IEC 61010-2-091:2019

Title
Abstract

IEC 61010-2-091:2019 is available as IEC 61010-2-091:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61010-2-091:2019 specifies particular safety requirements for cabinet X-ray systems, which fall under any of categories a), b) or c) below.
a) Electrical test and measurement equipment
This is equipment which by electromagnetic means tests, measures, indicates or records one or more electrical or physical quantities, also non-measuring equipment such as signal generators, measurement standards, power supplies for laboratory use, transducers, transmitters, etc.
NOTE 1 This includes bench-top power supplies intended to aid a testing or measuring operation on another piece of equipment. Power supplies intended to power equipment are within the scope of IEC 61558 (see 1.1.2 h)).
This standard also applies to test equipment integrated into manufacturing processes and intended for testing manufactured devices.
NOTE 2 Manufacturing test equipment is likely to be installed adjacent to and interconnected with industrial machinery in this application.
b) Electrical industrial process-control equipment
This is equipment which controls one or more output quantities to specific values, with each value determined by manual setting, by local or remote programming, or by one or more input variables.
c) Electrical laboratory equipment
This is equipment which measures, indicates, monitors, inspects or analyses materials, or is used to prepare materials, and includes in vitro diagnostic (IVD) equipment. This equipment may also be used in areas other than laboratories; examples include selftest IVD equipment to be used in the home and inspection equipment to be used to check people or material during transportation. This second edition cancels and replaces the first edition published in 2012. It constitutes a technical revision. This edition includes the following significant changes from the first edition, as well as numerous other changes:
- The scope of the document has been clarified and limited to equipment up to 500 kV.
- Additional marking requirements for X-ray generating assemblies have been added. (5.1)
- Requirements for high-voltage cables used in the X-ray assembly have been added. (6.5)
- Insulation requirements have been added. (6.7)
- Temperature requirements for beam-limiting devices have been added. (10.3)
- Clarification has been provided on and , and test methods. (12)
- Requirements for have been modified, taking into account functional safety standards. (15)
- Requirements for reasonably foreseeable misuse have been clarified. (16)
- Risk assessment has been made mandatory for specific aspects. (17)

Issue Date

2019-02-15

Category

MEAS

Included in IECEE System

2019-05-01

Purchase webstore
Test Report Form
Testing Equipment List

No information declared

DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

CanadaCanada

2024-01-08

Download53 kb

Laboratory Name

City

Country

Responsible National Certification Body

Arnhem

Netherlands

Osnago (LC)

Italy

Boxborough,

United States of America

Kaufbeuren

Germany

Lake Forest,

United States of America

Kista

Sweden

Shanghai

China

Guangzhou, Guangdong

China

Carlsbad,

United States of America

Pfinztal

Germany

Toronto

Canada

Brussels

Belgium

Helsinki

Finland

Suwanee

United States of America

Shanghai

China

Suzhou

China

Singapore 609937

Singapore

Hannover

Germany

München

Germany

Ballerup

Denmark

Mie 516-0021

Japan

Melville

United States of America

Basingstoke

United Kingdom

Offenbach / Main

Germany

Id

Name

City

Country

13360

Arnhem

Netherlands

13371

Kista

Sweden

13365

Singapore

Singapore

13424

IL 60005

United States of America

13361

Lysaker

Norway

13469

Toronto,

Canada

13334

BRUSSELS 1070

Belgium

13342

Helsinki

Finland

13427

Singapore 609937

Singapore

13346

München

Germany

13340

Ballerup

Denmark

13423

Northbrook

United States of America

13344

Offenbach / Main

Germany

Id

Name

City

Country

13864

COURBEVOIE

France

13422

Milton Keynes

United Kingdom

13336

Toronto, Ontario

Canada

13348

Reichenwalde b. Berlin

Germany