IEC 61009-2-2:2024

Title
Abstract

IEC 61009-2-2:2024 applies to residual current operated circuit-breakers, with integral overcurrent protection, for household and similar uses (hereafter referred to as RCBOs), classified according to IEC 61009-1:2024, 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6. RCBOs according to this document are intended for voltages not exceeding 440 V AC with frequencies of 50 Hz, 60 Hz or 50/60 Hz and currents not exceeding 125 A and rated short‑circuit capacities not exceeding 25 000 A for operation at 50 Hz or 60 Hz.
This second edition cancels and replaces the first edition published in 1991. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) harmonization of all clauses between the IEC 61008, IEC 61009 and IEC 60755 series using blocks and modules approach;
b) harmonization of all tables and figures between the IEC 61008, IEC 61009 and IEC 60755 series;
c) terms and definitions are now referred to IEC 62873-2;
d) modification of 4.1 for classification according to supply conditions;
e) modification of Clause 6 for markings of RCBOs with a functional earth (FE);
f) specific tests for operating characteristics of RCBO according to classifications 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6;
g) specific test conditions for dielectric properties (9.7), temperature-rise (9.8), electrical and mechanical endurance (9.10), short-circuit tests (9.11), verification of trip-free (9.15), behaviour in the event of loss of the supply voltage (9.17), surge current tests (9.19), reliability (9.20), ageing (9.21) and temporary overvoltage TOV (9.24);
h) additional tests for RCBOs with a terminal connected to the FE: Connecting capacity of FE terminal (9.200); Limitation of standing current in the FE (9.201).

Issue Date

2024-11-21

Category

PROT

Included in IECEE System

2025-01-10

Purchase webstore
Test Report Form

No information declared

Testing Equipment List

No information declared

DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.