COOLER MASTER (HUI ZHOU) CO LTD

Address(es)
  • 18 HE CHANG E 4TH RD ZHONG KAI HIGH-TECH INDUSTRIAL DEVELOPMENT ZONE
    HUI ZHOU 516000
    Guangdong
    China

Website Not available
Status

MEMBER

Acceptance date 2024-11-29

Further information

Stage

Country

Name

2

Denmark

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

ITAV

4.4.3.2, T.5 – STEADY FORCE TEST, 250 N4.4.3.4, T.6 - IMPACT TEST5.2.2.1-5.2.2.6 – CLASSIFICATION OF ELECTRICAL ENERGY SOURCES5.4.1.3 – TEST FOR HYGROSCOPIC MATERIALS5.4.9.1 – ELECTRIC STRENGTH TEST – TYPE TESTING OF SOLID INSULATION5.6.6.2 – RESISTANCE OF THE PROTECTIVE BONDING SYSTEM5.7.4 – TOUCH CURRENT MEASUREMENT – EARTHED ACCESSIBLE CONDUCTIVE PARTS – THREE-PHASE EQUIPMENT5.7.5 – PROTECTIVE CONDUCTOR CURRENTB.2.5 – INPUT TEST: POLYPHASEB.2.6, 5.4.1.4, 6.3, 9.2, B.1.6 – NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENTB.3 – SIMULATED ABNORMAL OPERATING CONDITIONSB.4 – SIMULATED SINGLE FAULT CONDITIONSG.5.4.8 – THREE-PHASE MOTORSG.15.3.1 – HYDROSTATIC PRESSURE TESTG.15.3.5 – THERMAL CYCLING TESTG.15.3.6 – FORCE TESTQ.1 – LIMITED POWER SOURCE
2024-11-29

ITAV

4.4.3.2, T.5 – STEADY FORCE TEST, 250 N4.4.3.4, T.6 - IMPACT TEST5.4.1.3 – TEST FOR HYGROSCOPIC MATERIALS5.4.9.1 – ELECTRIC STRENGTH TEST – TYPE TESTING OF SOLID INSULATION5.6.6.2 – RESISTANCE OF THE PROTECTIVE BONDING SYSTEM5.7.4 – TOUCH VOLTAGE AND TOUCH CURRENT MEASUREMENT – UNEARTHED ACCESSIBLE PARTS5.7.5 – TOUCH CURRENT MEASUREMENT – EARTHED ACCESSIBLE CONDUCTIVE PARTS – THREE-PHASE EQUIPMENT5.7.6 – PROTECTIVE CONDUCTOR CURRENTB.2.5 – INPUT TEST: POLYPHASEB.2.6, 5.4.1.4, 6.3, 9.3, B.1.5 – NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENTB.3 – SIMULATED ABNORMAL OPERATING CONDITIONSB.4 – SIMULATED SINGLE FAULT CONDITIONSG.5.4.8 – THREE-PHASE MOTORSG.15.2.1 – HYDROSTATIC PRESSURE TESTG.15.2.5 – THERMAL CYCLING TEST G.15.2.6 – FORCE TESTQ.1 – LIMITED POWER SOURCE
2024-11-29

ITAV

4.4.4.2, T.5 – STEADY FORCE TEST, 250 N4.4.4.4, T.6 - IMPACT TEST5.2.2.1-5.2.2.6 – CLASSIFICATION OF ELECTRICAL ENERGY SOURCES5.4.1.3 – TEST FOR HYGROSCOPIC MATERIALS5.4.9.1 – ELECTRIC STRENGTH TEST – TYPE TESTING OF SOLID INSULATION5.6.6.2 – RESISTANCE OF THE PROTECTIVE BONDING SYSTEM5.7.4 – TOUCH CURRENT MEASUREMENT – EARTHED ACCESSIBLE CONDUCTIVE PARTS – THREE-PHASE EQUIPMENT5.7.5 – PROTECTIVE CONDUCTOR CURRENTB.2.5 – INPUT TEST: POLYPHASEB.2.6, 5.4.1.4, 6.3, 9.2, B.1.6 – NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENTB.3 – SIMULATED ABNORMAL OPERATING CONDITIONSB.4 – SIMULATED SINGLE FAULT CONDITIONSG.5.4.8 – THREE-PHASE MOTORSG.15.3.1 – HYDROSTATIC PRESSURE TESTG.15.3.5 – THERMAL CYCLING TESTG.15.3.6 – FORCE TESTQ.1 – LIMITED POWER SOURCE
2024-11-29