American Power Conversion Holdings Inc., Taiwan Branch
American Power Conversion Holdings Inc., Taiwan Branch
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2020-07-15 |
Further information
Stage | Country | Name |
---|---|---|
1 | Japan |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
ITAV | IEC 62368-1:2018 | Accepted clauses 5.4.1.4, Annex B.2, 5.4.1.8, 5.4.1.10.3, 5.4.4.6.2, 5.4.8, 5.5.2.2, 5.6.6.2, 5.7, 8.6.2.2, 8.6.2.3, 8.7, 8.8, 9.3, Annex B.2.5, Annex B.2.6, Annex G.5.3.3, Annex G.7.3.2, Annex Q.1, Annex T.2 (5.4.2.6, 5.4.3.2, Annex G.15.3.6), Annex T.3 (4.4.3.2, 4.4.3.5, 5.3.2.3, Annex G.15.2.6, Annex U3), Annex T.4 (4.4.3.2), Annex T.5 (4.4.3.2), Annex T.6 (4.4.3.4, 8.10.4), Annex T.7 (4.4.3.3), Annex T.8 (4.4.3.1, 4.4.3.8, 4.8.4.2, 8.6.1, 8.7.2, 8.10.6, Annex G.7.3.2.4), Annex V.1.2, Annex V.1.3 | 2020-07-15 | |
ITAV | IEC 62368-1:2014 | Accepted clauses 5.4.1.4, Annex B.2, 5.4.1.8, 5.4.1.10.3, 5.4.4.6.2, 5.4.8, 5.5.2.2, 5.6.6.2, 5.7, 8.6.2.2, 8.6.2.3, 8.7, 8.8, 9.2.5, Annex B.2.5, Annex B.2.6, Annex G.5.3.3, Annex G.7.3.2, Annex Q.1, Annex T.2 (5.4.2.6, 5.4.3.2, Annex G.15.3.6), Annex T.3 (4.4.4.2, 4.4.4.5, 5.3.2.3, Annex G.15.3.6, Annex U3), Annex T.4 (4.4.4.2), Annex T.5 (4.4.4.2), Annex T.6 (4.4.4.4, 8.10.4), Annex T.7 (4.4.4.3), Annex T.8 (4.4.4.1, 4.4.4.7, 4.8.4.2, 8.6.1, 8.7.2, 8.10.6, Annex G.7.3.2.4), Annex V.1.2, Annex V.1.3 | 2020-07-15 | |
OFF | IEC 60950-1:2005 | Accepted clauses 1.6.2, 1.7.11, 2.1.1.1, 2.1.1.2, 2.1.1.5, 2.1.1.7, 2.1.1.8, 2.1.2, 2.2.2, 2.2.3, 2.4, 2.5, 2.6.3.4, 2.9.2, 2.10.2, 2.10.3, 2.10.4, 3.2.6, 4.1, 4.2.1, 4.2.2, 4.2.3, 4.2.4, 4.2.5, 4.2.6, 4.2.7, 4.2.10, 4.3.2, 4.3.8, 4.4, 4.5, 4.5.5, 4.6.4.2, 5.1, 5.2, 5.3, Annex B, Annex C and Annex D | 2020-07-15 | |
OFF | IEC 60950-1:2005/AMD1:2009 | Accepted clauses 1.6.2, 1.7.11, 2.1.1.1, 2.1.1.2, 2.1.1.5, 2.1.1.7, 2.1.1.8, 2.1.2, 2.2.2, 2.2.3, 2.4, 2.5, 2.6.3.4, 2.9.2, 2.10.2, 2.10.3, 2.10.4, 3.2.6, 4.1, 4.2.1, 4.2.2, 4.2.3, 4.2.4, 4.2.5, 4.2.6, 4.2.7, 4.2.10, 4.3.2, 4.3.8, 4.4, 4.5, 4.5.5, 4.6.4.2, 5.1, 5.2, 5.3, Annex B, Annex C and Annex D | 2020-07-15 | |
OFF | IEC 60950-1:2005/AMD2:2013 | Accepted clauses 1.6.2, 1.7.11, 2.1.1.1, 2.1.1.2, 2.1.1.5, 2.1.1.7, 2.1.1.8, 2.1.2, 2.2.2, 2.2.3, 2.4, 2.5, 2.6.3.4, 2.9.2, 2.10.2, 2.10.3, 2.10.4, 3.2.6, 4.1, 4.2.1, 4.2.2, 4.2.3, 4.2.4, 4.2.5, 4.2.6, 4.2.7, 4.2.10, 4.3.2, 4.3.8, 4.4, 4.5, 4.5.5, 4.6.4.2, 5.1, 5.2, 5.3, Annex B, Annex C and Annex D | 2020-07-15 | |
OFF | IEC 62040-1:2017 | Accepted clauses 4.4.7.4.1/RD, 5.2.2.1/RD, 5.2.2.2/RD, 5.2.2.4.2.2/RD, 5.2.2.4.2.3/RD, 5.2.2.4.3/RD, 5.2.2.4.4/RD, 5.2.2.4.5/RD, 5.2.2.5/RD, 5.2.2.6/RD, 5.2.2.6.102, 5.2.2.7/RD, 5.2.2.6.102, 5.2.3.4/RD, 5.2.3.6/RD, 5.2.3.7/RD, 5.2.3.8/RD, 5.2.3.9/RD, 5.2.3.10/RD, 5.2.3.101, 5.2.3.11, 5.2.3.102, 5.2.3.104, 5.2.4.4/RD, 5.2.4.5/RD, 5.2.4.6/RD, 5.2.4.7/RD, 5.2.4.9/RD, 5.2.6.3.1/RD, 5.2.6.3.2/RD | 2021-05-15 | |
OFF | IEC 62040-1:2017/AMD1:2021 | Accepted clauses 4.4.7.4.1/RD, 5.2.2.1/RD, 5.2.2.2/RD, 5.2.2.4.2.2/RD, 5.2.2.4.2.3/RD, 5.2.2.4.3/RD, 5.2.2.4.4/RD, 5.2.2.4.5/RD, 5.2.2.5/RD, 5.2.2.6/RD, 5.2.2.6.102, 5.2.2.7/RD, 5.2.2.6.102, 5.2.3.4/RD, 5.2.3.6/RD, 5.2.3.7/RD, 5.2.3.8/RD, 5.2.3.9/RD, 5.2.3.10/RD, 5.2.3.101, 5.2.3.11, 5.2.3.102, 5.2.3.104, 5.2.4.4/RD, 5.2.4.5/RD, 5.2.4.6/RD, 5.2.4.7/RD, 5.2.4.9/RD, 5.2.6.3.1/RD, 5.2.6.3.2/RD | 2022-05-12 | |
OFF | IEC 62040-1:2017/AMD2:2022 | Accepted clauses 4.4.7.4.1/RD, 5.2.2.1/RD, 5.2.2.2/RD, 5.2.2.4.2.2/RD, 5.2.2.4.2.3/RD, 5.2.2.4.3/RD, 5.2.2.4.4/RD, 5.2.2.4.5/RD, 5.2.2.5/RD, 5.2.2.6/RD, 5.2.2.6.102, 5.2.2.7/RD, 5.2.2.6.102, 5.2.3.4/RD, 5.2.3.6/RD, 5.2.3.7/RD, 5.2.3.8/RD, 5.2.3.9/RD, 5.2.3.10/RD, 5.2.3.101, 5.2.3.11, 5.2.3.102, 5.2.3.104, 5.2.4.4/RD, 5.2.4.5/RD, 5.2.4.6/RD, 5.2.4.7/RD, 5.2.4.9/RD, 5.2.6.3.1/RD, 5.2.6.3.2/RD | 2024-05-02 | |
OFF | IEC 62040-1:2008 | Accepted clauses 4.6, 4.7.16, 5.6.2.7, 5.1.2, 5.1.4, 5.2.1, 5.2.3, 5.2.5, 5.3.2, 5.5.3.3, 5.6.2.7, 5.7, 6.2.1, 7.2, 7.3, 7.4.1, 7.4.2, 7.4.4, 7.6.8, 7.7, 8.1, 8.2, 8.3.1, 8.3.2, Annex B, Annex C, Annex D and Annex I | 2020-07-15 | |
OFF | IEC 62040-1:2008/AMD1:2013 | Accepted clauses 4.6, 4.7.16, 5.6.2.7, 5.1.2, 5.1.4, 5.2.1, 5.2.3, 5.2.5, 5.3.2, 5.5.3.3, 5.6.2.7, 5.7, 6.2.1, 7.2, 7.3, 7.4.1, 7.4.2, 7.4.4, 7.6.8, 7.7, 8.1, 8.2, 8.3.1, 8.3.2, Annex B, Annex C, Annex D and Annex I | 2020-07-15 |