME PRODUCT203.8.5.3)CORRESPONDENCE BETWEEN X-RAY FIELD AND IMAGE RECEPTION AREA(203.8.102)METHODS OF BEAM LIMITATION IN X-RAY EQUIPMENT(203.8.102.4)CCURACY OF MARKED AND WRITTEN INDICATIONS(203.8.102.5)INDICATION BY LIGHT FIELD-INDICATOR(203.9)(203.8.102.6)ACCURACY OF INDICATION WITH A LIGHT FIELD-INDICATOR(203.9)FOCAL SPOT TO SKIN DISTANCE(203.10.1)ATTENUATION EQUIVALENT of items in the X-RAY BEAM | 2022-11-18 |