Coway Co., Ltd
Coway Co., Ltd
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2019-05-08 |
Further information
Stage | Country | Name |
---|---|---|
2 | Korea, Republic of |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
HOUS | IEC 60335-1:2010 | All clauses except clauses 8.1.4, 14, 19.11.4.2, 19.11.4.7, 21.2, 22.16, 22.18, 22.32, 22.46, 24.1.1~24.1.6, 27.4, 29.3.3 ,31, 32, Annex F, Annex H, Annex J, Annex R, Annex T | 2024-05-23 | |
HOUS | IEC 60335-1:2010/AMD1:2013 | All clauses except clauses 8.1.4, 14, 19.11.4.2, 19.11.4.7, 21.2, 22.16, 22.18, 22.32, 22.46, 24.1.1~24.1.6, 27.4, 29.3.3 ,31, 32, Annex F, Annex H, Annex J, Annex R, Annex T | 2024-05-23 | |
HOUS | IEC 60335-1:2010/AMD2:2016 | All clauses except clauses 8.1.4, 14, 19.11.4.2, 19.11.4.7, 21.2, 22.16, 22.18, 22.32, 22.46, 24.1.1~24.1.6, 27.4, 29.3.3 ,31, 32, Annex F, Annex H, Annex J, Annex R, Annex T | 2024-05-23 | |
HOUS | IEC 60335-2-6:2014 | All clauses except clause 32 and exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-6:2014/AMD1:2018 | All clauses except clause 32 and exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-21:2012 | All clauses other than exception tests of IEC60335-1 | 2020-07-16 | |
HOUS | IEC 60335-2-21:2012/AMD1:2018 | All clauses other than exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-24:2010 | All clauses except test clauses 22.7, 22.127 and exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-24:2010/AMD1:2012 | All clauses except test clauses 22.7, 22.127 and exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-24:2010/AMD2:2017 | All clauses except test clauses 22.7, 22.127 and exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-30:2009 | All clauses other than exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-35:2012 | All clauses other than exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-35:2012/AMD1:2016 | All clauses other than exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-35:2012/AMD2:2020 | All clauses other than exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-40:2018 | All clauses except test clauses 22.108, 22.115, 22.116, 22.121, 22.122, 22.123, 22.124, 22.127, 22.128, 22.129, 23.101, 31 Annex EE, Annex GG, Annex KK, Annex LL, Annex MM, Annex NN and exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-65:2002 | All clauses except test clause 23.101,32, Annex AA and exception tests of IEC60335-1 | 2020-07-16 | |
HOUS | IEC 60335-2-65:2002/AMD1:2008 | All clauses except test clause 23.101,32, Annex AA and exception tests of IEC60335-1 | 2020-07-16 | |
HOUS | IEC 60335-2-65:2002/AMD2:2015 | All clauses except test clause 23.101,32, Annex AA and exception tests of IEC60335-1 | 2024-05-23 | |
HOUS | IEC 60335-2-84:2019 | All clauses except test clause 31 and exception tests of IEC60335-1 | 2024-05-23 |