K & N Schalterentwicklungsges.m.b.H.
K & N Schalterentwicklungsges.m.b.H.
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2014-12-01 |
Further information
Stage | Country | Name |
---|---|---|
2 | Austria |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
POW | IEC 60947-1:2020 | Annex Q: Categories A and B only | 2020-09-29 | |
POW | IEC 60947-1:2007 | Annex Q: Categories A and B only | 2014-12-01 | |
POW | IEC 60947-1:2007/AMD1:2010 | Annex Q: Categories A and B only | 2014-12-01 | |
POW | IEC 60947-1:2007/AMD2:2014 | Annex Q: Categories A and B only | 2020-09-29 | |
POW | IEC 60947-3:2020 | All clauses except test sequence IV. Test sequence I, II and III limited to 200A max. | 2020-09-29 | |
POW | IEC 60947-3:2008 | All clauses except test sequence IV. Test sequence I, II and III limited to 200A max. | 2014-12-01 | |
POW | IEC 60947-3:2008/AMD1:2012 | All clauses except test sequence IV. Test sequence I, II and III limited to 200A max. | 2014-12-01 | |
POW | IEC 60947-3:2008/AMD2:2015 | All clauses except test sequence IV. Test sequence I, II and III limited to 200A max. | 2020-09-29 | |
POW | IEC 60947-4-1:2023 | All clauses except test sequence 3. Test sequence 2 and 4 limited to 200A max. | 2024-10-22 | |
POW | IEC 60947-4-1:2018 | All clauses except test sequence 3. Test sequence 2 and 4 limited to 200A max | 2020-09-29 | |
POW | IEC 60947-4-1:2009 | All clauses except test sequence 3. Test sequence 2 and 4 limited to 200A max | 2014-12-01 | |
POW | IEC 60947-4-1:2009/AMD1:2012 | All clauses except test sequence 3. Test sequence 2 and 4 limited to 200A max. | 2014-12-01 | |
POW | IEC 60947-5-1:2016 | All clauses except test sequence IV. | 2020-09-29 | |
POW | IEC 60947-5-1:2003 | All clauses except test sequence IV. | 2014-12-01 | |
POW | IEC 60947-5-1:2003/AMD1:2009 | All clauses except test sequence IV. | 2014-12-01 |