Siemens AG SIMATIC Type Test Karlsruhe

Address(es)
  • Östliche Rheinbrückenstraße 50, 76187 Karlsruhe
    Germany

Website Not available
Status

MEMBER

Acceptance date 2019-07-25

Further information

Stage

Country

Name

2

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

MEAS

4.4.1 COMPONENT ABNORMAL TEST 4.4.2.2 PROTECTIVE IMPEDANCE ABNORMAL TEST 4.4.2.3 PROTECTIVE CONDUCTOR ABNORMAL TEST 4.4.2.4 SHORT TERM / INTERMITTENT DUTY ABNORMAL 4.4.2.7.2 MAINS TRANSFORMER SHORT CIRCUIT ABNORMAL TEST 4.4.2.7.3 MAINS TRANSFORMER OVERLOAD ABNORMAL TEST 4.4.2.8 OUTPUT ABNORMAL TEST 4.4.2.10 COOLING ABNORMAL 4.4.2.14 SUPPLY VOLTAGE SELECTOR 5.1.3 INPUT POWER/CURRENT MEASUREMENT 5.3 DURABILITY OF MARKING TEST 6.2.2 APPLIED FORCE 6.2.3 OPENINGS ABOVE PARTS THAT ARE HAZARDOUS LIVE 6.2.4 OPENINGS FOR PRE‐SET CONTROLS 6.3.1 LIMIT VALUES FOR ACCESSIBLE PARTS (NORMAL CONDITIONS) 6.3.2 LIMIT VALUES FOR ACCESSIBLE PARTS (SINGLE FAULT CONDITIONS) 6.8 DIELECTRIC VOLTAGE WITHSTAND 6.8.2 HUMIDITY PRECONDITIONING 7.6 WALL MOUNTING 8.2.2 IMPACT 9.4 LIMITED ENERGY CIRCUIT DETERMINATION TEST 10.1‐10.4 NORMAL TEMPERATURE TEST
2019-10-30

MEAS

4.4.1 COMPONENT ABNORMAL TEST 4.4.2.2 PROTECTIVE IMPEDANCE ABNORMAL TEST 4.4.2.3 PROTECTIVE CONDUCTOR ABNORMAL TEST 4.4.2.4 SHORT TERM / INTERMITTENT DUTY ABNORMAL 4.4.2.7.2 MAINS TRANSFORMER SHORT CIRCUIT ABNORMAL TEST 4.4.2.7.3 MAINS TRANSFORMER OVERLOAD ABNORMAL TEST 4.4.2.8 OUTPUT ABNORMAL TEST 4.4.2.10 COOLING ABNORMAL 4.4.2.14 SUPPLY VOLTAGE SELECTOR 5.1.3 INPUT POWER/CURRENT MEASUREMENT 5.3 DURABILITY OF MARKING TEST 6.2.2 APPLIED FORCE 6.2.3 OPENINGS ABOVE PARTS THAT ARE HAZARDOUS LIVE 6.2.4 OPENINGS FOR PRE‐SET CONTROLS 6.3.1 LIMIT VALUES FOR ACCESSIBLE PARTS (NORMAL CONDITIONS) 6.3.2 LIMIT VALUES FOR ACCESSIBLE PARTS (SINGLE FAULT CONDITIONS) 6.8 DIELECTRIC VOLTAGE WITHSTAND 6.8.2 HUMIDITY PRECONDITIONING 7.6 WALL MOUNTING 8.2.2 IMPACT 9.4 LIMITED ENERGY CIRCUIT DETERMINATION TEST 10.1‐10.4 NORMAL TEMPERATURE TEST
2019-10-30

MEAS

4.4.1.101.1 OVERLOAD TEST 4.4.1.101.2 ENDURANCE TEST
2019-10-30