Shenzhen First Union Technology Co., LTD.

Address(es)
  • 1/F, 3/F, Tangwei Sci-Tech Park Building C, Fuyong Street, Bao’an District,
    Shenzhen
    GuangDong
    China

  • 5/F, Building L, No. 17 Wan'an Road, Ma'anshan Community, Shajing Street, Bao'an District
    Shenzhen
    Guangdong
    China

Website https://www.chinafirstunion.com/
Status

MEMBER

Acceptance date 2021-11-01

Further information

Stage

Country

Name

1

Germany

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

BATT

Exceptions: Cl. 7.3.9: Design evaluation – Forced internal short circuit (cells)
2021-11-01

HOUS

Exceptions: Cl. 8.4: Live part judgment for accessible partCl. 13.2: Leakage current at operating temperatureCl. 14: Transient overvoltageCl. 15.1: IP testCl. 15.2: Spillage testCl. 16.2: Leakage currentCl. 19.11.4: EMS testCl. 20.1: Stability testCl. 21.2: Solid insulation strength test (scratch test)Cl. 22.3: Torque measurement for pin supported applianceCl. 22.5: Plug discharge testCl. 22.7: Pressure testCl. 23.3: Internal wire flexing testCl. 24.1.1: Capacitor TestCl. 24.1.2: Safety isolating transformer TestCl. 24.1.4 – Cl. 24.1.9: Component testCl. 25.14: Supply cord flexing testCl. 26.3 Torque testCl. 27.4: Coating measurementCl. 27.5: Earthing resistanceCl. 28.1: Torque testCl. 30.2: Glow-wire test for soft or foamy materialAnnex B_B20.1, B20.2: Ventingl testAnnex F: Capacitor testAnnex G: Safety isolating transformer testAnnex H: Switch TestAnnex J: Coated Printed Circuit Boards TestAnnex R: Software EvaluationAnnex T: UV-C radiation effect on non-metallic materialsAnnex U: Evaluation for remote communication through public networks
2024-01-15

HOUS

Exceptions:Cl. 8.4: Live part judgment for accessible partCl. 13.2: Leakage current at operating temperatureCl. 14: Transient overvoltageCl. 15.1: IP testCl. 15.2: Spillage testCl. 19.11.4: EMS testCl. 20.1: Stability testCl. 21.2: Solid insulation strength test (scratch test)Cl. 22.3: Torque measurement for pin supported applianceCl. 22.5: Plug discharge testCl. 22.7: Pressure testCl. 22.16: Automatic cord reels testCl. 22.32: Oxygen bomb testCl. 22.48: Backsiphonage testCl. 23.3: Internal wire flexing testCl. 24.1.1: Capacitor TestCl. 24.1.2: Safety isolating transformer TestCl. 24.1.4 – Cl. 24.1.9: Component testCl. 25.14: Supply cord flexing testCl. 26.3 Torque testCl. 27.4: Coating measurementCl. 27.5: Earthing resistanceCl. 28.1: Torque testCl. 30.2: Glow-wire test for soft or foamy materialAnnex B_21.B.101: Free fall testAnnex F: Capacitor testAnnex G: Safety isolating transformer testAnnex H: Switch TestAnnex J: Coated Printed Circuit Boards TestAnnex R: Software EvaluationAnnex T: UV-C radiation effect on non-metallic material
2021-11-01

HOUS

Exceptions:Cl. 8.4: Live part judgment for accessible partCl. 13.2: Leakage current at operating temperatureCl. 14: Transient overvoltageCl. 15.1: IP testCl. 15.2: Spillage testCl. 19.11.4: EMS testCl. 20.1: Stability testCl. 21.2: Solid insulation strength test (scratch test)Cl. 22.3: Torque measurement for pin supported applianceCl. 22.5: Plug discharge testCl. 22.7: Pressure testCl. 22.16: Automatic cord reels testCl. 22.32: Oxygen bomb testCl. 22.48: Backsiphonage testCl. 23.3: Internal wire flexing testCl. 24.1.1: Capacitor TestCl. 24.1.2: Safety isolating transformer TestCl. 24.1.4 – Cl. 24.1.9: Component testCl. 25.14: Supply cord flexing testCl. 26.3 Torque testCl. 27.4: Coating measurementCl. 27.5: Earthing resistanceCl. 28.1: Torque testCl. 30.2: Glow-wire test for soft or foamy materialAnnex B_21.B.101: Free fall testAnnex F: Capacitor testAnnex G: Safety isolating transformer testAnnex H: Switch TestAnnex J: Coated Printed Circuit Boards TestAnnex R: Software EvaluationAnnex T: UV-C radiation effect on non-metallic material
2021-11-01

HOUS

Exceptions:Cl. 8.4: Live part judgment for accessible partCl. 13.2: Leakage current at operating temperatureCl. 14: Transient overvoltageCl. 15.1: IP testCl. 15.2: Spillage testCl. 19.11.4: EMS testCl. 20.1: Stability testCl. 21.2: Solid insulation strength test (scratch test)Cl. 22.3: Torque measurement for pin supported applianceCl. 22.5: Plug discharge testCl. 22.7: Pressure testCl. 22.16: Automatic cord reels testCl. 22.32: Oxygen bomb testCl. 22.48: Backsiphonage testCl. 23.3: Internal wire flexing testCl. 24.1.1: Capacitor TestCl. 24.1.2: Safety isolating transformer TestCl. 24.1.4 – Cl. 24.1.9: Component testCl. 25.14: Supply cord flexing testCl. 26.3 Torque testCl. 27.4: Coating measurementCl. 27.5: Earthing resistanceCl. 28.1: Torque testCl. 30.2: Glow-wire test for soft or foamy materialAnnex B_21.B.101: Free fall testAnnex F: Capacitor testAnnex G: Safety isolating transformer testAnnex H: Switch TestAnnex J: Coated Printed Circuit Boards TestAnnex R: Software EvaluationAnnex T: UV-C radiation effect on non-metallic material
2021-11-01