Emerson Climate Technologies (Suzhou), Ltd

Address(es)
  • No. 35 Suhong West Road, Suzhou Industrial Park, Suzhou 215021
    Jiangsu Province, China
    China

Website Not available
Status

WITHDRAWN

Acceptance date 2019-06-06

Further information

Stage

Country

Name

2

United States of America

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

CONT

9.3 Adequacy Of Earth Connections10.2.4.3 Push/Pull Test For Tabs12.2 Protection Against Humid Conditions13.2 Electric Strength Test14 Heating Test16.2 Environmental Stress Of Temperature17 Endurance22.1 Resistance To Corrosion2.1.5, 2.1.6, 2.16DV SELV (Class 2) Output Voltage Measurement24.2.1DV.2 / 24.4.1 Switch Mode Power Supply Tests (SMPS)- Overload Test25.2 Overvoltage And Undervoltage TestH.8 Protection Against Electric ShockH.17.1.4.2 Thermal Cycling TestH.26.4 Harmonics And Interharmonics Including Mains Signalling At A.C. Power Port, Low Frequency Immunity TestsH.26.5.1 Voltage Dips And Interruptions – AC Supply OnlyH.26.5.2 Voltage Variation Test – AC Supply OnlyH.26.6 Test of Influence of Voltage UnbalanceH.26.8 Surge Immunity TestH.26.9 Electrical Fast Transient/Burst Immunity TestH.26.10 Ring Wave Immunity TestH.26.11 Electrostatic Discharge TestH.26.13 Test Of Influence Of Supply Frequency GenerationsH.26.15 Evaluation Of ComplianceH.27.1.1 Abnormal OperationH.27.1.1.3, H.27.1.1.4 Electronic Circuit Faults
2019-05-31

CONT

9.3 Adequacy Of Earth Connections10.2.4.3 Push/Pull Test For Tabs12.2 Protection Against Humid Conditions13.2 Electric Strength Test14 Heating Test16.2 Environmental Stress Of Temperature17 Endurance22.1 Resistance To Corrosion2.1.5, 2.1.6, 2.16DV SELV (Class 2) Output Voltage Measurement24.2.1DV.2 / 24.4.1 Switch Mode Power Supply Tests (SMPS)- Overload Test25.2 Overvoltage And Undervoltage TestH.8 Protection Against Electric ShockH.17.1.4.2 Thermal Cycling TestH.26.4 Harmonics And Interharmonics Including Mains Signalling At A.C. Power Port, Low Frequency Immunity TestsH.26.5.1 Voltage Dips And Interruptions – AC Supply OnlyH.26.5.2 Voltage Variation Test – AC Supply OnlyH.26.6 Test of Influence of Voltage UnbalanceH.26.8 Surge Immunity TestH.26.9 Electrical Fast Transient/Burst Immunity TestH.26.10 Ring Wave Immunity TestH.26.11 Electrostatic Discharge TestH.26.13 Test Of Influence Of Supply Frequency GenerationsH.26.15 Evaluation Of ComplianceH.27.1.1 Abnormal OperationH.27.1.1.3, H.27.1.1.4 Electronic Circuit Faults
2019-05-31