BS Service Group S.r.l.
BS Service Group S.r.l.
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2024-03-18 |
Further information
Stage | Country | Name |
---|---|---|
2 | Denmark |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
HOUS | IEC 60335-1:2020 | Accepted Clauses: 7.14, 8.1.1, 8.1.2, 8.1.4 (Limited to SELV voltages only), 8.2, 10, 11, 13, 15.3, 16, 17, 19.7, 19.11.2, 19.13, 19.14, 20.2 (limited to openings with maximum dimension less than 50 mm), 21.1, 22.6, 22.11, 22.12, 23.5, 24.5, 25.15, 25.16, 26.3, 26.5, 27.5, 28, 29 (except for PTI measurements), 30.2 (Limited to Glow-wire and Needle Flame test), Annex D, Annex E | 2024-03-18 | |
HOUS | IEC 60335-1:2010 | 2024-03-18 | ||
HOUS | IEC 60335-1:2010/AMD1:2013 | Accepted Clauses: 7.14, 8.1.1, 8.1.2, 8.1.4 (Limited to SELV voltages only), 8.2, 10, 11, 13, 15.3, 16, 17, 19.7, 19.11.2, 19.13, 19.14, 20.2 (limited to openings with maximum dimension less than 50 mm), 21.1, 22.6, 22.11, 22.12, 23.5, 24.5, 25.15, 25.16, 26.3, 26.5, 27.5, 28, 29 (except for PTI measurements), 30.2 (Limited to Glow-wire and Needle Flame test), Annex D, Annex E | 2024-03-18 | |
HOUS | IEC 60335-1:2010/AMD2:2016 | Accepted Clauses: 7.14, 8.1.1, 8.1.2, 8.1.4 (Limited to SELV voltages only), 8.2, 10, 11, 13, 15.3, 16, 17, 19.7, 19.11.2, 19.13, 19.14, 20.2 (limited to openings with maximum dimension less than 50 mm), 21.1, 22.6, 22.11, 22.12, 23.5, 24.5, 25.15, 25.16, 26.3, 26.5, 27.5, 28, 29 (except for PTI measurements), 30.2 (Limited to Glow-wire and Needle Flame test), Annex D, Annex E | 2024-03-18 | |
HOUS | IEC 60335-2-6:2014 | Accepted Clauses: 10 (Limited to cooktops other than induction cooktops), 11 (Limited to cooktops other than induction cooktops), 13 (Limited to cooktops other than induction cooktops), 16 (Limited to cooktops other than induction cooktops), 19.101, 19.102, 19.103, 22.112, 22.113, 22.114, 22.116, 22.123 (Except for annex R), 22.124 (Except for annex R), 22.133, 22.134 (Except for annex R), 22.138 (Except for annex R), 24.101 | 2024-03-18 | |
HOUS | IEC 60335-2-6:2014/AMD1:2018 | Accepted Clauses: 10 (Limited to cooktops other than induction cooktops), 11 (Limited to cooktops other than induction cooktops), 13 (Limited to cooktops other than induction cooktops), 16 (Limited to cooktops other than induction cooktops), 19.101, 19.102, 19.103, 22.112, 22.113, 22.114, 22.116, 22.123 (Except for annex R), 22.124 (Except for annex R), 22.133, 22.134 (Except for annex R), 22.138 (Except for annex R), 24.101 | 2024-03-18 | |
HOUS | IEC 60335-2-31:2012 | Accepted Clauses: 11, 19.101, 22.103, 30.101 (Limited to Glow-wire and Needle Flame test) | 2024-03-18 | |
HOUS | IEC 60335-2-31:2012/AMD1:2016 | Accepted Clauses: 11, 19.101, 22.103, 30.101 (Limited to Glow-wire and Needle Flame test) | 2024-03-18 | |
HOUS | IEC 60335-2-31:2012/AMD2:2018 | Accepted Clauses: 11, 19.101, 22.103, 30.101 (Limited to Glow-wire and Needle Flame test) | 2024-03-18 |