Shenzhen First Union Technology Co., LTD.
Shenzhen First Union Technology Co., LTD.
Address(es) |
|
Website | https://www.chinafirstunion.com/ |
Status | MEMBER |
Acceptance date | 2021-11-01 |
Further information
Stage | Country | Name |
---|---|---|
1 | Germany |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
BATT | IEC 62133-2:2017 | Exceptions: Cl. 7.3.9: Design evaluation – Forced internal short circuit (cells) | 2021-11-01 | |
HOUS | IEC 60335-1:2020 | Exceptions: Cl. 8.4: Live part judgment for accessible partCl. 13.2: Leakage current at operating temperatureCl. 14: Transient overvoltageCl. 15.1: IP testCl. 15.2: Spillage testCl. 16.2: Leakage currentCl. 19.11.4: EMS testCl. 20.1: Stability testCl. 21.2: Solid insulation strength test (scratch test)Cl. 22.3: Torque measurement for pin supported applianceCl. 22.5: Plug discharge testCl. 22.7: Pressure testCl. 23.3: Internal wire flexing testCl. 24.1.1: Capacitor TestCl. 24.1.2: Safety isolating transformer TestCl. 24.1.4 – Cl. 24.1.9: Component testCl. 25.14: Supply cord flexing testCl. 26.3 Torque testCl. 27.4: Coating measurementCl. 27.5: Earthing resistanceCl. 28.1: Torque testCl. 30.2: Glow-wire test for soft or foamy materialAnnex B_B20.1, B20.2: Ventingl testAnnex F: Capacitor testAnnex G: Safety isolating transformer testAnnex H: Switch TestAnnex J: Coated Printed Circuit Boards TestAnnex R: Software EvaluationAnnex T: UV-C radiation effect on non-metallic materialsAnnex U: Evaluation for remote communication through public networks | 2024-01-15 | |
HOUS | IEC 60335-1:2010 | Exceptions:Cl. 8.4: Live part judgment for accessible partCl. 13.2: Leakage current at operating temperatureCl. 14: Transient overvoltageCl. 15.1: IP testCl. 15.2: Spillage testCl. 19.11.4: EMS testCl. 20.1: Stability testCl. 21.2: Solid insulation strength test (scratch test)Cl. 22.3: Torque measurement for pin supported applianceCl. 22.5: Plug discharge testCl. 22.7: Pressure testCl. 22.16: Automatic cord reels testCl. 22.32: Oxygen bomb testCl. 22.48: Backsiphonage testCl. 23.3: Internal wire flexing testCl. 24.1.1: Capacitor TestCl. 24.1.2: Safety isolating transformer TestCl. 24.1.4 – Cl. 24.1.9: Component testCl. 25.14: Supply cord flexing testCl. 26.3 Torque testCl. 27.4: Coating measurementCl. 27.5: Earthing resistanceCl. 28.1: Torque testCl. 30.2: Glow-wire test for soft or foamy materialAnnex B_21.B.101: Free fall testAnnex F: Capacitor testAnnex G: Safety isolating transformer testAnnex H: Switch TestAnnex J: Coated Printed Circuit Boards TestAnnex R: Software EvaluationAnnex T: UV-C radiation effect on non-metallic material | 2021-11-01 | |
HOUS | IEC 60335-1:2010/AMD1:2013 | Exceptions:Cl. 8.4: Live part judgment for accessible partCl. 13.2: Leakage current at operating temperatureCl. 14: Transient overvoltageCl. 15.1: IP testCl. 15.2: Spillage testCl. 19.11.4: EMS testCl. 20.1: Stability testCl. 21.2: Solid insulation strength test (scratch test)Cl. 22.3: Torque measurement for pin supported applianceCl. 22.5: Plug discharge testCl. 22.7: Pressure testCl. 22.16: Automatic cord reels testCl. 22.32: Oxygen bomb testCl. 22.48: Backsiphonage testCl. 23.3: Internal wire flexing testCl. 24.1.1: Capacitor TestCl. 24.1.2: Safety isolating transformer TestCl. 24.1.4 – Cl. 24.1.9: Component testCl. 25.14: Supply cord flexing testCl. 26.3 Torque testCl. 27.4: Coating measurementCl. 27.5: Earthing resistanceCl. 28.1: Torque testCl. 30.2: Glow-wire test for soft or foamy materialAnnex B_21.B.101: Free fall testAnnex F: Capacitor testAnnex G: Safety isolating transformer testAnnex H: Switch TestAnnex J: Coated Printed Circuit Boards TestAnnex R: Software EvaluationAnnex T: UV-C radiation effect on non-metallic material | 2021-11-01 | |
HOUS | IEC 60335-1:2010/AMD2:2016 | Exceptions:Cl. 8.4: Live part judgment for accessible partCl. 13.2: Leakage current at operating temperatureCl. 14: Transient overvoltageCl. 15.1: IP testCl. 15.2: Spillage testCl. 19.11.4: EMS testCl. 20.1: Stability testCl. 21.2: Solid insulation strength test (scratch test)Cl. 22.3: Torque measurement for pin supported applianceCl. 22.5: Plug discharge testCl. 22.7: Pressure testCl. 22.16: Automatic cord reels testCl. 22.32: Oxygen bomb testCl. 22.48: Backsiphonage testCl. 23.3: Internal wire flexing testCl. 24.1.1: Capacitor TestCl. 24.1.2: Safety isolating transformer TestCl. 24.1.4 – Cl. 24.1.9: Component testCl. 25.14: Supply cord flexing testCl. 26.3 Torque testCl. 27.4: Coating measurementCl. 27.5: Earthing resistanceCl. 28.1: Torque testCl. 30.2: Glow-wire test for soft or foamy materialAnnex B_21.B.101: Free fall testAnnex F: Capacitor testAnnex G: Safety isolating transformer testAnnex H: Switch TestAnnex J: Coated Printed Circuit Boards TestAnnex R: Software EvaluationAnnex T: UV-C radiation effect on non-metallic material | 2021-11-01 |