Hunan Megmeet Electrical Technology Co., Ltd

Address(es)
  • No.76 Hongshupo Road, Changsha Economic and Technological
    Development Zone, Changsha
    Hu'nan 410100
    China

Website Not available
Status

MEMBER

Acceptance date 2024-06-14

Further information

Stage

Country

Name

1

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

ITAV

5.2.2.1-5.2.2.6 – CLASSIFICATION OF ELECTRICAL ENERGY SOURCES5.4.1.3 – TEST FOR HYGROSCOPIC MATERIALS5.4.1.8 – DETERMINATION OF WORKING VOLTAGE5.4.1.10.3 – BALL PRESSURE TEST5.4.5 – ANTENNA TERMINAL INSULATION5.4.9.1 – ELECTRIC STRENGTH TEST – TYPE TESTING OF SOLID INSULATION5.5.2.2 – CAPACITOR DISCHARGE AFTER DISCONNECTION OF A CONNECTOR5.7.4 – TOUCH VOLTAGE AND TOUCH CURRENT MEASUREMENT – UNEARTHED ACCESSIBLE PARTS6.2.2.2, 6.2.2.3 – POWER MEASUREMENTSB.2.5 – INPUT TEST: SINGLE PHASEB.2.6, 5.4.1.4, 6.3, 9.3, B.1.5 – NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENTB.3 – SIMULATED ABNORMAL OPERATING CONDITIONSB.4 – SIMULATED SINGLE FAULT CONDITIONSF.3.10 – TEST FOR THE PERMANENCE OF MARKINGSG.5.3.3 – TRANSFORMER OVERLOADT.2, 5.4.2.6, 5.4.3.2, G.15.2.6 – STEADY FORCE TEST, 10 N
2024-08-08

MED

4.11 – POWER INPUT5.7 – HUMIDITY CONDITIONING7.1.3 - DURABILITY OF MARKINGS8.4.2 - LIMITATION OF VOLTAGE, CURRENT OR POWER8.4.3 - VOLTAGE OR CHARGE LIMITATION8.5.4 - WORKING VOLTAGE MEASUREMENTS8.6.4 A - IMPEDANCE AND CURRENT CARRYING CAPABILITY8.7 - LEAKAGE CURRENT TESTS8.7.4.5 - EARTH LEAKAGE CURRENT8.7.4.6 - TOUCH LEAKAGE CURRENT8.7.3 E) - NON-FREQUENCY-WEIGHTED LEAKAGE CURRENT8.8.3 - DIELECTRIC VOLTAGE WITHSTAND8.8.4.1 - BALL PRESSURE11 – TEMPERATURE13 - ABNORMAL OPERATION TESTING13.2 - IMPAIRMENT OF COOLING15.5.1.2 - TRANSFORMER SHORT CIRCUIT15.5.1.3 - TRANSFORMER OVERLOAD
2024-08-08

MED

4.11 – POWER INPUT5.7 – HUMIDITY CONDITIONING7.1.3 - DURABILITY OF MARKINGS8.4.2 - LIMITATION OF VOLTAGE, CURRENT OR POWER8.4.3 - VOLTAGE OR CHARGE LIMITATION8.5.4 - WORKING VOLTAGE MEASUREMENTS8.6.4 A - IMPEDANCE AND CURRENT CARRYING CAPABILITY8.7 - LEAKAGE CURRENT TESTS8.7.4.5 - EARTH LEAKAGE CURRENT8.7.4.6 - TOUCH LEAKAGE CURRENT8.7.3 E) - NON-FREQUENCY-WEIGHTED LEAKAGE CURRENT8.8.3 - DIELECTRIC VOLTAGE WITHSTAND8.8.4.1 - BALL PRESSURE11 – TEMPERATURE13 - ABNORMAL OPERATION TESTING13.2 - IMPAIRMENT OF COOLING15.5.1.2 - TRANSFORMER SHORT CIRCUIT15.5.1.3 - TRANSFORMER OVERLOAD
2024-08-08

MED

4.11 – POWER INPUT5.7 – HUMIDITY CONDITIONING7.1.3 - DURABILITY OF MARKINGS8.4.2 - LIMITATION OF VOLTAGE, CURRENT OR POWER8.4.3 - VOLTAGE OR CHARGE LIMITATION8.5.4 - WORKING VOLTAGE MEASUREMENTS8.6.4 A - IMPEDANCE AND CURRENT CARRYING CAPABILITY8.7 - LEAKAGE CURRENT TESTS8.7.4.5 - EARTH LEAKAGE CURRENT8.7.4.6 - TOUCH LEAKAGE CURRENT8.7.3 E) - NON-FREQUENCY-WEIGHTED LEAKAGE CURRENT8.8.3 - DIELECTRIC VOLTAGE WITHSTAND8.8.4.1 - BALL PRESSURE11 – TEMPERATURE13 - ABNORMAL OPERATION TESTING13.2 - IMPAIRMENT OF COOLING15.5.1.2 - TRANSFORMER SHORT CIRCUIT15.5.1.3 - TRANSFORMER OVERLOAD
2024-08-08