Cadence Design Systems, Inc

Address(es)
  • 2655 Seely Avenue
    San Jose 95134
    United States of America

Website Not available
Status

MEMBER

Acceptance date 2022-10-27

Further information

Stage

Country

Name

1

United States of America

LEGEND: Scope Limitations
  • RA : Audio amplifiers with audio power > 0,5 Watts excluded
  • RC : Apparatus with connection(s) to a cable distribution system excluded
  • RSH : Shredders excluded
  • RT : Apparatus with connection(s) to a telecommunication network excluded
  • RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
  • ROUT : Equipment intended for installation outdoors excluded
  • RWPT : Wireless power transmitter excluded

Category

Name

Tests/Clauses

Acceptance Date

Responsible National Certification Body

ITAV

5.2, 5.7 / CLASSIFICATION OF ELECTRICAL ENERGY SOURCES5.4.1.4, Annex B.2 / MAXIMUM OPERATING TEMPERATURE FOR MATERIALS, COMPONENTS AND SYSTEMS5.4.9 / ELECTRIC STRENGTH TEST:5.5.2.2 / SAFEGUARDS AGAINST CAPACITOR DISCHARGE AFTER DISCONNECTION OF A CAPACITOR5.6.6.2 / RESISTANCE OF THE PROTECTIVE BONDING SYSTEM5.7 / PROSPECTIVE TOUCH VOLTAGE AND TOUCH CURRENT MEASUREMENT5.7.5 / PROTECTIVE CONDUCTOR CURRENT5.7.7 / SUMMATION OF TOUCH CURRENTS FROM EXTERNAL CIRCUITS6.2.2.2, 6.2.2.3 / POWER MEASUREMENTS6.3 / NORMAL OPERATING CONDITIONS TEMPERATURE TEST6.6 / TEST TO DETERMINE DELIVERED POWER: PS2 DETERMINATION8.6.2 / STATIC STABILITY8.6.3 / RELOCATION STABILITY TESTAnnex B.2.5 / INPUT TEST: SINGLE PHASEAnnex B.2.5 / INPUT TEST: POLYPHASEAnnex B.2.6 / NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENTAnnex B.3 / SIMULATED ABNORMAL OPERATING CONDITIONSAnnex B.4 / SIMULATED SINGLE FAULT CONDITIONSAnnex B.4 / SINGLE FAULT CONDITIONS: REDUCE THE LIKELIHOOD OF IGNITION
2024-03-21

ITAV

5.2, 5.7 / CLASSIFICATION OF ELECTRICAL ENERGY SOURCES5.4.1.4, Annex B.2 / MAXIMUM OPERATING TEMPERATURE FOR MATERIALS, COMPONENTS AND SYSTEMS5.4.9 / ELECTRIC STRENGTH TEST:5.5.2.2 / SAFEGUARDS AGAINST CAPACITOR DISCHARGE AFTER DISCONNECTION OF A CAPACITOR5.6.6.2 / RESISTANCE OF THE PROTECTIVE BONDING SYSTEM5.7 / PROSPECTIVE TOUCH VOLTAGE AND TOUCH CURRENT MEASUREMENT5.7.5 / PROTECTIVE CONDUCTOR CURRENT5.7.7 / SUMMATION OF TOUCH CURRENTS FROM EXTERNAL CIRCUITS6.2.2.2, 6.2.2.3 / POWER MEASUREMENTS6.2.3.1, 6.2.3.2 / ARCING PIS/RESISTIVE PIS DETERMINATION6.3 / NORMAL OPERATING CONDITIONS TEMPERATURE TEST6.6 / TEST TO DETERMINE DELIVERED POWER: PS2 DETERMINATION8.6.2 / STATIC STABILITY8.6.3 / RELOCATION STABILITY TESTAnnex B.2.5 / INPUT TEST: SINGLE PHASEAnnex B.2.5 / INPUT TEST: POLYPHASEAnnex B.2.6 / NORMAL OPERATING CONDITIONS TEMPERATURE MEASUREMENTAnnex B.3 / SIMULATED ABNORMAL OPERATING CONDITIONSAnnex B.4 / SIMULATED SINGLE FAULT CONDITIONSAnnex B.4 / SINGLE FAULT CONDITIONS: REDUCE THE LIKELIHOOD OF IGNITION
2022-10-27