Miele & Cie. KG Gütersloh EMC Laboratory Miele
Miele & Cie. KG Gütersloh EMC Laboratory Miele
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2018-11-22 |
Further information
Stage | Country | Name |
---|---|---|
3 | Germany |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
EMC | CISPR 11:2015 | Except magnetic field strength measurement and on additional lines | 2024-07-31 | |
EMC | CISPR 11:2015/AMD1:2016 | Except magnetic field strength measurement and on additional lines | 2024-07-31 | |
EMC | CISPR 11:2015/AMD2:2019 | Except magnetic field strength measurement and on additional lines | 2024-07-31 | |
EMC | CISPR 14-1:2020 | Except magnetic field strength measurement and on additional lines | 2023-07-06 | |
EMC | CISPR 14-1:2016 | All clauses, except magnetic field strength measurement and additional lines | 2018-11-30 | |
EMC | CISPR 14-1:2005 | All clauses, except magnetic field strength measurement and additional lines | 2018-11-30 | |
EMC | CISPR 14-1:2005/AMD1:2008 | All clauses, except magnetic field strength measurement and additional lines | 2018-11-30 | |
EMC | CISPR 14-1:2005/AMD2:2011 | All clauses, except magnetic field strength measurement and additional lines | 2018-11-30 | |
EMC | CISPR 14-2:2020 | All clauses | ||
EMC | CISPR 22:2008 | All clauses, except magnetic field strength measurement and additional lines | 2018-11-30 | |
EMC | CISPR 32:2015 | All clauses, except magnetic field strength measurement and additional lines | 2018-11-30 | |
EMC | CISPR 32:2015/AMD1:2019 | Except magnetic field strength measurement and on additional lines | ||
EMC | IEC 61000-3-2:2018 | All clauses | ||
EMC | IEC 61000-3-2:2018/AMD1:2020 | All clauses | ||
EMC | IEC 61000-3-2:2014 | Clause 19.11.4.1-19.11.4.8 | 2018-11-30 | |
EMC | IEC 61000-3-3:2013 | All clauses | ||
EMC | IEC 61000-3-3:2013/AMD1:2017 | All clauses | ||
EMC | IEC 61000-3-3:2013/AMD2:2021 | All clauses | ||
EMC | IEC 61000-3-11:2017 | Up to 16 A | ||
EMC | IEC 61000-6-1:2016 | Except magnetic immunity | 2024-07-31 | |
EMC | IEC 61000-6-2:2016 | Except magnetic immunity | 2024-07-31 | |
EMC | IEC 61000-6-3:2020 | Except measurement on additional lines | 2024-07-31 | |
EMC | IEC 61000-6-4:2018 | Except measurement on additional lines Except magnetic immunity Except measurement on additional lines | 2024-07-31 | |
EMC | IEC 61326-1:2020 | Except measurement on additional lines Except magnetic immunity | 2024-07-31 | |
EMC | IEC 62233:2005 | Clause 19.11.4.1-19.11.4.8 | 2018-11-30 | |
HOUS | IEC 60335-1:2020 | Clause 19.11.4.1-19.11.4.8 | ||
HOUS | IEC 60335-1:2010 | Accepted clauses: 19.11.4.1-19.11.4.8 | 2018-11-30 | |
HOUS | IEC 60335-1:2010/AMD1:2013 | Clause 19.11.4.1-19.11.4.8 | ||
HOUS | IEC 60335-1:2010/AMD2:2016 | Clause 19.11.4.1-19.11.4.8 |