SCHNEIDER TOSHIBA INVERTER EUROPE S A S
SCHNEIDER TOSHIBA INVERTER EUROPE S A S
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2015-02-24 |
Further information
Stage | Country | Name |
---|---|---|
3 | Denmark |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
INST | IEC 61800-5-1:2007 | 5.2.2.1 MECHANICAL TESTS - CLEARANCE AND CREEPAGE DISTANCE5.2.2.3 MECHANICAL TESTS - NON-ACCESSIBILITY5.2.2.4 MECHANICAL TESTS - ENCLOSURE INTEGRITY5.2.2.5.2 MECHANICAL TESTS - DEFORMATION - DEFLECTION 5.2.2.5.3 MECHANICAL TESTS - DEFORMATION - IMPACT5.2.3.1 ELECTRICAL TESTS - IMPULSE VOLTAGE5.2.3.2 ELECTRICAL TESTS - AC OR DC VOLTAGE5.2.3.4 ELECTRICAL TESTS - PROTECTIVE IMPEDANCE5.2.3.5 ELECTRICAL TESTS - TOUCH CURRENT MEASUREMENT5.2.3.6.4 ELECTRICAL TESTS - SHORT-CIRCUIT TEST AND BREAKDOWN OF COMPONENTS TEST - BREAKDOWN OF COMPONENTS5.2.3.7 ELECTRICAL TESTS - CAPACITOR DISCHARGE5.2.3.8 ELECTRICAL TESTS - TEMPERATURE RISE5.2.3.9 ELECTRICAL TESTS - PROTECTIVE BONDING5.2.4.4 ABNORMAL OPERATION TESTS - LOSS OF PHASE5.2.4.5.2 ABNORMAL OPERATION TESTS - COOLING FAILURE TESTS - INOPERATIVE BLOWER5.2.6.3.1 ENVIRONMENTAL TESTS - CLIMATIC TESTS - DRY HEAT5.2.6.3.2 ENVIRONMENTAL TESTS - CLIMATIC TESTS - DAMP HEAT | 2020-02-27 | |
INST | IEC 61800-5-1:2007/AMD1:2016 | 5.2.2.1 MECHANICAL TESTS - CLEARANCE AND CREEPAGE DISTANCE5.2.2.3 MECHANICAL TESTS - NON-ACCESSIBILITY5.2.2.4 MECHANICAL TESTS - ENCLOSURE INTEGRITY5.2.2.5.2 MECHANICAL TESTS - DEFORMATION - DEFLECTION 5.2.2.5.3 MECHANICAL TESTS - DEFORMATION - IMPACT5.2.3.1 ELECTRICAL TESTS - IMPULSE VOLTAGE5.2.3.2 ELECTRICAL TESTS - AC OR DC VOLTAGE5.2.3.4 ELECTRICAL TESTS - PROTECTIVE IMPEDANCE5.2.3.5 ELECTRICAL TESTS - TOUCH CURRENT MEASUREMENT5.2.3.6.4 ELECTRICAL TESTS - SHORT-CIRCUIT TEST AND BREAKDOWN OF COMPONENTS TEST - BREAKDOWN OF COMPONENTS5.2.3.7 ELECTRICAL TESTS - CAPACITOR DISCHARGE5.2.3.8 ELECTRICAL TESTS - TEMPERATURE RISE5.2.3.9 ELECTRICAL TESTS - PROTECTIVE BONDING5.2.4.4 ABNORMAL OPERATION TESTS - LOSS OF PHASE5.2.4.5.2 ABNORMAL OPERATION TESTS - COOLING FAILURE TESTS - INOPERATIVE BLOWER5.2.6.3.1 ENVIRONMENTAL TESTS - CLIMATIC TESTS - DRY HEAT5.2.6.3.2 ENVIRONMENTAL TESTS - CLIMATIC TESTS - DAMP HEAT5.2.8 ELECTRONIC MOTOR OVERLOAD PROTECTION (TYPE TEST)5.2.8.1 ELECTRONIC MOTOR OVERLOAD PROTECTION (TYPE TEST) - GENERAL EQUIREMENTS5.2.8.2 ELECTRONIC MOTOR OVERLOAD PROTECTION (TYPE TEST) - TEST SET-UP5.2.8.3 ELECTRONIC MOTOR OVERLOAD PROTECTION (TYPE TEST) - PASS CRITERIA5.2.8.4 ELECTRONIC MOTOR OVERLOAD PROTECTION (TYPE TEST) - CDM/BDM ELECTRONIC MOTOR OVERLOAD PROTECTION TEST (TYPE TEST)5.2.8.5 ELECTRONIC MOTOR OVERLOAD PROTECTION (TYPE TEST) - CDM/BDM ELECTRONIC MOTOR THERMAL MEMORY RETENTION SHUTDOWN TEST (TYPE TEST)5.2.8.6 ELECTRONIC MOTOR OVERLOAD PROTECTION (TYPE TEST) - CDM/BDM ELECTRONIC MOTOR THERMAL MEMORY RETENTION LOSS OF POWER TEST (TYPE TEST)5.2.8.7 ELECTRONIC MOTOR OVERLOAD PROTECTION (TYPE TEST) - CDM/BDM ELECTRONIC MOTOR THERMAL SPEED SENSITIVITY TEST (TYPE TEST)5.2.1 Visual inspections5.2.3.3 ELECTRICAL TESTS – PARTIAL DISCHARGE | 2020-02-27 | |
POW | IEC 60947-1:2020 | 9.3.3.3 Temperature-rise9.3.3.4 Dielectric properties9.2.5 Mechanical and electrical properties of terminals9.2.5.1 General conditions for tests9.2.5.2 Tests of mechanical strength of terminals9.2.5.3 Testing for damage to and accidental loosening of conductors (flexion test)9.2.5.4.1 Pull-out test - Round copper conductorsAnnex C.11 General requirements for testsAnnex C.12 "Tests for protection against access to hazardous parts indicated by thefirst characteristic numeral"Annex C.13 "Tests for protection against ingress of solid foreign objects indicated bythe first characteristic numeral"Annex C.15 "Tests for protection against access to hazardous parts indicated byadditional letter" | 2022-03-16 | |
POW | IEC 60947-1:2007 | 8.2.4.2 Tests of mechanical strength of terminals8.2.4.3 Testing for damage to and accidental loosening of conductors (flexion test)8.2.4.4.1 Pull out - Round copper conductors8.3.3.3 Temperature-rise8.3.3.4 Dielectric propertiesAnnex C.11 General requirements for testsAnnex C.12 Tests for protection against access to hazardous parts indicated by the first characteristic numeralAnnex C.13 Tests for protection against ingress of solid foreign objects indicated by the first characteristic numeralAnnex C.15 Tests for protection against access to hazardous parts indicated by additional letter | 2024-01-30 | |
POW | IEC 60947-4-2:2020 | 8.2.1.5 Limits of operation of current sensing relays and releases9.2.4 Limited energy source test9.2.5 Breakdown of components9.3.3.3 Temperature-rise9.3.3.4 Dielectric properties9.1.2 g) Mechanical Properties of Terminals8.1.2 Degrees of protection of enclosed equipment8.2.1.5.1.1 LIMITS OF OPERATION OF TIME-DELAY OVERLOAD RELAYS WHEN ALL POLES ARE ENERGIZED8.2.1.5.1.2 THERMAL MEMORY TEST VERIFICATION9.3.3.6.3 Overload capability test 9.3.3.6.4 Blocking and commutating capability test | 2023-02-09 | |
POW | IEC 60947-4-2:2011 | 8.2.1.5 Limits of operation of current sensing relays and releases9.3.3.3 Temperature-rise9.3.3.4 Dielectric properties | 2024-01-30 |