Title | Low-voltage surge protective devices - Part 31: Requirements and test methods for SPDs for photovoltaic installations |
Abstract | IEC 61643-31:2018 is applicable to Surge Protective Devices (SPDs), intended for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are designed to be connected to the DC side of photovoltaic installations rated up to 1 500 V DC. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents. Performance characteristics, safety requirements, standard methods for testing and ratings are established. SPDs complying with this standard are exclusively dedicated to be installed on the DC side of photovoltaic generators and the DC side of inverters. SPDs for PV systems with energy storage (e.g. batteries, capacitor banks) are not covered. SPDs with separate input and output terminals that contain specific series impedance between these terminal(s) (so called two-port SPDs according to IEC 61643-11:2011) are not covered. SPDs compliant with this standard are designed to be permanently connected where connection and disconnection of fixed SPDs can only be done using a tool. This standard does not apply to portable SPDs. |
Issue Date | 2018-01-10 |
Category | PROT |
Included in IECEE System | 2018-09-27 |
Purchase | webstore |
Test Report Form | |
Testing Equipment List | No information declared |
DISCLAIMER: National differences
The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.
Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Group/Country | Reference | Last Modified | Differences | TRF Addendum |
---|---|---|---|---|
CENELEC | EN 61643-31 | 2020-04-30 | Download135 kb |
Laboratory Name | City | Country | Responsible National Certification Body |
---|---|---|---|
CTI-VIENNA, (Cooperative Testing Institute for Electrotechnical Products) Ltd. | Vienna | Austria | |
Arnhem | Netherlands | ||
Shanghai 200436 | China | ||
Dongguan City | China | ||
IPH Institut "Prüffeld für elektrische Hochleistungstechnik" GmbH | Berlin | Germany | |
Henan | China | ||
Shanghai | China |
Id | Name | City | Country |
---|---|---|---|
13360 | Arnhem | Netherlands | |
13371 | Kista | Sweden | |
13332 | Vienna | Austria | |
13349 | Budapest | Hungary | |
13344 | Offenbach / Main | Germany |
Id | Name | City | Country |
---|---|---|---|
13363 | Association of Polish Electricians – Quality Testing Office (SEP – BBJ) | Warszawa | Poland |
28154 | Nairobi | Kenya |