IEC 61439-5:2014

Title
Abstract

IEC 61439-5:2014 defines the specific requirements for public electricity network distribution assemblies (PENDAs). PENDAs have the following criteria:
- used for the distribution of electrical energy in three phase systems for which the rated voltage does not exceed 1 000 V a.c. (see Figure 101 for a typical distribution network);
- open ASSEMBLIES are not covered by this standard;
- suitable for installation in places where only skilled persons have access for their use, however, outdoor types may be installed in situations that are accessible to ordinary persons;
- for indoor or outdoor use.
This second edition cancels and replaces the first edition published in 2010. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the latest edition:
- confirmation that tests carried out on the most onerous PENDA are deemed to verify the performance of similar and less onerous assemblies of the same general construction and rating;
- more precise timing/conditions for impact force withstand tests for PENDAs designed for operation in an arctic climate;
- correction of the direction of the applied force in the static load test.

This publication is to be read in conjunction with IE 61439-1:2011. The contents of the corrigendum of March 2015 have been included in this copy.

Issue Date

2014-08-25

Category

POW

Included in IECEE System

2015-03-06

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

No information declared

Laboratory Name

City

Country

Responsible National Certification Body

Wien

Austria

Lublin

Poland

Vienna

Austria

Arnhem

Netherlands

Fujian

China

Berlin

Germany

Bonn

Germany

NL-7559 SC Hengelo

Netherlands

Shandong

China

Shanghai

China

Wien

Austria

Wuzhong District

China

Tianjin

China

Budapest

Hungary

Offenbach / Main

Germany

Ruian City

China

Jiaxing City

China

Id

Name

City

Country

13363

Warszawa

Poland

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13371

Kista

Sweden

13343

Fontenay-Aux-Roses

France

13332

Vienna

Austria

13349

Budapest

Hungary

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany