IEC 61010-2-011:2019

Title
Abstract

IEC 61010-2-011:2019 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever that equipment incorporates refrigerating systems as an integral part of, or separate from, the equipment and the equipment is in direct control of the refrigerating system. This document details all the requirements when up to 150 g of flammable refrigerant are used per stage of a refrigerating system. Additional requirements beyond the current scope of this document apply if a refrigerant charge of flammable refrigerant exceeds this amount.
a) Electrical test and measurement equipment
This is equipment which by electromagnetic means tests, measures, indicates or records one or more electrical or physical quantities, also non-measuring equipment such as signal generators, measurement standards, power supplies for laboratory use, transducers, transmitters, etc.
b) Electrical industrial process-control equipment
This is equipment which controls one or more output quantities to specific values, with each value determined by manual setting, by local or remote programming, or by one or more input variables.
c) Electrical laboratory equipment
This is equipment which measures, indicates, monitors, inspects or analyses materials, or is used to prepare materials, and includes in vitro diagnostic (IVD) equipment. This second edition cancels and replaces the first edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with changes introduced by Amendment 1 of IEC 61010-1:2010;
b) introduction of new defined terms or modified terms to align with Part 2-012 and other source documents. Editorial changes to use small capitals only for defined terms. Note the difference of defined term in 4.3.2.101 and abnormal operation in 11.7.104.3 and 11.7.104.5;
c) clarifications for cooling tests in 4.4.2.10;
d) changes pertaining to the accurate employment of the following terms: temperature, operating temperature, application temperature, controlled temperature, room ambient and ambient temperature;
e) use of defined term to replace cooling system;
f) move text of 4.4.2.101 to 4.3.2.101, since the purpose of as defined, is to simulate failure of the ambient conditions of 1.4.1 but not of the of the equipment;
g) use of the term equipment to replace unit, apparatus, appliance, where applicable;
h) in 5.1.2 dd) for high and low sides for each stage are required only under ;
i) use of defined term to replace normal operation;
j) use of defined term to replace user.
It has the status of a group safety publication in accordance with IEC Guide 104.

Issue Date

2019-03-22

Category

MEAS

Included in IECEE System

2019-07-03

Purchase webstore
Test Report Form
Testing Equipment List

No information declared

DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

CanadaCanada

2019-12-02

Download51 kb

CENELECCENELEC

2022-06-24

Download82 kb

CENELECCENELEC

2023-05-05

Download86 kb

CENELECCENELEC

2022-06-24

Download82 kb

United States of AmericaUnited States of America

2024-04-15

Download111 kb

Laboratory Name

City

Country

Responsible National Certification Body

Türkheim

Germany

Littleton 01460

United States of America

94447 Plattling

Germany

Guangzhou

China

Regensdorf

Switzerland

Fehraltorf

Switzerland

Arlington Heights

United States of America

Boxborough,

United States of America

Columbus,

United States of America

Coquitlam, B.C.

Canada

Kaufbeuren

Germany

Duluth,

United States of America

Campoformido (UD)

Italy

Lake Forest,

United States of America

Menlo Park,

United States of America

Fridley, MN

United States of America

Plano,

United States of America

Nänikon

Switzerland

Biassono (MB)

Italy

Carlsbad,

United States of America

Pfinztal

Germany

Toronto

Canada

Puchheim

Germany

Shanghai

China

Suzhou

China

Wuhan

China

Ljubljana

Slovenia

Guangzhou

China

Shanghai

China

Shenzhen

China

Budapest

Hungary

Köln

Germany

Tampa,

United States of America

Jiangsu

China

Frankfurt

Germany

Hannover

Germany

München

Germany

Neu-Isenburg (Zeppelinheim)

Germany

20061 Carugate (MI)

Italy

Mie 516-0021

Japan

Mounds View

United States of America

Suzhou

China

Huangpu District, Guangzhou

China

Offenbach / Main

Germany

Id

Name

City

Country

13336

Toronto, Ontario

Canada

13360

Arnhem

Netherlands

13372

Fehraltorf

Switzerland

13348

Reichenwalde b. Berlin

Germany

13371

Kista

Sweden

13424

IL 60005

United States of America

13343

Fontenay-Aux-Roses

France

13361

Lysaker

Norway

13469

Toronto,

Canada

13334

BRUSSELS 1070

Belgium

13367

Ljubljana

Slovenia

13349

Budapest

Hungary

13345

Nürnberg

Germany

13427

Singapore 609937

Singapore

13346

München

Germany

13340

Ballerup

Denmark

13423

Northbrook

United States of America

13344

Offenbach / Main

Germany

No information declared