EMERSON CLIMATE TECHNOLOGIES S R O

Address(es)
  • K VAPENCE 1633/14

    CZ-69201 MIKULOV
    Czech Republic

Website Not available
Status

MEMBER

Acceptance date 2021-09-22

Further information

Stage

Country

Name

2

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

HOUS

• Cl 13: Electric Strength At Operating Temperature• Cl 16: Leakage Current And Electric Strength• Cl 19: Abnormal Operation• Cl 22.7: Construction
2021-11-08

HOUS

• Cl 13: Electric Strength At Operating Temperature• Cl 16: Leakage Current And Electric Strength• Cl 19: Abnormal Operation• Cl 22.7: Construction
2021-11-08

HOUS

• Cl 13: Electric Strength At Operating Temperature• Cl 16: Leakage Current And Electric Strength• Cl 19: Abnormal Operation• Cl 22.7: Construction
2021-11-08

HOUS

• Cl 19.101/19.104: Abnormal Operation - Locked-Rotor Conditions - Self-Resetting Protectors• Cl 19.104, 16.2: Leakage Current At The End Of Abnormal Test• Cl 19.104, 16.3: Electric Strength At Operating Temperature Test At The End Of Abnormal Test• Cl 19.102: Abnormal Operation- Locked-Rotor Temperature Test With Open And Shorted Capacitors• Cl 19.103: Abnormal Operation – Secondary Single Phasing Locked-Rotor Temperature Test• Cl 19.105: Abnormal Operation – Primary Single Phasing Test• Cl 22.7, 22.101 DV.1: Construction Motor Compressor Enclosure Strength TestAnnex AA; Running overload tests for motor-compressors classified as tested with Annex AA
2021-11-08

HOUS

• Cl 19.101/19.104: Abnormal Operation - Locked-Rotor Conditions - Self-Resetting Protectors• Cl 19.104, 16.2: Leakage Current At The End Of Abnormal Test• Cl 19.104, 16.3: Electric Strength At Operating Temperature Test At The End Of Abnormal Test• Cl 19.102: Abnormal Operation- Locked-Rotor Temperature Test With Open And Shorted Capacitors• Cl 19.103: Abnormal Operation – Secondary Single Phasing Locked-Rotor Temperature Test• Cl 19.105: Abnormal Operation – Primary Single Phasing Test• Cl 22.7, 22.101 DV.1: Construction Motor Compressor Enclosure Strength TestAnnex AA; Running overload tests for motor-compressors classified as tested with Annex AA
2021-11-08

HOUS

• Cl 19.101/19.104: Abnormal Operation - Locked-Rotor Conditions - Self-Resetting Protectors• Cl 19.104, 16.2: Leakage Current At The End Of Abnormal Test• Cl 19.104, 16.3: Electric Strength At Operating Temperature Test At The End Of Abnormal Test• Cl 19.102: Abnormal Operation- Locked-Rotor Temperature Test With Open And Shorted Capacitors• Cl 19.103: Abnormal Operation – Secondary Single Phasing Locked-Rotor Temperature Test• Cl 19.105: Abnormal Operation – Primary Single Phasing Test• Cl 22.7, 22.101 DV.1: Construction Motor Compressor Enclosure Strength TestAnnex AA; Running overload tests for motor-compressors classified as tested with Annex AA
2021-11-08