Signify (China) Investment Co Ltd

Address(es)
  • 3F EAST, NO 9, LANE 888 TIANLIN RD,
    SHANGHAI 200233
    China

Website Not available
Status

MEMBER

Acceptance date 2017-11-02

Further information

Stage

Country

Name

3

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

ITAV

4.4.3.2, ANNEX T.4 STEADY FORCE TEST, 100 N4.4.3.2, ANNEX T.5 STEADY FORCE TEST, 250 N4.4.3.2, ANNEX T.3 STEADY FORCE TEST, 30 N4.4.3.3, ANNEX T.7 DROP TEST4.4.3.4, ANNEX T.6 IMPACT TEST4.4.3.5, ANNEX T.3 STEADY FORCE TEST FOR INTERNAL ENCLOSURE AND BARRIER4.4.3.8, ANNEX T.8 STRESS RELIEF TEST5.2.2.1-5.2.2.6 CLASSIFICATION OF ELECTRICAL ENERGY SOURCESB.1.5, B.2.6, 5.4.1.4, 6.3, 9.3 NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENT5.4.1.8 DETERMINATION OF WORKING VOLTAGE5.4.1.10.3 BALL PRESSURE TEST5.4.2.4 MINIMUM CLEARANCE BASED UPON ELECTRIC STRENGTH TEST5.4.4.6.2 SEPARABLE THIN SHEET MATERIAL5.4.8 HUMIDITY CONDITIONING5.4.9 ELECTRIC STRENGTH TEST5.5.2.2 CAPACITOR DISCHARGE AFTER DISCONNECTION OF A CONNECTOR5.6.6.2 RESISTANCE OF THE PROTECTIVE BONDING SYSTEM5.7.5 TOUCH CURRENT MEASUREMENT – EARTHED ACCESSIBLE CONDUCTIVE PARTS5.7.6 PROTECTIVE CONDUCTOR CURRENT8.5.3, ANNEX T.8, ANNEX V ACCESSIBILITY TO MOVING PARTS8.7 WALL, CEILING OR OTHER STRUCTUREANNEX B.2.5 INPUT TEST: SINGLE PHASEANNEX B.3 SIMULATED ABNORMAL OPERATING CONDITIONSANNEX B.4 SIMULATED SINGLE FAULT CONDITIONSANNEX F.3.10 TEST FOR THE PERMANENCE OF MARKINGSANNEX G.5.3.3 TRANSFORMER OVERLOADANNEX G.5.4.5 RUNNING OVERLOAD TEST FOR D.C. MOTORSANNEX G.5.4.6 LOCKED-ROTOR OVERLOAD TEST FOR D.C. MOTORSANNEX Q.1 LIMITED POWER SOURCEANNEX T.2 , 5.4.2.6, 5.4.3.2, G.15.2.6 STEADY FORCE TEST, 10 N6.4.8.2, ANNEX S.1 FIRE ENCLOSURE/FIRE BARRIER FLAMMABILITY TEST: STEADY STATE POWER DOES NOT EXCEED 4 000 W6.4.8.3.3, ANNEX S.2 TOP OPENINGS AND TOP OPENING PROPERTIES6.4.8.4, ANNEX S.2 FIRE ENCLOSURE/FIRE BARRIER INTEGRITY TEST
2020-11-20

ITAV

4.4.4.2, ANNEX T.4 STEADY FORCE TEST, 100 N4.4.4.2, ANNEX T.5 STEADY FORCE TEST, 250 N4.4.4.2, ANNEX T.3 STEADY FORCE TEST, 30 N4.4.4.3, ANNEX T.7 DROP TEST4.4.4.4, ANNEX T.6 IMPACT TEST4.4.4.5, ANNEX T.3 STEADY FORCE TEST FOR INTERNAL ENCLOSURE AND BARRIER4.4.4.7, ANNEX T.8 STRESS RELIEF TEST5.2, 5.7 CLASSIFICATION OF ELECTRICAL ENERGY SOURCES5.4.1.4, Annex B.2, 6.3, 9.2.5 MAXIMUM OPERATING TEMPERATURE FOR MATERIALS, COMPONENTS AND SYSTEMS5.4.1.8 DETERMINATION OF WORKING VOLTAGE5.4.1.10.3 BALL PRESSURE TEST5.4.2.4 MINIMUM CLEARANCE BASED UPON ELECTRIC STRENGTH TEST5.4.4.6.2 SEPARABLE THIN SHEET MATERIAL5.4.8 HUMIDITY CONDITIONING5.4.9 ELECTRIC STRENGTH TEST5.5.2.2 SAFEGUARDS AGAINST CAPACITOR DISCHARGE AFTER DISCONNECTION OF A CAPACITOR5.6.6.2(a) RESISTANCE OF THE PROTECTIVE BONDING SYSTEM5.7 PROSPECTIVE TOUCH VOLTAGE AND TOUCH CURRENT MEASUREMENT5.7.5 PROTECTIVE CONDUCTOR CURRENT8.5.3, ANNEX T.8, ANNEX V ACCESSIBILITY TO MOVING PARTS6.3 NORMAL OPERATING CONDITIONS TEMPERATURE TEST8.7 WALL OR CEILING MOUNTING TESTSANNEX B.2.5 INPUT TEST: SINGLE PHASEANNEX B.2.6 NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENTANNEX B.3 SIMULATED ABNORMAL OPERATING CONDITIONSANNEX B.4 SIMULATED SINGLE FAULT CONDITIONSANNEX F.3.10 TEST FOR THE PERMANENCE OF MARKINGSANNEX G.5.3.3 TRANSFORMER OVERLOADANNEX G.5.4.5 RUNNING OVERLOAD TEST FOR D.C. MOTORSANNEX G.5.4.6 LOCKED-ROTOR OVERLOAD TEST FOR D.C. MOTORSANNEX Q.1 LIMITED POWER SOURCEANNEX T.2 , 5.4.2.6, 5.4.3.2, G.15.3.6 STEADY FORCE TEST, 10 N6.4.8.2, ANNEX S.1 FIRE ENCLOSURE/FIRE BARRIER FLAMMABILITY TEST: STEADY STATE POWER DOES NOT EXCEED 4 000 W6.4.8.3.3, ANNEX S.2 TOP OPENINGS AND TOP OPENING PROPERTIES6.4.8.4, ANNEX S.2 FIRE ENCLOSURE/FIRE BARRIER INTEGRITY TEST
2020-11-20

LITE

4 General Requirements - Mechanical strength4 General Requirements - Supply connection and other external wire4 General Requirements - Thermal test (normal operation)4 General Requirements - Thermal test (abnormal operation)4 General Requirements - Mechanical strength4 General Requirements - Supply connection and other external wire4 General Requirements - Thermal test (normal operation)4 General Requirements - Thermal test (abnormal operation)7 Marking9 Earthing10 Protection against accidental contact with live parts11 Moisture resistance and insulation12 Electric strength14 Fault conditions15 Construction16 Creepage distances and clearances17 Screws, current-carrying parts and connections18.1 Ball pressure18.3 Glow wire18.4 Needle flame19 Resistance to corrosion20 No-load output voltageAnnex A "Test to establish whether a conductive partis a live part which may cause an electric shock"Annex C Particular requirements for electronic lamp controlgear with means of protection against overheatingAnnex D Requirements for carrying out the heating tests of thermally protected lamp controlgearAnnex H.12 Lamp controlgear heatingAnnex L Particular additional requirements for controlgears providing SELVAnnex O Additional requirements for built-in electronic controlgear with double or reinforced insulationAnnex O Additional requirements for built-in electronic controlgear with double or reinforced insulation7 Marking9 Earthing10 Protection against accidental contact with live parts11 Moisture resistance and insulation12 Electric strength14 Fault conditions15 Construction16 Creepage distances and clearances17 Screws, current-carrying parts and connections18.1 Ball pressure18.3 Glow wire18.4 Needle flame19 Resistance to corrosion20 No-load output voltageAnnex A "Test to establish whether a conductive partis a live part which may cause an electric shock"Annex C Particular requirements for electronic lamp controlgear with means of protection against overheatingAnnex D Requirements for carrying out the heating tests of thermally protected lamp controlgearAnnex H.12 Lamp controlgear heatingAnnex L Particular additional requirements for controlgears providing SELV
2019-07-07

LITE

7 Marking9 Earthing10 Protection against accidental contact with live parts11 Moisture resistance and insulation12 Electric strength14 Fault conditions15 Construction16 Creepage distances and clearances17 Screws, current-carrying parts and connections18.1 Ball pressure18.3 Glow wire18.4 Needle flame19 Resistance to corrosion20 No-load output voltageAnnex A "Test to establish whether a conductive partis a live part which may cause an electric shock"Annex C Particular requirements for electronic lamp controlgear with means of protection against overheatingAnnex D Requirements for carrying out the heating tests of thermally protected lamp controlgearAnnex H.12 Lamp controlgear heatingAnnex L Particular additional requirements for controlgears providing SELV
2020-11-09

LITE

7 Marking8 Protection against accidental contact with live parts10 Provisions for protective earthing11 Moisture resistance and insulation12 Electric strength14 Fault conditions15 Transformer heating16 Construction17 Creepage distances and clearances18 Screws, current-carrying parts and connections19 Ball pressure19 Glow wire19 Needle flame20 Resistance to corrosion21 Maximum working voltage (Uout) in any load conditionAnnex A "Test to establish whether a conductive partis a live part which may cause an electric shock"Annex C Particular requirements for electronic lamp controlgear with means of protection gainst overheatingAnnex D Requirements for carrying out the heating tests of thermally protected lamp controlgearAnnex H TestsAnnex I Particular additional requirements for SELV d.c. or a.c. supplied electronic controlgear for LED modulesAnnex J Particular additional safety requirements for a.c., a.c./d.c. or d.c. supplied electronic controlgear for emergency lighting
2019-07-07

LITE

7 Marking8 Protection against accidental contact with live parts10 Provisions for protective earthing11 Moisture resistance and insulation12 Electric strength14 Fault conditions15 Transformer heating16 Construction17 Creepage distances and clearances18 Screws, current-carrying parts and connections19 Ball pressure19 Glow wire19 Needle flame20 Resistance to corrosion21 Maximum working voltage (Uout) in any load conditionAnnex A "Test to establish whether a conductive partis a live part which may cause an electric shock"Annex C Particular requirements for electronic lamp controlgear with means of protection gainst overheatingAnnex D Requirements for carrying out the heating tests of thermally protected lamp controlgearAnnex H TestsAnnex I Particular additional requirements for SELV d.c. or a.c. supplied electronic controlgear for LED modulesAnnex J Particular additional safety requirements for a.c., a.c./d.c. or d.c. supplied electronic controlgear for emergency lighting
2019-07-07

LITE

6 Marking8 Earthing9 Protection against accidental contact with live parts10 Moisture resistance and insulation11 Electric strength12 Fault conditions14 Construction15 Creepage distances and clearances16 Screws, current-carrying parts and connections17 Ball pressure17 Glow wire17 Needle flame18 Resistance to corrosion
2020-11-09

LITE

7 Marking9 Provisions for protective earthing10 Protection against accidental contact with live parts11 Moisture resistance and insulation12 Electric strength13 Fault conditions15 Construction16 Creepage distances and clearances17 Screws, current-carrying parts and connections18 Ball pressure18 Glow wire18 Needle flame19 Resistance to corrosion6 Marking8 Earthing9 Protection against accidental contact with live parts10 Moisture resistance and insulation11 Electric strength12 Fault conditions14 Construction15 Creepage distances and clearances16 Screws, current-carrying parts and connections17 Ball pressure17 Glow wire17 Needle flame18 Resistance to corrosion
2019-07-07

LITE

7 Marking9 Provisions for protective earthing10 Protection against accidental contact with live parts11 Moisture resistance and insulation12 Electric strength13 Fault conditions15 Construction16 Creepage distances and clearances17 Screws, current-carrying parts and connections18 Ball pressure18 Glow wire18 Needle flame19 Resistance to corrosion
2019-06-07

LITE

7 Marking9 Provisions for protective earthing10 Protection against accidental contact with live parts11 Moisture resistance and insulation12 Electric strength13 Fault conditions15 Construction16 Creepage distances and clearances17 Screws, current-carrying parts and connections18 Ball pressure18 Glow wire18 Needle flame19 Resistance to corrosion
2019-07-07

LITE

6 Marking7.1 Starting and connecting requirements7.2 Voltage and current during operation7.3 Capacitive load requirement8 Total circuit power9 Circuit power factor10 Supply current11 Operational tests for abnormal conditions12 EnduranceAnnex A Tests
2021-06-25

LITE

6 Marking7.1 Starting and connecting requirements7.2 Voltage and current during operation7.3 Capacitive load requirement7.4 Voltage surges during switching and operation8 Total circuit power9 Circuit power factor10 Supply current12 Operational tests for abnormal conditions13 EnduranceAnnex A Tests
2019-07-07

LITE

6 Marking7.1 Starting and connecting requirements7.2 Voltage and current during operation7.3 Capacitive load requirement7.4 Voltage surges during switching and operation8 Total circuit power9 Circuit power factor10 Supply current12 Operational tests for abnormal conditions13 EnduranceAnnex A Tests
2019-07-07