A-Dec, Inc.
A-Dec, Inc.
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2010-01-01 |
Further information
Stage | Country | Name |
---|---|---|
3 | United States of America |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
MEAS | IEC 61010-1:2010 | 10.1-10.4 NORMAL TEMPERATURE4.4.2.3 PROTECTIVE CONDUCTOR ABNORMAL5.1.3 INPUT POWER/CURRENT MEASUREMENT5.3 DURABILITY OF MARKINGS6.2 DETERMINATION OF ACCESSIBLE PARTS6.3 PERMISSIBLE LIMITS6.5.2.4 AND 6.5.2.5 GROUNDING CONTINUITY6.7.2.1 CLEARANCES AND CREEPAGE DISTANCES6.8 DIELECTRIC STRENGTH | 2016-10-18 | |
MEAS | IEC 61010-1:2010/AMD1:2016 | 10.1-10.4 NORMAL TEMPERATURE TEST4.4.2.3 PROTECTIVE CONDUCTOR ABNORMAL5.1.3 INPUT POWER/CURRENT MEASUREMENT5.3 DURABILITY OF MARKINGS6.2 DETERMINATION OF ACCESSIBLE PARTS6.3 PERMISSIBLE LIMITS6.5.2.4 AND 6.5.2.5 GROUNDING CONTINUITY TEST6.7.2.1 CLEARANCES AND CREEPAGE DISTANCES6.8 DIELECTRIC STRENGTH | 2020-12-10 | |
MED | IEC 60601-1:2005 | 11 TEMPERATURE11.6.2 OVERFLOW 11.6.3 SPILLAGE11.6.5 LEAKAGE 11.6.6 CLEANING AND DISINFECTION11.8 INTERRUPTION OF POWER SUPPLY13.2 IMPAIRMENT OF COOLING13.2 LOCKING OF MOVING PARTS13.2 INTERRUPTION AND SHORTING OF MOTOR CAPACITOR15.3.2 ENCLOSURE FORCE15.3.3 ENCLOSURE IMPACT15.3.4 DROP IMPACT15.3.5 ROUGH HANDLING15.3.6 MOLD STRESS RELIEF 15.4.7.1 CORD-CONNECTED FOOT OPERATED CONTROL DEVICES15.5.1.2 TRANSFORMERS - SHORT-CIRCUIT TEST15.5.1.3 TRANSFORMERS - OVERLOAD TEST15.5.2 TRANSFORMER DIELECTRIC VOLTAGE WITHSTAND4.11 POWER INPUT5.7 HUMIDITY CONDITIONING 7.1.2 LEGIBILITY OF MARKINGS7.1.3 DURABILITY OF MARKINGS8.11.3.5 CORD ANCHORAGE8.4.2 LIMITATION OF VOLTAGE, CURRENT OR POWER8.4.3 VOLTAGE OR CHARGE LIMITATION8.4.4 VOLTAGE LIMITATION (PART 2)8.6.4 A IMPEDANCE AND CURRENT CARRY CAPABILITY8.7.4.5 EARTH LEAKAGE CURRENT8.7.4.6 TOUCH LEAKAGE CURRENT8.7.4.7 C PATIENT LEAKAGE CURRENT , MAINS ON INPUT/OUTPUT8.7.4.7A PATIENT LEAKAGE CURRENT 8.7.4.7B PATIENT LEAKAGE CURRENT- MAINS ON F-TYPE APPLIED PART8.7.4.7D PATIENT LEAKAGE CURRENT, MAINS ON NON-PE ENCLOSURE8.7.4.7H TOTAL PATIENT LEAKAGE CURRENT8.7.4.8 PATIENT AUXILIARY CURRENT8.8.3 DIELECTRIC VOLTAGE WITHSTAND8.9.4 CREEPAGE DISTANCES AND AIR CLEARANCES9.2.2.2 MEASUREMENT OF GAPS (TRAPPING ZONES)9.4.2 STABILITY AND TRANSPORTABILITY9.4.2.4.2 MOBILE EQUIPMENT FORCE FOR PROPULSION9.4.2.4.3 MOBILE EQUIPMENT OVER A THRESHOLD9.4.3.1 INSTABILITY FROM UNWANTED LATERAL MOVEMENT (INCLUDING SLIDING)9.8.3 TENSILE SAFETY FACTOR9.8.3.1 MECHANICAL STRENGTH - PATIENT SUPPORT SYSTEM9.8.3.2 MECHANICAL STRENGTH - FOOT RESTS/SITTING9.8.3.3 MECHANICAL STRENGTH - DYNAMIC FORCES | 2015-01-12 | |
MED | IEC 60601-1:2005/AMD1:2012 | 11 TEMPERATURE11.6.2 OVERFLOW11.6.3 SPILLAGE11.6.6 CLEANING AND DISINFECTION11.8 INTERRUPTION OF THE POWER SUPPLY13.2 LOCKING OF MOVING PARTS13.2 INTERRUPTION AND SHORTING OF MOTOR CAPACITOR13.2 IMPAIRMENT OF COOLING15.3.2 ENCLOSURE FORCE15.3.3 ENCLOSURE IMPACT15.3.4 DROP IMPACT15.3.5 ROUGH HANDLING15.3.6 MOLD STRESS RELIEF15.4.7.1 CORD-CONNECTED FOOT OPERATED CONTROL DEVICES15.5.1.2 TRANSFORMER SHORT CIRCUIT15.5.1.3 TRANSFORMER - OVERLOAD TEST15.5.2 TRANSFORMER DIELECTRIC VOLTAGE WITHSTAND4.11 POWER INPUT5.7 HUMIDITY CONDITIONING7.1.2 LEGIBILITY OF MARKINGS7.1.3 DURABILITY OF MARKINGS8.11.3.5 CORD ANCHORAGE8.4.2 LIMITATION OF VOLTAGE, CURRENT OR POWER8.4.3 VOLTAGE OR CHARGE LIMITATION8.4.4 VOLTAGE LIMITATION (PART 2)8.6.4 A IMPEDANCE AND CURRENT CARRYING CAPABILITY8.7.4.5 EARTH LEAKAGE CURRENT8.7.4.6 TOUCH LEAKAGE CURRENT8.7.4.7 A PATIENT LEAKAGE CURRENT8.7.4.7 B PATIENT LEAKAGE CURRENT, MAINS ON F-TYPE APPLIED PART8.7.4.7 C PATIENT LEAKAGE CURRENT, MAINS ON INPUT/OUTPUT8.7.4.7 D PATIENT LEAKAGE CURRENT MAINS ON NON-PE ENCLOSURE8.7.4.7 H TOTAL PATIENT LEAKAGE CURRENT8.7.4.8 PATIENT AUXILIARY CURRENT8.8.3 DIELECTRIC VOLTAGE WITHSTAND9.2.2.2 MEASUREMENT OF GAPS (TRAPPING ZONES)9.4.2 STABILITY AND TRANSPORTABILITY9.4.2.4.2 MOBILE EQUIPMENT FORCE FOR PROPULSION9.4.2.4.3 MOBILE EQUIPMENT OVER A THRESHOLD9.4.3.1 INSTABILITY FROM UNWANTED LATERAL MOVEMENT (INCLUDING SLIDING)9.8.2 TENSILE SAFETY FACTOR9.8.3.1 MECHANICAL STRENGTH - PATIENT SUPPORT SYSTEM9.8.3.2 MECHANICAL STRENGTH - FOOT RESTS/SITTING9.8.3.3 MECHANICAL STRENGTH - DYNAMIC FORCES | 2015-01-12 | |
MED | IEC 80601-2-60:2012 | 201.11.1.3 MEASUREMENTS | 2015-01-12 |