Schneider Electric France DBA Automation

Address(es)
  • 8EME RUE, ZI
    FR-06516 CARROS
    France

Website Not available
Status

MEMBER

Acceptance date 2015-05-27

Further information

Stage

Country

Name

3

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

MEAS

10.1-10.4 TEMPERATURE TEST10.5.2 RESISTANCE TO HEAT OF NONMETALLIC ENCLOSURES4.4 SINGLE FAULT CONDITION4.4.2.7.2 MAINS TRANSFORMER SHORT CIRCUIT4.4.2.7.3 MAINS TRANSFORMER OVERLOAD4.4.2.8 OUTPUT ABNORMAL5.1.3 INPUT POWER/CURRENT MEASUREMENT5.3 DURABILITY OF MARKINGS6.2 DETERMINATION OF ACCESSIBLE PARTS6.3 PERMISSIBLE LIMITS6.5.2.3.J TIGHTENING TORQUE6.5.2.4 AND 6.5.2.5 GROUNDING CONTINUITY TEST6.7, ANNEX K INSULATION REQUIREMENTS6.8 DIELECTRIC STRENGTH6.8.2 HUMIDITY CONDITIONING 8.2.1 STATIC TEST8.2.2 IMPACT4.4.1 COMPONENT ABNORMAL4.4.2.3 PROTECTIVE CONDUCTOR ABNORMAL9.4 LIMITED ENERGY CIRCUIT DETERMINATION
2019-07-03

MEAS

10 EQUIPMENT TEMPERATURE LIMITS AND RESISTANCE TO HEAT4.4 SINGLE FAULT CONDITION4.4.2.7.2 MAINS TRANSFORMER SHORT CIRCUIT4.4.2.7.3 MAINS TRANSFORMER OVERLOAD4.4.2.8 OUTPUT ABNORMAL5.1.3 MAINS SUPPLY5.3 DURABILITY OF MARKINGS6.2 DETERMINATION OF ACCESSIBLE PARTS6.3 LIMIT VALUES FOR ACCESSIBLE PARTS6.5.2.3.J TIGHTENING TORQUE6.5.2.4 IMPEDANCE OF PROTECTIVE BONDING PLUG-CONNECTED EQUIPMENT6.5.2.5 IMPEDANCE OF PROTECTIVE BONDING OF PERMANENTLY CONNECTED EQUIPMENT6.7 INSULATION RESISTANCEANNEX K Insulation requirements not covered by 6.76.8 DIELECTRIC VOLTAGE WITHSTAND 6.8.2 Humidity preconditioning8.2.1 ENCLOSURE RIGIDITY TEST- STATIC8.2.2 IMPACT4.4.1 COMPONENT ABNORMAL4.4.2.3 PROTECTIVE CONDUCTOR ABNORMAL 9.4 LIMITED ENERGY CIRCUIT DETERMINATION
2018-08-08

MEAS

10 EQUIPMENT TEMPERATURE LIMITS AND RESISTANCE TO HEAT4.4.1.101.1 OVERLOAD TEST4.4.1.101.2 SWITCHING DEVICES - ENDURANCE TEST6.5.2.102 PROTECTIVE EARTHING REQUIREMENTS FOR ENCLOSED EQUIPMENT
2019-07-03

MEAS

10 EQUIPMENT TEMPERATURE LIMITS AND RESISTANCE TO HEAT10.3 OTHER TEMPERATURE MEASUREMENTS10.4 CONDUCT OF TEMPERATURE TESTS10.5.2 RESISTANCE TO HEAT OF NONMETALLIC ENCLOSURE TEST4.4.1.101.1 OVERLOAD TEST4.4.1.101.2 SWITCHING DEVICES - ENDURANCE TEST4.4.4.16 STAND-ALONE INVERTERS - LOAD TRANSFER 6.5.2.102 PROTECTIVE EARTHING REQUIREMENTS FOR ENCLOSED EQUIPMENT6.5.2.5 IMPEDANCE OF PROTECTIVE BONDING OF PERMANENTLY CONNECTED EQUIPMENT8.2.2 IMPACT9.4 LIMITED ENERGY
2019-07-03