IEC 61558-2-15:2011
IEC 61558-2-15:2011
Title | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-15: Particular requirements and tests for isolating transformers for the supply of medical locations |
Abstract | IEC 61558-2-15:2011 deals with safety aspects of isolating transformers for the supply of medical locations. This second edition cancels and replaces the first edition published in 1999. It constitutes a technical revision. The main changes consist of updating this part in accordance with IEC 61558-1:2005. This part has the status of a group safety publication in accordance with IEC Guide 104:2010. The preparation of safety publications and the use of basic safety publications and group safety publications. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months from the date of publication. |
Issue Date | 2011-11-22 |
Category | SAFE |
Included in IECEE System | 2014-07-16 |
Purchase | webstore |
Test Report Form | |
Testing Equipment List |
DISCLAIMER: National differences
The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.
Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Group/Country | Reference | Last Modified | Differences | TRF Addendum |
---|---|---|---|---|
Australia | AS/NZS 61558.2.15:2012 used in conjunction with AS/NZS 61558.1:2008 +A1:2009 +A2:2015 | 2020-10-09 | Download110 kb | |
Australia | AS/NZS 61558.2.15:2012 used in conjunction with AS/NZS 61558.1:2008 +A1:2009 +A2:2015 | 2020-09-10 | Download60 kb | |
Australia | AS/NZS 61558.2.15:2012 used in conjunction with AS/NZS 61558.1:2008 +A1:2009 +A2:2015 | 2020-11-19 | Download110 kb | |
New Zealand | AS/NZS 61558.2.15:2012 used in conjunction with AS/NZS 61558.1:2008 +A1:2009 +A2:2015 | 2020-10-09 | Download110 kb | |
New Zealand | AS/NZS 61558.2.15:2012 used in conjunction with AS/NZS 61558.1:2008 +A1:2009 +A2:2015 | 2020-11-19 | Download110 kb |
Laboratory Name | City | Country | Responsible National Certification Body |
---|---|---|---|
Arnhem | Netherlands | ||
Seoul 08389 | Korea, Republic of | ||
Hartmannsdorf | Germany | ||
TSE Test and Calibration Center Electrotechnical Laboratory Ankara | Bakanliklar/Ankara | Türkiye | |
Budapest | Hungary | ||
Taoyuan City 333 | Chinese Taipei | ||
Frankfurt | Germany | ||
Offenbach / Main | Germany |
Id | Name | City | Country |
---|---|---|---|
13360 | Arnhem | Netherlands | |
13356 | Gyeongsangnam-do | Korea, Republic of | |
13347 | Hartmannsdorf | Germany | |
13373 | Bakanliklar, Ankara | Türkiye | |
13349 | Budapest | Hungary | |
13345 | Nürnberg | Germany | |
13346 | München | Germany | |
13344 | Offenbach / Main | Germany |
Id | Name | City | Country |
---|---|---|---|
13363 | Association of Polish Electricians – Quality Testing Office (SEP – BBJ) | Warszawa | Poland |
28154 | Nairobi | Kenya |