Schneider Electric Pvt Ltd.

Address(es)
  • Beary's Global Research Triangle (BGRT), Sy. No 63/3B,Gorvigere Village, Bidarahalli
    Hobli,Whitefield Ashram Road,Bangalore Karnataka 560067,
    IN-560067 Bangalore
    India

Website Not available
Status

MEMBER

Acceptance date 2019-08-06

Further information

Stage

Country

Name

2

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

MEAS

4.4. Single Fault Condition Tests4.4.1 Component Abnormal4.4.2.2 Protective Impedance Abnormal Test 4.4.2.3 Protective Conductor Abnormal Test4.4.2.7.2 Mains Transformer Short Circuit Test4.4.2.7.3 Mains Transformer Overload Test4.4.2.8 Output Abnormal Test4.4.2.9 Multi-Supply Abnormal Test 4.4.2.10 Cooling Abnormal Test4.4.2.12 Insulation Between Circuits And Parts Abnormal Test5.1.3 Mains Supply5.3 Durability Of Markings Test 6.2 Determination Of Accessible Parts6.3 Limit Values For Accessible Parts6.5.2.3 J Tightening Torque Test 6.5.2.4 and 6.5.2.5 Grounding Continuity Test6.5.2.6 Transformer Protective Bonding Screen Test6.7 , ANNEX K Insulation Requirements6.8 Dielectric Voltage Withstand Test6.8.2 Humidity Conditioning Test7.6 Wall Mounting Test8.2.1 Rigidity Test8.2.2 Impact Test8.3.1 Drop Test Other Than Hand-Held Equipment And Direct Plug-In Equipment8.3.2 Drop Test Hand-Held Equipment And Direct Plug-In Equipment9.4 Limited Energy Circuit Determination Test10.1 to 10.4 Temperature Test ( For IEC61010-1)10.1to 10.4 .1 -Sub clause 10.4.1.100,10.4.1.101, 10.4.1.102, 10.4.1.103 Tempearture Test ( For IEC61010-2-201)10.5.1 Integrity Of Clearances And Creepages Test 10.5.2 Resistance To Heat Of Nonmetallic Enclosure Test10.5.3 Ball Pressure Test11.6 Specially protected Equipment (IEC60529, IP Test)
2019-08-06

MEAS

4.4. Single Fault Condition Tests4.4.1 Component Abnormal4.4.2.2 Protective Impedance Abnormal Test 4.4.2.3 Protective Conductor Abnormal Test4.4.2.7.2 Mains Transformer Short Circuit Test4.4.2.7.3 Mains Transformer Overload Test4.4.2.8 Output Abnormal Test4.4.2.9 Multi-Supply Abnormal Test 4.4.2.10 Cooling Abnormal Test4.4.2.12 Insulation Between Circuits And Parts Abnormal Test5.1.3 Mains Supply5.3 Durability Of Markings Test 6.2 Determination Of Accessible Parts6.3 Limit Values For Accessible Parts6.5.2.3 J Tightening Torque Test 6.5.2.4 and 6.5.2.5 Grounding Continuity Test6.5.2.6 Transformer Protective Bonding Screen Test6.7 , ANNEX K Insulation Requirements6.8 Dielectric Voltage Withstand Test6.8.2 Humidity Conditioning Test7.6 Wall Mounting Test8.2.1 Rigidity Test8.2.2 Impact Test8.3.1 Drop Test Other Than Hand-Held Equipment And Direct Plug-In Equipment8.3.2 Drop Test Hand-Held Equipment And Direct Plug-In Equipment9.4 Limited Energy Circuit Determination Test10.1 to 10.4 Temperature Test ( For IEC61010-1)10.1to 10.4 .1 -Sub clause 10.4.1.100,10.4.1.101, 10.4.1.102, 10.4.1.103 Tempearture Test ( For IEC61010-2-201)10.5.1 Integrity Of Clearances And Creepages Test 10.5.2 Resistance To Heat Of Nonmetallic Enclosure Test10.5.3 Ball Pressure Test11.6 Specially protected Equipment (IEC60529, IP Test)
2020-02-13

MEAS

101.2 Current Measuring Circuits Test6.9.101 Over Range Indication Test
2020-02-13

MEAS

4.4. Single Fault Condition Tests4.4.1 Component Abnormal4.4.2.2 Protective Impedance Abnormal Test 4.4.2.3 Protective Conductor Abnormal Test4.4.2.7.2 Mains Transformer Short Circuit Test4.4.2.7.3 Mains Transformer Overload Test4.4.2.8 Output Abnormal Test4.4.2.9 Multi-Supply Abnormal Test 4.4.2.10 Cooling Abnormal Test4.4.2.12 Insulation Between Circuits And Parts Abnormal Test5.1.3 Mains Supply5.3 Durability Of Markings Test 6.2 Determination Of Accessible Parts6.3 Limit Values For Accessible Parts6.5.2.3 J Tightening Torque Test 6.5.2.4 and 6.5.2.5 Grounding Continuity Test6.5.2.6 Transformer Protective Bonding Screen Test6.7 , ANNEX K Insulation Requirements6.8 Dielectric Voltage Withstand Test6.8.2 Humidity Conditioning Test7.6 Wall Mounting Test8.2.1 Rigidity Test8.2.2 Impact Test8.3.1 Drop Test Other Than Hand-Held Equipment And Direct Plug-In Equipment8.3.2 Drop Test Hand-Held Equipment And Direct Plug-In Equipment9.4 Limited Energy Circuit Determination Test10.1 to 10.4 Temperature Test ( For IEC61010-1)10.1to 10.4 .1 -Sub clause 10.4.1.100,10.4.1.101, 10.4.1.102, 10.4.1.103 Tempearture Test ( For IEC61010-2-201)10.5.1 Integrity Of Clearances And Creepages Test 10.5.2 Resistance To Heat Of Nonmetallic Enclosure Test10.5.3 Ball Pressure Test11.6 Specially protected Equipment (IEC60529, IP Test)
2020-02-13