HPL Electric & Power Ltd. (DEKRA-540)
HPL Electric & Power Ltd. (DEKRA-540)
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2021-05-06 |
Further information
Stage | Country | Name |
---|---|---|
2 | Netherlands |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
POW | IEC 60947-1:2020 | All clauses,Electrical Endurance: 415 Vac, 3 Phase, 50 Hz, 1 to 125 A, Power factor: 0.35 to Unity PF),Expect Short Circuit and EMC | 2023-01-23 | |
POW | IEC 60947-1:2007 | All clauses,Electrical Endurance: 415 Vac, 3 Phase, 50 Hz, 1 to 125 A, Power factor: 0.35 to Unity PF),Expect Short Circuit and EMC | 2023-01-23 | |
POW | IEC 60947-1:2007/AMD1:2010 | All clauses,Electrical Endurance: 415 Vac, 3 Phase, 50 Hz, 1 to 125 A, Power factor: 0.35 to Unity PF),Expect Short Circuit and EMC | 2023-01-23 | |
POW | IEC 60947-1:2007/AMD2:2014 | All clauses,Electrical Endurance: 415 Vac, 3 Phase, 50 Hz, 1 to 125 A, Power factor: 0.35 to Unity PF),Expect Short Circuit and EMC | 2023-01-23 | |
POW | IEC 60947-2:2016 | Circuit Breakers onlyAll clauses,Electrical Endurance: 415 Vac, 3 Phase, 50 Hz, 1 to 125 A, Power factor: 0.35 to Unity PF),Expect Test Sequence II and III and EMC | 2021-05-06 | |
POW | IEC 60947-2:2016/AMD1:2019 | Circuit Breakers onlyAll clauses,Electrical Endurance: 415 Vac, 3 Phase, 50 Hz, 1 to 125 A, Power factor: 0.35 to Unity PF),Expect Test Sequence II and III and EMC | 2021-05-06 | |
PROT | IEC 60898-1:2015 | All clauses,Except Test Sequence C1 (9.12.11.2.1 and 9.12.12)Test Sequence C2 (9.12.11.2.2 and 9.12.12)Test Sequence D1 (9.12.11.3 and 9.12.12)Test Sequence E1 (9.12.11.4.2 and 9.12.12)Test Sequence E2 (9.12.11.4.3 and 9.12.12)Test Sequence E3 (9.12.11.4.4 and 9.12.12) | 2021-05-06 | |
PROT | IEC 60898-1:2015/AMD1:2019 | All clauses,Except Test Sequence C1 (9.12.11.2.1 and 9.12.12)Test Sequence C2 (9.12.11.2.2 and 9.12.12)Test Sequence D1 (9.12.11.3 and 9.12.12)Test Sequence E1 (9.12.11.4.2 and 9.12.12)Test Sequence E2 (9.12.11.4.3 and 9.12.12)Test Sequence E3 (9.12.11.4.4 and 9.12.12) | 2021-05-06 | |
PROT | IEC 61008-1:2010 | All clauses,ExceptTest Sequence D1 (9.17 and 9.19, 9.11.2.3a) b)), Test Sequence D2 (9.11.2.3c)), Test Sequence E (9.11.2.4a) and 9.11.2.4c))Test Sequence F (9.11.2.4b) and 9.11.2.2)Test Sequence HTest Sequence ITest Sequence J | 2021-05-06 | |
PROT | IEC 61008-1:2010/AMD1:2012 | All clauses,ExceptTest Sequence D1 (9.17 and 9.19, 9.11.2.3a) b)), Test Sequence D2 (9.11.2.3c)), Test Sequence E (9.11.2.4a) and 9.11.2.4c))Test Sequence F (9.11.2.4b) and 9.11.2.2)Test Sequence HTest Sequence ITest Sequence J | 2021-05-06 | |
PROT | IEC 61008-2-1:1990 | All clauses, Except SC and EMC | 2023-01-23 | |
PROT | IEC 61008-2-2:1990 | All clauses, Except SC and EMC | 2023-01-23 | |
PROT | IEC 61009-1:2010 | All clauses, except short-circuit capacity and EMC | 2021-12-16 | |
PROT | IEC 61009-1:2010/AMD1:2012 | All clauses, except short-circuit capacity and EMC | 2021-12-16 | |
PROT | IEC 61009-1:2010/AMD2:2013 | All clauses,ExceptTest Sequence D1 (9.17 and 9.19, 9.11.2.3a) b)), Test Sequence D2 (9.11.2.3c)), Test Sequence E (9.11.2.4a) and 9.11.2.4c))Test Sequence F (9.11.2.4b) and 9.11.2.2)Test Sequence HTest Sequence ITest Sequence J | 2021-12-16 | |
PROT | IEC 61009-2-1:1991 | All clauses, except short-circuit capacity and EMC | 2021-12-16 | |
PROT | IEC 61009-2-2:1991 | All clauses, except short-circuit capacity and EMC | 2021-12-16 | |
PROT | IEC 62423:2009 | All clauses, except short-circuit capacity and EMC | 2021-12-16 |