Google LLC
Google LLC
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2019-12-04 |
Further information
Stage | Country | Name |
---|---|---|
2 | United States of America |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
CONT | IEC 60730-1:2013 | 10.1.5 Terminal Secureness 10.1.8 Terminals for Fixed and Non-Detachable Cords 10.1.9 Pull Test on Conductors 12.2 Protection Against Humid Conditions 13.1 Insulation Resistance 13.2 Electric Strength 14 Heating 16.2 Environmental Stress of Temperature 17 Endurance 18.2 Impact Resistance 18.9 Actuating Member and Actuating Means 19.1.11 Threaded Parts 22 Resistance to Corrosion 21.3, G.5 Ball Pressure G.3 Glow Wire25.2 Overvoltage and Under voltage Test H.26.5 Voltage Dips and Voltage Interruptions in power supply network H.26.8 Surge Immunity H.26.9 Electrical Fast Transient Burst H.26.11 Electrostatic Discharge H.27.1.1.1 Abnormal Operation H.27.1.1.3 Electronic Circuit Faults | 2021-10-25 | |
CONT | IEC 60730-1:2013/AMD1:2015 | 10.1.5 Terminal Secureness 10.1.8 Terminals for Fixed and Non-Detachable Cords 10.1.9 Pull Test on Conductors 12.2 Protection Against Humid Conditions 13.1 Insulation Resistance 13.2 Electric Strength 14 Heating 16.2 Environmental Stress of Temperature 17 Endurance 18.2 Impact Resistance 18.9 Actuating Member and Actuating Means 19.1.11 Threaded Parts 22 Resistance to Corrosion 21.3, G.5 Ball Pressure G.3 Glow Wire25.2 Overvoltage and Under voltage Test H.26.5 Voltage Dips and Voltage Interruptions in power supply network H.26.8 Surge Immunity H.26.9 Electrical Fast Transient Burst H.26.11 Electrostatic Discharge H.27.1.1.1 Abnormal Operation H.27.1.1.3 Electronic Circuit Faults | 2021-10-25 | |
CONT | IEC 60730-1:2013/AMD2:2020 | 10.1.5 Terminal Secureness 10.1.8 Terminals for Fixed and Non-Detachable Cords 10.1.9 Pull Test on Conductors 12.2 Protection Against Humid Conditions 13.1 Insulation Resistance 13.2 Electric Strength 14 Heating 16.2 Environmental Stress of Temperature 17 Endurance 18.2 Impact Resistance 18.9 Actuating Member and Actuating Means 19.1.11 Threaded Parts 22 Resistance to Corrosion 21.3, G.5 Ball Pressure G.3 Glow Wire25.2 Overvoltage and Under voltage Test H.26.5 Voltage Dips and Voltage Interruptions in power supply network H.26.8 Surge Immunity H.26.9 Electrical Fast Transient Burst H.26.11 Electrostatic Discharge H.27.1.1.1 Abnormal Operation H.27.1.1.3 Electronic Circuit Faults | 2021-10-25 | |
CONT | IEC 60730-2-7:2015 | 11.4 Actions | 2021-10-15 | |
ITAV | IEC 62368-1:2018 | Accepted Clauses: Annex B.2.5 (Input Measurements), 6.3, Annex B.2.6(Normal Operating Conditions Temperature Test), 6.2, 6.3, 9.3, Annex B.2 (Maximum Operating Temperature for Materials, Components and Systems), Annex B.3(Simulated Abnormal Operating Conditions), Annex E.2 (Audio Amplifier Normal Operating Conditions) and Annex E.3 ( Audio Amplifier abnormal operating conditions), Annex Q (Limited Power Source), Annex F.3.10(Test for the Permanence of Markings), 5.4.9(Electric Strength Test), 4.4.3.3, Annex T.7 (Drop Test), 4.4.3.2, Annex T.4, T.5 (Steady Force Test), 8.7(Loading Tests – Wall and Ceiling Mounted Equipment), 4.4.3.4, Annex T.6(Impact), 4.4.3.8, Annex T.8(Stress Relief), 4.1.2, 4.7, Annex DVE (Direct Plug In Blade Securement Test), 4.1.2, 4.7, DVE (Direct Plug In Security of Input Contacts), 5.4.8 (Humidity), 6.2.2 (Power Source Classification), 6.2.3.2(Resistive PIS Determination), 6.3.1, Glow-Wire Flammability, 6.4.3, Annex B.4 [Reduction of likelihood of Ignition under Single Fault Condition (SFC)], 8.4 (Sharp Edge), 8.6.2.2 (Stability), Annex M.4.2 (Secondary Lithium Battery Charging Safeguards), Annex M.4.4, Annex T.7(Drop Test of EUT containing Secondary Lithium Battery), Annex M.3.2(Protection Circuits for Batteries), Annex P.4.2, Metallized Coatings and Adhesives Securing Parts, G.5.4.6, G.5.4.6.3(Secondary DC Locked Rotor Test), Annex V, V.1.2, V.1.3 (Accessible Parts of Equipment) | 2022-06-21 | |
ITAV | IEC 62368-1:2014 | Accepted Clauses: Annex B.2.5 (Input Measurements), 6.3, Annex B.2.6(Normal Operating Conditions Temperature Test), 6.2, 6.3, 9.2.5, Annex B.2 (Maximum Operating Temperature for Materials, Components and Systems), Annex B.3(Simulated Abnormal Operating Conditions), Annex E.1 (Audio Amplifier Normal Operating Conditions) and Annex E.2 ( Audio Amplifier abnormal operating conditions), Annex Q (Limited Power Source), Annex F.3.10(Test for the Permanence of Markings), 5.4.9(Electric Strength Test), 4.4.4.3, Annex T.7 (Drop Test), 4.4.4.2, Annex T.4, T.5 (Steady Force Test), 8.7(Loading Tests – Wall and Ceiling Mounted Equipment), 4.4.4.4, Annex T.6(Impact), 4.4.3.8, Annex T.8(Stress Relief), 4.1.2, 4.7, Annex DVE (Direct Plug In Blade Securement Test), 4.1.2, 4.7, DVE (Direct Plug In Security of Input Contacts), 5.4.8 (Humidity), 6.2.2 (Power Source Classification), 6.2.3.2(Resistive PIS Determination), 6.4.3, Annex B.4 [Reduction of likelihood of Ignition under Single Fault Condition (SFC)], 8.4 (Sharp Edge), 8.6.2.2 (Stability), Annex M.4.2 (Secondary Lithium Battery Charging Safeguards), Annex M.4.4, Annex T.7(Drop Test of EUT containing Secondary Lithium Battery), Annex M.3.2(Protection Circuits for Batteries), G.5.4.6, G.5.4.6.3 (Secondary DC Locked Rotor Test), Annex P.4.2, Metallized Coatings and Adhesives Securing Parts,Annex V, V.1.2, V.1.3 (Accessible Parts of Equipment) | 2019-12-04 | |
MED | IEC 60601-2-47:2012 | Linearity and dynamic range: IEC 60601-2-47, Sub-Clause 201.12.4.4.101Input impedance: IEC 60601-2-47, Sub-Clause 201.12.4.4.102Common mode rejection: IEC 60601-2-47, Sub-Clause 201.12.4.4.103GAIN accuracy: IEC 60601-2-47, Sub-Clause 201.12.4.4.104GAIN stability: IEC 60601-2-47, Sub-Clause 201.12.4.4.105System noise: IEC 60601-2-47, Sub-Clause 201.12.4.4.106Frequency response: IEC 60601-2-47, Sub-Clause 201.12.4.4.108 | 2021-08-18 | |
MISC | IEC 60825-1:2014 | 5 - DETERMINATION OF THE ACCESSIBLE EMISSION LEVEL5.1 - TESTS5.2 - MEASUREMENT OF LASER RADIATION5.4 - MEASUREMENT GEOMETRY5.4.1 - GENERAL5.4.2 - DEFAULT (SIMPLIFIED) EVALUATION5.4.3 - EVALUATION CONDITION FOR EXTENDED SOURCES | 2020-01-28 | |
OFF | IEC 60950-1:2005 | 1.6.2 (Input), 1.7.11(Durability of Marking), 2.5 (Limited Power Source), 2.9.2 (Humidity), 3.1.2 (Sharp Edges), 4.1 (Stability), 4.2.6, 4.2.1(Drop Test), 4.2.10 (Loading Tests – Wall and Ceiling Mounted Equipment), 4.2.1-4.2.4 (Steady Force Test), 4.3.6, Annex P.1 (Direct Plug In Blade Securement Test), 4.3.6, Annex P.1 (Direct Plug In Security of Input Contacts), 4.5.1, 1.4.12, 1.4.13 (Heating Test), Clauses 2.1.1.9, 4.5.1 (Heating Test under normal operating conditions for ITE with audio amplifiers), 5.3 (Abnormal Operating and Fault Conditions), 5.3.6 [(Abnormal Operations Test for Audio Amplifiers in Information Technology Equipment (ITE)), 5.2.2 (Electric Strength Test), 4.2.5, 4.2.1(Impact), 4.2.7, 4.2.1 (Stress Relief), 4.3.8 (Battery Tests), 4.7.3.1, Glow-wire Flammability, Annex B.7 (Secondary DC Locked Rotor Test) | 2019-12-04 | |
OFF | IEC 60950-1:2005/AMD1:2009 | 1.6.2 (Input), 1.7.11(Durability of Marking), 2.5 (Limited Power Source), 2.9.2 (Humidity), 3.1.2 (Sharp Edges), 4.1 (Stability), 4.2.6, 4.2.1(Drop Test), 4.2.10 (Loading Tests – Wall and Ceiling Mounted Equipment), 4.2.1-4.2.4 (Steady Force Test), 4.3.6, Annex P.1 (Direct Plug In Blade Securement Test), 4.3.6, Annex P.1 (Direct Plug In Security of Input Contacts), 4.5.1, 1.4.12, 1.4.13 (Heating Test), Clauses 2.1.1.9, 4.5.1 (Heating Test under normal operating conditions for ITE with audio amplifiers), 5.3 (Abnormal Operating and Fault Conditions), 5.3.6 [(Abnormal Operations Test for Audio Amplifiers in Information Technology Equipment (ITE)), 5.2.2 (Electric Strength Test), 4.2.5, 4.2.1(Impact), 4.2.7, 4.2.1 (Stress Relief), 4.3.8 (Battery Tests), 4.7.3.1, Glow-wire Flammability, Annex B.7 (Secondary DC Locked Rotor Test) | 2019-12-04 | |
OFF | IEC 60950-1:2005/AMD2:2013 | 1.6.2 (Input), 1.7.11(Durability of Marking), 2.5 (Limited Power Source), 2.9.2 (Humidity), 3.1.2 (Sharp Edges), 4.1 (Stability), 4.2.6, 4.2.1(Drop Test), 4.2.10 (Loading Tests – Wall and Ceiling Mounted Equipment), 4.2.1-4.2.4 (Steady Force Test), 4.3.6, Annex P.1 (Direct Plug In Blade Securement Test), 4.3.6, Annex P.1 (Direct Plug In Security of Input Contacts), 4.5.1, 1.4.12, 1.4.13 (Heating Test), Clauses 2.1.1.9, 4.5.1 (Heating Test under normal operating conditions for ITE with audio amplifiers), 5.3 (Abnormal Operating and Fault Conditions), 5.3.6 [(Abnormal Operations Test for Audio Amplifiers in Information Technology Equipment (ITE)), 5.2.2 (Electric Strength Test), 4.2.5, 4.2.1(Impact), 4.2.7, 4.2.1 (Stress Relief), 4.3.8 (Battery Tests), 4.7.3.1, Glow-wire Flammability, Annex B.7 (Secondary DC Locked Rotor Test) | 2019-12-04 |