Fujitsu Limited Numazu Facility
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
ITAV | IEC 62368-1:2023 | All clauses except 1.2.13.16, 1.7.11, 2.1.1.1 (TNV circuit only), 2.1.1.9, 2.3.1, 2.3.4, 2.3.5, 2.9.2, 2.10.3.9, 2.10.4, 2.10.5.4, 2.10.9, 2.10.10, 2.10.11, 2.10.8.4, 2.10.7, 3.2.5.1, 4.2.7, 4.2.8, 4.3.6, 4.3.12, 4.3.13.2, 4.3.13.3, 4.3.13.4, 4.3.13.5, 4.5 (3 phase voltage only), 4.5 (Winding resistance method), 4.5.5, 4.6.2, 4.6.4.2, 4.7.3, 4.7.3.6, 6.2.1, 6.2.2, 7.4.2, 7.4.3, Annex U, Annex Q, Annex AA, Annex CC, Annex EEAll clauses except 1.2.13.16, 1.7.11, 2.1.1.1 (TNV circuit only), 2.1.1.9, 2.3.1, 2.3.4, 2.3.5, 2.9.2, 2.10.3.9, 2.10.4, 2.10.5.4, 2.10.9, 2.10.10, 2.10.11, 2.10.8.4, 2.10.7, 3.2.5.1, 4.2.7, 4.2.8, 4.3.6, 4.3.12, 4.3.13.2, 4.3.13.3, 4.3.13.4, 4.3.13.5, 4.5 (3 phase voltage only), 4.5 (Winding resistance method), 4.5.5, 4.6.2, 4.6.4.2, 4.7.3, 4.7.3.6, 6.2.1, 6.2.2, 7.4.2, 7.4.3, Annex U, Annex Q, Annex AA, Annex CC, Annex EEAll clauses except 4.7, 4.8, 5.4.4.6.5, 5.4.5, 5.4.8, 5.4.10, 5.4.11, 8.5.4.2, 8.5.4.3, 8.5.5.2, 8.6.4, 8.10, 8.12, 9.6, 10, Annex B.3.7, Annex B.4.3, Annex C, Annex D, Annex E, Annex G.5.2, Annex G.5.3.4, Annex G.7.3, Annex G.8.2, Annex G.9, Annex G.10, Annex G.13.6, Annex G.15, Annex G.16, Annex H, Annex J, Annex M, Annex P.3.3, Annex P.4, Annex R, Annex S, Annex T.10, Annex T.11, Annex U, Annex V.1.4, Annex V.1.5, and Annex V.1.6All clauses except 4.7, 4.8, 5.4.4.6.5, 5.4.5, 5.4.8, 5.4.10, 5.4.11, 8.5.4.2, 8.5.4.3, 8.5.5.2, 8.6.4, 8.10, 8.12, 9.6, 10, Annex B.3.7, Annex B.4.3, Annex C, Annex D, Annex E, Annex G.5.2, Annex G.5.3.4, Annex G.7.3, Annex G.8.2, Annex G.9, Annex G.10, Annex G.13.6, Annex G.15, Annex G.16, Annex H, Annex J, Annex M, Annex P.3.3, Annex P.4, Annex R, Annex S, Annex T.10, Annex T.11, Annex U, Annex V.1.4, Annex V.1.5, and Annex V.1.6 | 2024-07-19 | |
ITAV | IEC 62368-1:2018 | All clauses except 4.7, 4.8, 5.4.4.6.5, 5.4.5, 5.4.8, 5.4.10, 5.4.11, 8.5.4.2, 8.5.5.2, 8.6.4, 8.10, 8.12, 10, Annex B.3.7, Annex B.4.3, Annex C, Annex D, Annex E, Annex G.5.2, Annex G.7.3, Annex G.8.3, Annex G.9, Annex G.10, Annex G.15, Annex G.16, Annex H, Annex J, Annex M, Annex P.3.3, Annex P.4, Annex P.5, Annex R, Annex S, Annex T.8, Annex T.10, Annex T.11, Annex U, Annex V.1.4, Annex V.1.5, and Annex V.1.6 | 2020-07-24 | |
ITAV | IEC 62368-1:2014 | All clauses except 4.7, 4.8, 5.4.4.6.5, 5.4.5, 5.4.8, 5.4.10, 5.4.11, 8.5.4.2, 8.5.5.2, 8.6.4, 8.10, 8.12, 10, Annex B.3.7, Annex B.4.3, Annex C, Annex D, Annex E, Annex G.5.2, Annex G.7.3, Annex G.8.3, Annex G.9, Annex G.10, Annex G.15, Annex G.16, Annex H, Annex J, Annex M, Annex P.3.3, Annex P.4, Annex P.5, Annex R, Annex S, Annex T.8, Annex T.10, Annex T.11, Annex U, Annex V.1.4, Annex V.1.5, and Annex V.1.6 | 2020-07-24 | |
OFF | IEC 60950-1:2005 | Accepted all clauses, except followings:1.2.13.16, 1.7.11, 2.1.1.1 (TNV circuit only),2.1.1.9, 2.3.1, 2.3.4, 2.3.5, 2.9.2, 2.10.3.9, 2.10.4,2.10.5.4, 2.10.9, 2.10.10, 2.10.11, 2.10.8.4,2.10.7, 3.2.5.1, 4.2.7, 4.2.8, 4.3.6, 4.3.12, 4.3.13.2,4.3.13.3, 4.3.13.4, 4.3.13.5, 4.5 (3 phase voltageonly), 4.5 (Winding resistance method), 4.5.5, 4.6.2,4.6.4.2, 4.7.3, 4.7.3.6, 6.2.1, 6.2.2, 7.4.2, 7.4.3,Annex U, Annex Q, Annex AA, Annex CC, AnnexEE | 2016-07-14 | |
OFF | IEC 60950-1:2005/AMD1:2009 | Accepted all clauses, except followings:1.2.13.16, 1.7.11, 2.1.1.1 (TNV circuit only),2.1.1.9, 2.3.1, 2.3.4, 2.3.5, 2.9.2, 2.10.3.9, 2.10.4,2.10.5.4, 2.10.9, 2.10.10, 2.10.11, 2.10.8.4,2.10.7, 3.2.5.1, 4.2.7, 4.2.8, 4.3.6, 4.3.12, 4.3.13.2,4.3.13.3, 4.3.13.4, 4.3.13.5, 4.5 (3 phase voltageonly), 4.5 (Winding resistance method), 4.5.5, 4.6.2,4.6.4.2, 4.7.3, 4.7.3.6, 6.2.1, 6.2.2, 7.4.2, 7.4.3,Annex U, Annex Q, Annex AA, Annex CC, AnnexEE | 2016-07-14 | |
OFF | IEC 60950-1:2005/AMD2:2013 | Accepted all clauses, except followings:1.2.13.16, 1.7.11, 2.1.1.1 (TNV circuit only),2.1.1.9, 2.3.1, 2.3.4, 2.3.5, 2.9.2, 2.10.3.9, 2.10.4,2.10.5.4, 2.10.9, 2.10.10, 2.10.11, 2.10.8.4,2.10.7, 3.2.5.1, 4.2.7, 4.2.8, 4.3.6, 4.3.12, 4.3.13.2,4.3.13.3, 4.3.13.4, 4.3.13.5, 4.5 (3 phase voltageonly), 4.5 (Winding resistance method), 4.5.5, 4.6.2,4.6.4.2, 4.7.3, 4.7.3.6, 6.2.1, 6.2.2, 7.4.2, 7.4.3,Annex U, Annex Q, Annex AA, Annex CC, AnnexEE | 2016-07-14 |