f'Real Foods, LLC

Address(es)
  • 2100 Powell Street, Suite 700
    Emeryville 94608
    CA
    United States of America

Website Not available
Status

MEMBER

Acceptance date 2023-05-08

Further information

Stage

Country

Name

1

Germany

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

HOUS

Accepted clauses listed.7.14 - Marking test8.1.1 - Protection against accidental contact w ith live parts10 - Power input and current11 - Heating13 - Leakage current and electric strength at operating temperature15 - Moisture resistance16 - Leakage current and electric strength19 - Abnormal operation20 - Stability and mechanical hazards21 - Mechanical strength22.5 - Capacitor discharge22.47 - Water pressure Test25 - Supply connection and external flexible cords25.15 - Pull and torque test of supply cord27 - Provision for earthing27.5 DV.5 - Resistance of earthing conductors and their terminations27.5 DV.6 - Impedance test29 - Creepage and Clearances30 - Resistance To Heat And Fire
2023-05-08

HOUS

Accepted clauses listed.7.14 - Marking test8.1.1 - Protection against accidental contact w ith live parts10 - Power input and current11 - Heating13 - Leakage current and electric strength at operating temperature15 - Moisture resistance16 - Leakage current and electric strength19 - Abnormal operation20 - Stability and mechanical hazards21 - Mechanical strength22.5 - Capacitor discharge22.47 - Water pressure Test25 - Supply connection and external flexible cords25.15 - Pull and torque test of supply cord27 - Provision for earthing27.5 DV.5 - Resistance of earthing conductors and their terminations27.5 DV.6 - Impedance test29 - Creepage and Clearances30 - Resistance To Heat And Fire
2023-05-08

HOUS

Accepted clauses listed.7.14 - Marking test8.1.1 - Protection against accidental contact w ith live parts10 - Power input and current11 - Heating13 - Leakage current and electric strength at operating temperature15 - Moisture resistance16 - Leakage current and electric strength19 - Abnormal operation20 - Stability and mechanical hazards21 - Mechanical strength22.5 - Capacitor discharge22.47 - Water pressure Test25 - Supply connection and external flexible cords25.15 - Pull and torque test of supply cord27 - Provision for earthing27.5 DV.5 - Resistance of earthing conductors and their terminations27.5 DV.6 - Impedance test29 - Creepage and Clearances30 - Resistance To Heat And Fire
2023-05-08

HOUS

All Clauses
2023-05-01

HOUS

All Clauses
2023-05-01

HOUS

All Clauses
2023-05-01

HOUS

All Clauses
2023-05-01

HOUS

All Clauses
2023-05-01