REGAL BELOIT AMERICA INC
REGAL BELOIT AMERICA INC
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2020-12-09 |
Further information
Stage | Country | Name |
---|---|---|
3 | Denmark |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
HOUS | IEC 60335-1:2020 | 10 POWER INPUT AND CURRENT11 HEATING13.2 LEAKAGE CURRENT AT OPERATING TEMPERATURE13.3 ELECTRIC STRENGTH AT OPERATING TEMPERATURE15.3 MOISTURE RESISTANCE - HUMIDITY16.2 LEAKAGE CURRENT AFTER HUMIDITY TREATMENT16.3 ELECTRIC STRENGTH AFTER HUMIDITY TREATMENT19.7 ABNORMAL OPERATION - LOCKED ROTOR19.8 ABNORMAL OPERATION – DISCONNECTED PHASE19.9 ABNORMAL OPERATION - RUNNING OVERLOAD19.11.2 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - FAULT CONDITIONS19.11.3 ABNORMAL OPERATION - PROTECTIVE ELECTRONIC CIRCUIT19.14 ABNORMAL OPERATION - CONTACTOR OR RELAY SHORT CIRCUIT23.5 INTERNAL WIRING - ELECTRIC STRENGTH TEST24.5 COMPONENT - VOLTAGE ACROSS CAPACITOR27.5 EARTHING IMPEDANCE TEST19.11.4.8 RELIABILITY OF PROGRAMMABLE COMPONENTS22.18 INSPECTION FOR CORROSION (FOLLOWING ABNORMAL OPERATION) TEST19.11.4.1 ELECTROSTATIC DISCHARGE19.11.4.3 ELECTRICAL FAST TRANSIENT 19.11.4.4 SURGE IMMUNITY TEST19.11.4.6 VOLTAGE DIPS, VOLTAGE INTERRUPTIONS AND VOLTAGE VARIATIONS IN THE POWER SUPPLY NETWORK | 2022-05-03 | |
HOUS | IEC 60335-1:2010 | 10 POWER INPUT AND CURRENT11 HEATING13.2 LEAKAGE CURRENT AT OPERATING TEMPERATURE13.3 ELECTRIC STRENGTH AT OPERATING TEMPERATURE15.3 MOISTURE RESISTANCE - HUMIDITY16.2 LEAKAGE CURRENT AFTER HUMIDITY TREATMENT16.3 ELECTRIC STRENGTH AFTER HUMIDITY TREATMENT19.7 ABNORMAL OPERATION - LOCKED ROTOR19.8 ABNORMAL OPERATION – DISCONNECTED PHASE19.9 ABNORMAL OPERATION - RUNNING OVERLOAD19.11.2 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - FAULT CONDITIONS19.11.3 ABNORMAL OPERATION - PROTECTIVE ELECTRONIC CIRCUIT19.14 ABNORMAL OPERATION - CONTACTOR OR RELAY SHORT CIRCUIT23.5 INTERNAL WIRING - ELECTRIC STRENGTH TEST24.5 COMPONENT - VOLTAGE ACROSS CAPACITOR27.5 EARTHING IMPEDANCE TEST19.11.4.8 RELIABILITY OF PROGRAMMABLE COMPONENTS22.18 INSPECTION FOR CORROSION (FOLLOWING ABNORMAL OPERATION) TEST19.11.4.1 ELECTROSTATIC DISCHARGE19.11.4.3 ELECTRICAL FAST TRANSIENT 19.11.4.4 SURGE IMMUNITY TEST19.11.4.6 VOLTAGE DIPS, VOLTAGE INTERRUPTIONS AND VOLTAGE VARIATIONS IN THE POWER SUPPLY NETWORK | 2020-12-09 | |
HOUS | IEC 60335-1:2010/AMD1:2013 | 10 POWER INPUT AND CURRENT11 HEATING13.2 LEAKAGE CURRENT AT OPERATING TEMPERATURE13.3 ELECTRIC STRENGTH AT OPERATING TEMPERATURE15.3 MOISTURE RESISTANCE - HUMIDITY16.2 LEAKAGE CURRENT AFTER HUMIDITY TREATMENT16.3 ELECTRIC STRENGTH AFTER HUMIDITY TREATMENT19.7 ABNORMAL OPERATION - LOCKED ROTOR19.8 ABNORMAL OPERATION – DISCONNECTED PHASE19.9 ABNORMAL OPERATION - RUNNING OVERLOAD19.11.2 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - FAULT CONDITIONS19.11.3 ABNORMAL OPERATION - PROTECTIVE ELECTRONIC CIRCUIT19.14 ABNORMAL OPERATION - CONTACTOR OR RELAY SHORT CIRCUIT23.5 INTERNAL WIRING - ELECTRIC STRENGTH TEST24.5 COMPONENT - VOLTAGE ACROSS CAPACITOR27.5 EARTHING IMPEDANCE TEST19.11.4.8 RELIABILITY OF PROGRAMMABLE COMPONENTS22.18 INSPECTION FOR CORROSION (FOLLOWING ABNORMAL OPERATION) TEST19.11.4.1 ELECTROSTATIC DISCHARGE19.11.4.3 ELECTRICAL FAST TRANSIENT 19.11.4.4 SURGE IMMUNITY TEST19.11.4.6 VOLTAGE DIPS, VOLTAGE INTERRUPTIONS AND VOLTAGE VARIATIONS IN THE POWER SUPPLY NETWORK | 2020-12-09 | |
HOUS | IEC 60335-1:2010/AMD2:2016 | 10 POWER INPUT AND CURRENT11 HEATING13.2 LEAKAGE CURRENT AT OPERATING TEMPERATURE13.3 ELECTRIC STRENGTH AT OPERATING TEMPERATURE15.3 MOISTURE RESISTANCE - HUMIDITY16.2 LEAKAGE CURRENT AFTER HUMIDITY TREATMENT16.3 ELECTRIC STRENGTH AFTER HUMIDITY TREATMENT19.7 ABNORMAL OPERATION - LOCKED ROTOR19.8 ABNORMAL OPERATION – DISCONNECTED PHASE19.9 ABNORMAL OPERATION - RUNNING OVERLOAD19.11.2 ABNORMAL OPERATION - ELECTRONIC CIRCUITS - FAULT CONDITIONS19.11.3 ABNORMAL OPERATION - PROTECTIVE ELECTRONIC CIRCUIT19.14 ABNORMAL OPERATION - CONTACTOR OR RELAY SHORT CIRCUIT23.5 INTERNAL WIRING - ELECTRIC STRENGTH TEST24.5 COMPONENT - VOLTAGE ACROSS CAPACITOR27.5 EARTHING IMPEDANCE TEST19.11.4.8 RELIABILITY OF PROGRAMMABLE COMPONENTS22.18 INSPECTION FOR CORROSION (FOLLOWING ABNORMAL OPERATION) TEST19.11.4.1 ELECTROSTATIC DISCHARGE19.11.4.3 ELECTRICAL FAST TRANSIENT 19.11.4.4 SURGE IMMUNITY TEST19.11.4.6 VOLTAGE DIPS, VOLTAGE INTERRUPTIONS AND VOLTAGE VARIATIONS IN THE POWER SUPPLY NETWORK | 2020-12-09 |