Schneider Electric IT Denmark ApS

Address(es)
  • Silicon Allé 1
    Kolding
    DK-6000
    Denmark

Website Not available
Status

MEMBER

Acceptance date 2015-10-21

Further information

Stage

Country

Name

2

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

MEAS

4.4.1, COMPONENT ABNORMAL4.4.2.3, PROTECTIVE CONDUCTOR ABNORMAL TEST4.4.2.8, OUTPUT ABNORMAL TEST6.10.3, PLUGS AND CONNECTORS5.1.3, MAINS SUPPLY6.2, DETERMINATION OF ACCESSIBLE PARTS6.3, LIMIT VALUES FOR ACCESSIBLE PARTS6.5.2.3J, TIGHTENING TORQUE TEST6.5.2.4, 6.5.2.5, GROUNDING CONTINUITY TEST6.7, ANNEX K, INSULATION REQUIREMENTS6.8, DIELECTRIC VOLTAGE WITHSTAND TEST6.8.2, HUMIDITY CONDITIONING TEST7.2, SHARP EDGES7.6, WALL MOUNTING TEST8.2.1, RIGIDITY TEST8.2.2, IMPACT TEST9.4, LIMITED ENERGY CIRCUIT DETERMINATION TEST10.1-10.4, TEMPERATURE TEST10.5.1, INTEGRITY OF CLEARANCES AND CREEPAGES TEST10.5.2, RESISTANCE TO HEAT OF NONMETALLIC ENCLOSURE TEST
2023-08-08

MEAS

4.4.1, COMPONENT ABNORMAL4.4.2.3, PROTECTIVE CONDUCTOR ABNORMAL TEST4.4.2.8, OUTPUT ABNORMAL TEST6.10.3, PLUGS AND CONNECTORS5.1.3, MAINS SUPPLY6.2, DETERMINATION OF ACCESSIBLE PARTS6.3, LIMIT VALUES FOR ACCESSIBLE PARTS6.5.2.3J, TIGHTENING TORQUE TEST6.5.2.4, 6.5.2.5, GROUNDING CONTINUITY TEST6.7, ANNEX K, INSULATION REQUIREMENTS6.8, DIELECTRIC VOLTAGE WITHSTAND TEST6.8.2, HUMIDITY CONDITIONING TEST7.2, SHARP EDGES7.6, WALL MOUNTING TEST8.2.1, RIGIDITY TEST8.2.2, IMPACT TEST9.4, LIMITED ENERGY CIRCUIT DETERMINATION TEST10.1-10.4, TEMPERATURE TEST10.5.1, INTEGRITY OF CLEARANCES AND CREEPAGES TEST10.5.2, RESISTANCE TO HEAT OF NONMETALLIC ENCLOSURE TEST
2023-08-08

MEAS

10.4.1.100–10.4.1.103, TEMPERATURE TEST
2023-08-08

OFF

5.2.3.2 RD, Impulse voltage test5.2.3.4/RD, AC or DC voltage test (dielectric strength test)5.2.3.6/RD, Protective impedance test5.2.3.7/AD, Touch current measurement test5.2.3.8/AD, Capacitor discharge test5.2.3.9 /RD, Limited power source, test including energy hazards test5.2.3.10/RD, Temperature rise test5.2.3.101, Backfeed protection test5.2.3.11 / 5.2.4.3/RD, Protectiveequipotential bonding5.2.3.102, Input current5.2.3.104, Transformer protectionAnnex CC, Charging voltages5.2.4.4/RD, Output short-circuit test5.2.3.105, Unsynchronised load transfer test5.2.4.5/RD, Output overload test5.2.4.6/RD, Breakdown of components test5.2.4.8/RD, Loss of phase test5.2.4.9/RD, Cooling failure tests5.2.4.9.2/RD, Inoperative blower test5.2.4.9.3/RD, Clogged filter test5.2.6.3.1/RD, Dry heat test5.2.6.3.2/RD, Damp heat test5.2.2.1/RD, Clearance and creepage distances test5.2.2.3/RD, Ingress protection test (IP rating)5.2.2.4.2.3/RD, Steady force test, 250 N5.2.2.4.3/RD, Impact test5.2.2.5/RD, Stability test5.2.2.4.5/RD, Stress relief test5.2.2.4.2.2/RD, Steady force test, 30 N5.2.2.4/RD, Enclosure integrity test5.2.2.4.2/RD, Deflection test
2023-03-21

OFF

8.1, 5.1/RD, Annex D/ RD, touch current measurement4.6, 1.6.2/RD, Electrical Data (In normal conditions)7.7, 4.5.1/RD, 1.4.12/RD, 1.4.13/RD, Heating Test8.2, 5.2/RD, Electric Strength5.1.1, 2.1.1/RD, 2.8.2/RD, Access to energized parts test5.1.1, 5.6.2.7, 2.1.1.5/RD, 2.1.2/RD, 1.2.8.10/RD, Stored Energy5.2.1, 2.2.2/RD, 2.2.3/RD, 2.2.4/RD, Evaluation Of Voltage Limiting Components In SELV Circuits5.2.3, 2.4.1/RD, 2.4.2/RD, Limited Current Circuit measurements5.2.5, 2.5/RD, Limited Power Sources5.3.1, 2.6.3.4/RD, Resistance of earthing conductors and their terminations5.7, 2.10.2/RD, Working Voltage Measurement7.2, RD 4.1, Stability test7.3, 4.2.1/RD, 4.2.2/RD, 4.2.3/RD, 4.2.4/RD, Steady force test7.3, 4.2.1/RD, 4.2.5/RD, Impact test7.4.1, RD 4.3.2, Knob Pull/Handle Loading test7.6.8, 8.3.1, 8.3.2, Battery overcharge/Discharge test8.3.1, 5.3.3/ RD, Transformer abnormal operation test.8.3.2, 8.3.1, 5.3.1/ RD, 5.3.4/ RD, Component short and open circuit abnormal test8.3.2, Output overload abnormal test8.3.2, DC in reverse polarity test8.3.2, Forced ventilation abnormal testAnnex M4, Overcharge abnormal test8.3.2, Output Short circuit abnormal test5.1.4, Annex I, Back feed protection test
2019-08-19

OFF

8.1, 5.1/RD, Annex D/ RD, touch current measurement4.6, 1.6.2/RD, Electrical Data (In normal conditions)7.7, 4.5.1/RD, 1.4.12/RD, 1.4.13/RD, Heating Test8.2, 5.2/RD, Electric Strength5.1.1, 2.1.1/RD, 2.8.2/RD, Access to energized parts test5.1.1, 5.6.2.7, 2.1.1.5/RD, 2.1.2/RD, 1.2.8.10/RD, Stored Energy5.2.1, 2.2.2/RD, 2.2.3/RD, 2.2.4/RD, Evaluation Of Voltage Limiting Components In SELV Circuits5.2.3, 2.4.1/RD, 2.4.2/RD, Limited Current Circuit measurements5.2.5, 2.5/RD, Limited Power Sources5.3.1, 2.6.3.4/RD, Resistance of earthing conductors and their terminations5.7, 2.10.2/RD, Working Voltage Measurement7.2, RD 4.1, Stability test7.3, 4.2.1/RD, 4.2.2/RD, 4.2.3/RD, 4.2.4/RD, Steady force test7.3, 4.2.1/RD, 4.2.5/RD, Impact test7.4.1, RD 4.3.2, Knob Pull/Handle Loading test7.6.8, 8.3.1, 8.3.2, Battery overcharge/Discharge test8.3.1, 5.3.3/ RD, Transformer abnormal operation test.8.3.2, 8.3.1, 5.3.1/ RD, 5.3.4/ RD, Component short and open circuit abnormal test8.3.2, Output overload abnormal test8.3.2, DC in reverse polarity test8.3.2, Forced ventilation abnormal testAnnex M4, Overcharge abnormal test8.3.2, Output Short circuit abnormal test5.1.4, Annex I, Back feed protection test
2019-08-19