Delta Electronics (Dongguan) Co., Ltd

Address(es)
  • No.33, Pantao Road, Shijie Town, Dongguan,
    Guangdong 523308
    China

Website Not available
Status

MEMBER

Acceptance date 2011-06-25

Further information

Stage

Country

Name

2

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

ITAV

All clauses
2024-07-19

ITAV

4.4.3.2, T.3 - STEADY FORCE TEST, 30 N FOR SAFEGUARD THAT ACTS AS FIRE ENCLOSURE/BARRIER ONLY4.4.3.2, T.4 - STEADY FORCE TEST, 100 N4.4.3.2, T.5 - STEADY FORCE TEST, 250 N4.4.3.3, T.7 - DROP TEST4.4.3.4, T.6 - IMPACT TEST4.4.3.8, T.8 - STRESS RELIEF TEST4.8.3 – EQUIPMENT CONTAINING COIN/BUTTON CELL BATTERIES: COMPARTMENT OPENING TORQUE TEST4.8.4.2, T.8 – EQUIPMENT CONTAINING COIN/BUTTON CELL BATTERIES: STRESS RELIEF TEST4.8.4.3 – EQUIPMENT CONTAINING COIN/BUTTON CELL BATTERIES: BATTERY REPLACEMENT TEST4.8.4.4 – EQUIPMENT CONTAINING COIN/BUTTON CELL BATTERIES: DROP TEST4.8.4.5 – EQUIPMENT CONTAINING COIN/BUTTON CELL BATTERIES: IMPACT TEST4.8.5 – EQUIPMENT CONTAINING COIN/BUTTON CELL BATTERIES: COMPLIANCE 5.2.2.1-5.2.2.6 – CLASSIFICATION OF ELECTRICAL ENERGY SOURCES5.4.1.3 – TEST FOR HYGROSCOPIC MATERIALS5.4.1.8 ‐ DETERMINATION OF WORKING VOLTAGE5.4.1.10.3 ‐ BALL PRESSURE TEST5.4.2.4 ‐ MINIMUM CLEARANCE BASED UPON ELECTRIC STRENGTH TEST5.4.4.6.2 ‐ SEPARABLE THIN SHEET MATERIAL5.5.2.2 ‐ CAPACITOR DISCHARGE AFTER DISCONNECTION OF A CONNECTOR5.5.8 ‐ INSULATION BETWEEN THE MAINS AND AN EXTERNAL CIRCUIT CONSISTING OF A COAXIAL CABLE 5.4.9.1 – ELECTRIC STRENGTH TEST – TYPE TESTING OF SOLID INSULATION5.6.6.2 - RESISTANCE OF THE PROTECTIVE BONDING SYSTEM5.7.4 – TOUCH VOLTAGE AND TOUCH CURRENT MEASUREMENT – UNEARTHED ACCESSIBLE PARTS5.7.5 – TOUCH CURRENT MEASUREMENT – EARTHED ACCESSIBLE CONDUCTIVE PARTS – SINGLE-PHASE5.7.5 – TOUCH CURRENT MEASUREMENT – EARTHED ACCESSIBLE CONDUCTIVE PARTS – THREE-PHASE EQUIPMENT5.7.6 ‐ PROTECTIVE CONDUCTOR CURRENT6.2.2.2, 6.2.2.3 - POWER MEASUREMENTS6.2.3.1 - ARCING PIS DETERMINATION6.2.3.2 - RESISTIVE PIS DETERMINATION8.5.5.2 – HIGH PRESSURE LAMPS8.6.2 - STATIC STABILITY8.6.3 - RELOCATION STABILITY TEST8.6.4 - GLASS SLIDE TEST8.6.5 - HORIZONTAL FORCE TEST8.7 – WALL, CEILING, OR OTHER STRUCTURE MOUNTING TESTS8.8 - HANDLE STRENGTH8.9 - WHEEL OR CASTER SECUREMENT8.10.3 – CART, STAND OR CARRIER LOADING8.10.4 – CART, STAND OR CARRIER IMPACT8.10.5 – CART, STAND OR CARRIER MECHANICAL STABILITY8.10.6, T.8 – CART, STAND OR CARRIER THERMOPLASTIC TEMPERATURE STABILITY B.2.5 – INPUT TEST: POLYPHASEB.2.5 – INPUT TEST: PRODUCTS CONTAINING AN AUDIO AMPLIFIERB.2.5 – INPUT TEST: TELEVISION RECEIVERS/MONITORSB.2.5 - INPUT TEST: SINGLE PHASEB.2.6, 5.4.1.4, 6.3, 9.3, B.1.5 – NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENTB.3 - SIMULATED ABNORMAL OPERATING CONDITIONSB.4 - SIMULATED SINGLE FAULT CONDITIONSF.3.10 – TEST FOR THE PERMANENCE OF MARKINGSG.5.4.6 - LOCKED-ROTOR OVERLOAD TEST FOR DC MOTORS G.5.4.6.3 - ALTERNATIVE LOCKED-ROTOR OVERLOAD TEST FOR DC MOTORSG.7.3.2 ‐ CORD STRAIN RELIEF TESTG.10.2, G.10.3 - CONDITIONING AND RESISTOR TEST G.16 ‐ IC INCLUDING CAPACITOR DISCHARGE FUNCTION (ICX)M.3.2 – PROTECTION CIRCUITS FOR BATTERIESP.2.3.2 ‐ CONSEQUENCE OF ENTRY TEST Q.1 - LIMITED POWER SOURCE
2024-07-19

ITAV

4.4.4.2, T.4– STEADY FORCE TEST, 100 N 4.4.4.2, T.5 – STEADY FORCE TEST, 250 N 4.4.4.4, T.6 - IMPACT TEST4.4.4.3, T.7 – DROP TEST4.4.4.7, T.8 – STRESS RELIEF TEST4.4.4.6, T.9 – GLASS IMPACT TEST4.7 – EQUIPMENT FOR DIRECT INSERTION INTO MAINS SOCKET-OUTLETS: MOMENT TEST4.7, DVE – EQUIPMENT FOR DIRECT INSERTION INTO MAINS SOCKET-OUTLETS: BLADE SECUREMENT TEST4.7, DVE – EQUIPMENT FOR DIRECT INSERTION INTO MAINS SOCKET-OUTLETS: INPUT BLADE ENDURANCE (RETRACTABLE BLADES)4.7, DVE – EQUIPMENT FOR DIRECT INSERTION INTO MAINS SOCKET-OUTLETS: RESISTANCE TO CRUSHING4.7, DVE - EQUIPMENT FOR DIRECT INSERTION INTO MAINS SOCKET-OUTLETS: ROD PRESSURE TEST4.7, DVE – EQUIPMENT FOR DIRECT INSERTION INTO MAINS SOCKET-OUTLETS: SECURITY OF INPUT CONTACTS4.7, DVE – EQUIPMENT FOR DIRECT INSERTION INTO MAINS SOCKET-OUTLETS: WEIGHT AND MOMENT DETERMINATION5.2.2.1-5.2.2.6 – CLASSIFICATION OF ELECTRICAL ENERGY SOURCES5.4.1.3 – TEST FOR HYGROSCOPIC MATERIALS5.4.1.8 – DETERMINATION OF WORKING VOLTAGE5.4.1.5.2, 5.4.1.5.3 – TEST FOR POLLUTION DEGREE 1 ENVIRONMENT AND FOR AN INSULATING COMPOUND5.4.1.8 ‐ DETERMINATION OF WORKING VOLTAGE5.4.1.10.3 ‐ BALL PRESSURE TEST5.4.2.4 – MINIMUM CLEARANCE BASED UPON ELECTRIC STRENGTH TEST5.4.4.6.2 ‐ SEPARABLE THIN SHEET MATERIAL5.5.2.2 – SAFEGUARDS AGAINST CAPACITOR DISCHARGE AFTER DISCONNECTION OF A CONNECTOR5.5.8 – INSULATION BETWEEN THE MAINS AND AN EXTERNAL CIRCUIT CONSISTING OF A COAXIAL CABLE5.6.6.2 – RESISTANCE OF THE PROTECTIVE BONDING SYSTEM5.7.4 – TOUCH CURRENT MEASUREMENT– EARTHED ACCESSIBLE CONDUCTIVE PARTS5.7.5 ‐ PROTECTIVE CONDUCTOR CURRENT 6.2.2.2, 6.2.2.2, 6.2.2.3 – POWER MEASUREMENTS6.2.3.1 ‐ ARCING PIS DETERMINATION6.2.3.2 ‐ RESISTIVE PIS DETERMINATION6.4.3, ANNEX B.4 ‐ REDUCTION OF THE LIKELIHOOD OF IGNITION UNDER SINGLE FAULT CONDITIONS6.4.3.3 ‐ REDUCTION OF THE LIKELIHOOD OF IGNITION ‐ TEMPERATURES LIMITED BY FUSES6.6 ‐ TEST TO DETERMINE DELIVERED POWER: PS2 DETERMINATION8.5.3, T.8, V ‐ ACCESSIBILITY TO MOVING PARTS8.5.5.2 – HIGH PRESSURE LAMPS8.6.2 – STATIC STABILITY8.6.3 – RELOCATION STABILITY TEST8.6.3.2 – HORIZONTAL FORCE TEST8.6.4 – GLASS SLIDE TEST8.7 ‐ WALL OR CEILING MOUNTING TESTS8.8 ‐ HANDLE STRENGTH8.9 – WHEEL OR CASTER SECUREMENT8.10.3 – CART, STAND OR CARRIER LOADING8.10.4 – CART, STAND OR CARRIER IMPACT8.10.5 – CART, STAND OR CARRIER MECHANICAL STABILITY8.10.6, T.8 – CART, STAND OR CARRIER THERMOPLASTIC TEMPERATURE STABILITY B.2.5 ‐ INPUT TEST: SINGLE PHASE B.2.5 ‐ INPUT TEST: POLYPHASEB.2.5 ‐ INPUT TEST: PRODUCTS CONTAINING AN AUDIO AMPLIFIERB.2.5 ‐ TELEVISION RECEIVERS/MONITORSB.2.6, 5.4.1.4, 6.3, 9.2, B.1.6 – NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENT CONDITIONS TEMPERATURE MEASUREMENTB.3 ‐ SIMULATED ABNORMAL OPERATING CONDITIONSB.4 ‐ SIMULATED SINGLE FAULT CONDITIONS ANNEX F.3.10 ‐ TEST FOR THE PERMANENCE OF MARKINGSG.5.3.3 ‐ TRANSFORMER OVERLOAD ANNEX G.5.3.3.3 ‐ TRANSFORMER OVERLOAD – ALTERNATIVE TEST METHODG.5.4.6.3 ‐ ALTERNATIVE LOCKED‐ROTOR OVERLOAD TEST FOR D.C. MOTORSG.7.3.2 ‐ STRAIN RELIEF TEST G.10.2 ‐ CONDITIONING AND RESISTOR TESTG.13.6 ‐ TESTS ON COATED PRINTED WIRING BOARDS AND COATED COMPONENTS (CONFORMAL COATINGS)G.14 ‐ COATINGS ON COMPONENT TERMINALS G.16 ‐ IC INCLUDING CAPACITOR DISCHARGE FUNCTION (ICX)P.2.3.2 ‐ CONSEQUENCE OF ENTRY TEST Q.1 ‐ LIMITED POWER SOURCET.2, 5.4.2.6, 5.4.3.2, G.15.3.6 – STEADY FORCE TEST, 10 N4.4.4.2, T.3 – STEADY FORCE TEST, 30 N FOR SAFEGUARD THAT ACTS AS FIRE ENCLOSURE/BARRIER ONLY M.3.2– PROTECTION CIRCUITS FOR BATTERIES
2019-01-07

ITAV

5.1 POWER TRANSFER USING ES1 OR ES2 VOLTAGES, GENERAL REQUIREMENTS5.3.2 DC power transfer interconnection to other equipment5.4.1 Requirement for the PSE 5.4.2 Requirement for the PD
2024-07-19

OFF

1.2.2.1 ‐ MAXIMUM OUTPUT VOLTAGE, CURRENT, ANDVOLT‐AMPERE MEASUREMENT TEST1.6.2 ‐ INPUT TEST: SINGLE‐PHASE1.6.2 ‐ INPUT TEST: POLYPHASE1.7.11 ‐ DURABILITY OF MARKING TEST2.1.1.5, 2.1.2, 1.2.8.10 ‐ ENERGY HAZARDMEASUREMENTS2.1.1.7 ‐ CAPACITANCE DISCHARGE TEST2.2.2, 2.2.3, 2.2.4, PART 22 6.1 ‐ SELV RELIABILITY TES2.4.1, 2.4.2 ‐ LIMITED CURRENT CIRCUITMEASUREMENTS2.5 ‐ LIMITED POWER SOURCE MEASUREMENTS2.6.3.4 ‐ LIMITED SHORT‐CIRCUIT TEST2.6.3.4, 2.6.1 ‐ PROTECTIVE BONDING TEST I2.6.3.4, 2.6.1 ‐ PROTECTIVE BONDING TEST II2.6.4.1, 3.3.1 ‐ ENGAGEMENT‐DISENGAGEMENT TEST2.7 ‐ DC CIRCUIT FUSE TEST2.9.1, 2.9.2, 5.2.2 ‐ HUMIDITY TEST2.10.2 ‐ DETERMINATION OF WORKING VOLTAGE ‐WORKING VOLTAGE MEASUREMENT TEST2.10.2 ‐ DETERMINATION OF WORKING VOLTAGE ‐SECONDARY OUTPUT VOLTAGE TEST2.10.5.8, ANNEX AA ‐ MANDREL TEST FOR NON‐SEPARABLE THIN SHEET MATERIAL2.10.5.9, 2.10.5.10, 2.10.5.6 ‐ THIN SHEET MATERIALTESTS2.10.5.13 ‐ Transformer and Wire /Insulation ElectricStrength2.10.8, 2.10.9 ‐ TESTS ON COATED PRINTED WIRINGBOARDS AND COATED COMPONENTS (CONFORMALCOATINGS)2.10.10, 2.10.9 ‐ TEST FOR POLLUTION DEGREE 1ENVIRONMENT AND FOR INSULATING COMPOUND2.10.11, 2.10.9 ‐ TESTS FOR SEMICONDUCTOR DEVICESAND FOR CEMENTED JOINTS3.2.6, 4.2.1, 4.2.7 ‐ STRAIN RELIEF TEST4.1 ‐ STABILITY TESTS4.2.1 ‐ 4.2.4 ‐ STEADY FORCE TESTS4.2.5, 4.2.1, PART 22 10.2 ‐ IMPACT TEST 4.2.6, 4.2.1 ‐ DROP TEST4.2.7, 4.2.1 ‐ STRESS RELIEF TEST4.2.10 ‐ LOADING TESTS – WALL AND CEILING MOUNTED EQUIPMENT4.2.11.1 ‐ RACK MOUNTED EQUIPMENT ‐ MECHANICAL STRENGTH TESTS4.3.1 ‐ SHARP EDGE TEST4.3.2 ‐ KNOB PULL/HANDLE LOADING TEST4.3.5 ‐ CONNECTOR CURRENT INTERRUPTION TEST4.3.6 ‐ DIRECT PLUG IN EQUIPMENT‐MOMENT TEST4.3.8 ‐ BATTERY TESTS4.3.8 ‐ LITHIUM BATTERY REVERSE CURRENT MEASUREMENT TEST4.4.2, 4.4.4 ‐ HAZARDOUS MOVING PARTS TEST4.5.1, 1.4.12, 1.4.13 ‐ HEATING TEST4.5.5, 4.5 ‐ BALL PRESSURE TEST4.6.5 ‐ BARRIER ADHESIVE TEST5.1, ANNEX D ‐ TOUCH CURRENT TEST (SINGLE‐PHASE; TN/TT SYSTEM)5.1, ANNEX D ‐ TOUCH CURRENT TEST (POLYPHASE; TN/TT SYSTEM)5.1, ANNEX D ‐ IT TOUCH CURRENT TEST (SINGLE‐PHASE)5.2.2 ‐ ELECTRIC STRENGTH TEST5.3.1, 5.3.4, 5.3.7 ‐ COMPONENT FAILURE TEST5.3.1, 5.3.9 ‐ ABNORMAL OPERATION TESTS5.3.1, 5.3.9 ‐ ABNORMAL OPERATION – LAMP RUPTURE5.3.3, 5.3.7b, ANNEX C.1 ‐ TRANSFORMER ABNORMAL OPERATION TEST5.3.7 ‐ POWER SUPPLY OUTPUT SHORT‐ CIRCUIT/OVERLOAD TEST5.3.7 ‐ OVERLOAD OF OPERATOR ACCESSIBLE CONNECTOR TEST ANNEX B.7 ‐ LOCKED ROTOR OVERLOAD TEST FOR DC
2019-01-07

OFF

1.2.2.1 ‐ MAXIMUM OUTPUT VOLTAGE, CURRENT, ANDVOLT‐AMPERE MEASUREMENT TEST1.6.2 ‐ INPUT TEST: SINGLE‐PHASE1.6.2 ‐ INPUT TEST: POLYPHASE1.7.11 ‐ DURABILITY OF MARKING TEST2.1.1.5, 2.1.2, 1.2.8.10 ‐ ENERGY HAZARDMEASUREMENTS2.1.1.7 ‐ CAPACITANCE DISCHARGE TEST2.2.2, 2.2.3, 2.2.4, PART 22 6.1 ‐ SELV RELIABILITY TES2.4.1, 2.4.2 ‐ LIMITED CURRENT CIRCUITMEASUREMENTS2.5 ‐ LIMITED POWER SOURCE MEASUREMENTS2.6.3.4 ‐ LIMITED SHORT‐CIRCUIT TEST2.6.3.4, 2.6.1 ‐ PROTECTIVE BONDING TEST I2.6.3.4, 2.6.1 ‐ PROTECTIVE BONDING TEST II2.6.4.1, 3.3.1 ‐ ENGAGEMENT‐DISENGAGEMENT TEST2.7 ‐ DC CIRCUIT FUSE TEST2.9.1, 2.9.2, 5.2.2 ‐ HUMIDITY TEST2.10.2 ‐ DETERMINATION OF WORKING VOLTAGE ‐WORKING VOLTAGE MEASUREMENT TEST2.10.2 ‐ DETERMINATION OF WORKING VOLTAGE ‐SECONDARY OUTPUT VOLTAGE TEST2.10.5.8, ANNEX AA ‐ MANDREL TEST FOR NON‐SEPARABLE THIN SHEET MATERIAL2.10.5.9, 2.10.5.10, 2.10.5.6 ‐ THIN SHEET MATERIALTESTS2.10.5.13 ‐ Transformer and Wire /Insulation ElectricStrength2.10.8, 2.10.9 ‐ TESTS ON COATED PRINTED WIRINGBOARDS AND COATED COMPONENTS (CONFORMALCOATINGS)2.10.10, 2.10.9 ‐ TEST FOR POLLUTION DEGREE 1ENVIRONMENT AND FOR INSULATING COMPOUND2.10.11, 2.10.9 ‐ TESTS FOR SEMICONDUCTOR DEVICESAND FOR CEMENTED JOINTS3.2.6, 4.2.1, 4.2.7 ‐ STRAIN RELIEF TEST4.1 ‐ STABILITY TESTS4.2.1 ‐ 4.2.4 ‐ STEADY FORCE TESTS4.2.5, 4.2.1, PART 22 10.2 ‐ IMPACT TEST 4.2.6, 4.2.1 ‐ DROP TEST4.2.7, 4.2.1 ‐ STRESS RELIEF TEST4.2.10 ‐ LOADING TESTS – WALL AND CEILING MOUNTED EQUIPMENT4.2.11.1 ‐ RACK MOUNTED EQUIPMENT ‐ MECHANICAL STRENGTH TESTS4.3.1 ‐ SHARP EDGE TEST4.3.2 ‐ KNOB PULL/HANDLE LOADING TEST4.3.5 ‐ CONNECTOR CURRENT INTERRUPTION TEST4.3.6 ‐ DIRECT PLUG IN EQUIPMENT‐MOMENT TEST4.3.8 ‐ BATTERY TESTS4.3.8 ‐ LITHIUM BATTERY REVERSE CURRENT MEASUREMENT TEST4.4.2, 4.4.4 ‐ HAZARDOUS MOVING PARTS TEST4.5.1, 1.4.12, 1.4.13 ‐ HEATING TEST4.5.5, 4.5 ‐ BALL PRESSURE TEST4.6.5 ‐ BARRIER ADHESIVE TEST5.1, ANNEX D ‐ TOUCH CURRENT TEST (SINGLE‐PHASE; TN/TT SYSTEM)5.1, ANNEX D ‐ TOUCH CURRENT TEST (POLYPHASE; TN/TT SYSTEM)5.1, ANNEX D ‐ IT TOUCH CURRENT TEST (SINGLE‐PHASE)5.2.2 ‐ ELECTRIC STRENGTH TEST5.3.1, 5.3.4, 5.3.7 ‐ COMPONENT FAILURE TEST5.3.1, 5.3.9 ‐ ABNORMAL OPERATION TESTS5.3.1, 5.3.9 ‐ ABNORMAL OPERATION – LAMP RUPTURE5.3.3, 5.3.7b, ANNEX C.1 ‐ TRANSFORMER ABNORMAL OPERATION TEST5.3.7 ‐ POWER SUPPLY OUTPUT SHORT‐ CIRCUIT/OVERLOAD TEST5.3.7 ‐ OVERLOAD OF OPERATOR ACCESSIBLE CONNECTOR TEST ANNEX B.7 ‐ LOCKED ROTOR OVERLOAD TEST FOR DC
2019-01-07

OFF

1.2.2.1 ‐ MAXIMUM OUTPUT VOLTAGE, CURRENT, ANDVOLT‐AMPERE MEASUREMENT TEST1.6.2 ‐ INPUT TEST: SINGLE‐PHASE1.6.2 ‐ INPUT TEST: POLYPHASE1.7.11 ‐ DURABILITY OF MARKING TEST2.1.1.5, 2.1.2, 1.2.8.10 ‐ ENERGY HAZARDMEASUREMENTS2.1.1.7 ‐ CAPACITANCE DISCHARGE TEST2.2.2, 2.2.3, 2.2.4, PART 22 6.1 ‐ SELV RELIABILITY TES2.4.1, 2.4.2 ‐ LIMITED CURRENT CIRCUITMEASUREMENTS2.5 ‐ LIMITED POWER SOURCE MEASUREMENTS2.6.3.4 ‐ LIMITED SHORT‐CIRCUIT TEST2.6.3.4, 2.6.1 ‐ PROTECTIVE BONDING TEST I2.6.3.4, 2.6.1 ‐ PROTECTIVE BONDING TEST II2.6.4.1, 3.3.1 ‐ ENGAGEMENT‐DISENGAGEMENT TEST2.7 ‐ DC CIRCUIT FUSE TEST2.9.1, 2.9.2, 5.2.2 ‐ HUMIDITY TEST2.10.2 ‐ DETERMINATION OF WORKING VOLTAGE ‐WORKING VOLTAGE MEASUREMENT TEST2.10.2 ‐ DETERMINATION OF WORKING VOLTAGE ‐SECONDARY OUTPUT VOLTAGE TEST2.10.5.8, ANNEX AA ‐ MANDREL TEST FOR NON‐SEPARABLE THIN SHEET MATERIAL2.10.5.9, 2.10.5.10, 2.10.5.6 ‐ THIN SHEET MATERIALTESTS2.10.5.13 ‐ Transformer and Wire /Insulation ElectricStrength2.10.8, 2.10.9 ‐ TESTS ON COATED PRINTED WIRINGBOARDS AND COATED COMPONENTS (CONFORMALCOATINGS)2.10.10, 2.10.9 ‐ TEST FOR POLLUTION DEGREE 1ENVIRONMENT AND FOR INSULATING COMPOUND2.10.11, 2.10.9 ‐ TESTS FOR SEMICONDUCTOR DEVICESAND FOR CEMENTED JOINTS3.2.6, 4.2.1, 4.2.7 ‐ STRAIN RELIEF TEST4.1 ‐ STABILITY TESTS4.2.1 ‐ 4.2.4 ‐ STEADY FORCE TESTS4.2.5, 4.2.1, PART 22 10.2 ‐ IMPACT TEST 4.2.6, 4.2.1 ‐ DROP TEST4.2.7, 4.2.1 ‐ STRESS RELIEF TEST4.2.10 ‐ LOADING TESTS – WALL AND CEILING MOUNTED EQUIPMENT4.2.11.1 ‐ RACK MOUNTED EQUIPMENT ‐ MECHANICAL STRENGTH TESTS4.3.1 ‐ SHARP EDGE TEST4.3.2 ‐ KNOB PULL/HANDLE LOADING TEST4.3.5 ‐ CONNECTOR CURRENT INTERRUPTION TEST4.3.6 ‐ DIRECT PLUG IN EQUIPMENT‐MOMENT TEST4.3.8 ‐ BATTERY TESTS4.3.8 ‐ LITHIUM BATTERY REVERSE CURRENT MEASUREMENT TEST4.4.2, 4.4.4 ‐ HAZARDOUS MOVING PARTS TEST4.5.1, 1.4.12, 1.4.13 ‐ HEATING TEST4.5.5, 4.5 ‐ BALL PRESSURE TEST4.6.5 ‐ BARRIER ADHESIVE TEST5.1, ANNEX D ‐ TOUCH CURRENT TEST (SINGLE‐PHASE; TN/TT SYSTEM)5.1, ANNEX D ‐ TOUCH CURRENT TEST (POLYPHASE; TN/TT SYSTEM)5.1, ANNEX D ‐ IT TOUCH CURRENT TEST (SINGLE‐PHASE)5.2.2 ‐ ELECTRIC STRENGTH TEST5.3.1, 5.3.4, 5.3.7 ‐ COMPONENT FAILURE TEST5.3.1, 5.3.9 ‐ ABNORMAL OPERATION TESTS5.3.1, 5.3.9 ‐ ABNORMAL OPERATION – LAMP RUPTURE5.3.3, 5.3.7b, ANNEX C.1 ‐ TRANSFORMER ABNORMAL OPERATION TEST5.3.7 ‐ POWER SUPPLY OUTPUT SHORT‐ CIRCUIT/OVERLOAD TEST5.3.7 ‐ OVERLOAD OF OPERATOR ACCESSIBLE CONNECTOR TEST ANNEX B.7 ‐ LOCKED ROTOR OVERLOAD TEST FOR DC
2019-01-07

TRON

4.2 INPUT TEST FOR APPARATUS NOT EMPLOYING SIGNAL INPUTS AND NOT CONTAINING AN AUDIO AMPLIFIERFAULT CONDITIONS ‐ GENERAL4.3.2, 4.3.3, 4.3.5 FAULT CONDITIONS ‐ CLEARANCE AND CREEPAGE, INSULATING MATERIALS AND ELECTRONIC COMPONENTS4.3.10 FAULT CONDITIONS ‐ OUTPUT TERMINAL OVERLOAD4.3.11 FAULT CONDITIONS ‐ VENTILATION OPENINGS BLOCKED11 DIELECTRIC STRENGTH AFTER FAULT CONDITIONS11.1 TOUCH CURRENT AFTER FAULT CONDITIONS 5 MARKING DURABILITY AND LEGIBILITY7 HEATING UNDER NORMAL OPERATING CONDITIONS8.8 WINDING INSULATION TEST9.1.1 TOUCH CURRENT9.1.6 WITHDRAWAL OF MAINS PLUGENCLOSURE RESISTANCE TO EXTERNAL FORCES TEST
2019-01-07

TRON

4.2 INPUT TEST FOR APPARATUS NOT EMPLOYING SIGNAL INPUTS AND NOT CONTAINING AN AUDIO AMPLIFIER4.3 FAULT CONDITIONS ‐ GENERAL 4.3.1, 4.3.2, 4.3.4 FAULT CONDITIONS ‐ CLEARANCE AND CREEPAGE, INSULATING MATERIALS AND ELECTRONIC COMPONENTS4.3.9 FAULT CONDITIONS ‐ OUTPUT TERMINAL OVERLOAD4.3.10 FAULT CONDITIONS ‐ VENTILATION OPENINGS BLOCKED11 DIELECTRIC STRENGTH AFTER FAULT CONDITIONS11.1 TOUCH CURRENT AFTER FAULT CONDITIONS 5 MARKING DURABILITY AND LEGIBILITY7 HEATING UNDER NORMAL OPERATING CONDITIONS8.8 WINDING INSULATION TEST9.1.1 TOUCH CURRENT9.1.6 WITHDRAWAL OF MAINS PLUG9.1.7 ENCLOSURE RESISTANCE TO EXTERNAL FORCES TEST10.1 SURGE TEST10.2 HUMIDITY TREATMENT10.3 INSULATION RESISTANCE AND DIELECTRIC STRENGTH AFTER HUMIDITY TREATMENT12.1.2 VIBRATION TEST12.1.3 IMPACT TEST12.1.3 DIELECTRIC STRENGTH AFTER IMPACT TEST IEC 60065,12.1.3 IMPACT TEST IEC 60065,12.1.3 DIELECTRIC STRENGTH AFTER IMPACT TEST12.1.4 DROP TEST12.1.4 DIELECTRIC STRENGTH AFTER DROP TEST12.1.5 STRESS RELIEF TEST12.1.6 HANDLE STRENGTH TEST13.2 DETERMINATION OF OPERATING VOLTAGE15.4.1 MOMENT DETERMINATION FOR DEVICES FORMING A PART OF THE MAINS PLUG ‐ DIRECT PLUG‐IN UNIT15.4.3a DROP TEST ‐ DIRECT PLUG‐IN UNIT15.4.3b BLADE TORQUE TEST ‐ DIRECT PLUG‐IN UNIT15.4.3c BLADE SECURENESS PULL TEST ‐ DIRECT PLUG‐IN UNIT16.5 MAINS FLEXIBLE CORD STRAIN AND TORQUE TEST16.5 MAINS FLEXIBLE CORD STRAIN AND TORQUE TEST FOLLOWING STRESS RELIEF CONDITIONING 17.1 SCREW SECUREMENT TEST
2019-01-07

TRON

4.2 INPUT TEST FOR APPARATUS NOT EMPLOYING SIGNAL INPUTS AND NOT CONTAINING AN AUDIO AMPLIFIER4.3 FAULT CONDITIONS ‐ GENERAL 4.3.1, 4.3.2, 4.3.4 FAULT CONDITIONS ‐ CLEARANCE AND CREEPAGE, INSULATING MATERIALS AND ELECTRONIC COMPONENTS4.3.9 FAULT CONDITIONS ‐ OUTPUT TERMINAL OVERLOAD4.3.10 FAULT CONDITIONS ‐ VENTILATION OPENINGS BLOCKED11 DIELECTRIC STRENGTH AFTER FAULT CONDITIONS11.1 TOUCH CURRENT AFTER FAULT CONDITIONS 5 MARKING DURABILITY AND LEGIBILITY7 HEATING UNDER NORMAL OPERATING CONDITIONS8.8 WINDING INSULATION TEST9.1.1 TOUCH CURRENT9.1.6 WITHDRAWAL OF MAINS PLUG9.1.7 ENCLOSURE RESISTANCE TO EXTERNAL FORCES TEST10.1 SURGE TEST10.2 HUMIDITY TREATMENT10.3 INSULATION RESISTANCE AND DIELECTRIC STRENGTH AFTER HUMIDITY TREATMENT12.1.2 VIBRATION TEST12.1.3 IMPACT TEST12.1.3 DIELECTRIC STRENGTH AFTER IMPACT TEST IEC 60065,12.1.3 IMPACT TEST IEC 60065,12.1.3 DIELECTRIC STRENGTH AFTER IMPACT TEST12.1.4 DROP TEST12.1.4 DIELECTRIC STRENGTH AFTER DROP TEST12.1.5 STRESS RELIEF TEST12.1.6 HANDLE STRENGTH TEST13.2 DETERMINATION OF OPERATING VOLTAGE15.4.1 MOMENT DETERMINATION FOR DEVICES FORMING A PART OF THE MAINS PLUG ‐ DIRECT PLUG‐IN UNIT15.4.3a DROP TEST ‐ DIRECT PLUG‐IN UNIT15.4.3b BLADE TORQUE TEST ‐ DIRECT PLUG‐IN UNIT15.4.3c BLADE SECURENESS PULL TEST ‐ DIRECT PLUG‐IN UNIT16.5 MAINS FLEXIBLE CORD STRAIN AND TORQUE TEST16.5 MAINS FLEXIBLE CORD STRAIN AND TORQUE TEST FOLLOWING STRESS RELIEF CONDITIONING 17.1 SCREW SECUREMENT TEST
2019-01-07

TRON

4.2 INPUT TEST FOR APPARATUS NOT EMPLOYING SIGNAL INPUTS AND NOT CONTAINING AN AUDIO AMPLIFIER4.3 FAULT CONDITIONS ‐ GENERAL 4.3.1, 4.3.2, 4.3.4 FAULT CONDITIONS ‐ CLEARANCE AND CREEPAGE, INSULATING MATERIALS AND ELECTRONIC COMPONENTS4.3.9 FAULT CONDITIONS ‐ OUTPUT TERMINAL OVERLOAD4.3.10 FAULT CONDITIONS ‐ VENTILATION OPENINGS BLOCKED11 DIELECTRIC STRENGTH AFTER FAULT CONDITIONS11.1 TOUCH CURRENT AFTER FAULT CONDITIONS 5 MARKING DURABILITY AND LEGIBILITY7 HEATING UNDER NORMAL OPERATING CONDITIONS8.8 WINDING INSULATION TEST9.1.1 TOUCH CURRENT9.1.6 WITHDRAWAL OF MAINS PLUG9.1.7 ENCLOSURE RESISTANCE TO EXTERNAL FORCES TEST10.1 SURGE TEST10.2 HUMIDITY TREATMENT10.3 INSULATION RESISTANCE AND DIELECTRIC STRENGTH AFTER HUMIDITY TREATMENT12.1.2 VIBRATION TEST12.1.3 IMPACT TEST12.1.3 DIELECTRIC STRENGTH AFTER IMPACT TEST IEC 60065,12.1.3 IMPACT TEST IEC 60065,12.1.3 DIELECTRIC STRENGTH AFTER IMPACT TEST12.1.4 DROP TEST12.1.4 DIELECTRIC STRENGTH AFTER DROP TEST12.1.5 STRESS RELIEF TEST12.1.6 HANDLE STRENGTH TEST13.2 DETERMINATION OF OPERATING VOLTAGE15.4.1 MOMENT DETERMINATION FOR DEVICES FORMING A PART OF THE MAINS PLUG ‐ DIRECT PLUG‐IN UNIT15.4.3a DROP TEST ‐ DIRECT PLUG‐IN UNIT15.4.3b BLADE TORQUE TEST ‐ DIRECT PLUG‐IN UNIT15.4.3c BLADE SECURENESS PULL TEST ‐ DIRECT PLUG‐IN UNIT16.5 MAINS FLEXIBLE CORD STRAIN AND TORQUE TEST16.5 MAINS FLEXIBLE CORD STRAIN AND TORQUE TEST FOLLOWING STRESS RELIEF CONDITIONING 17.1 SCREW SECUREMENT TEST
2019-01-07