IEC 61009-1:2010

Title
Abstract

IEC 61009-1:2010 applies to residual current operated circuit breakers with integral overcurrent protection functionally independent of, or functionally dependent on, line voltage for household and similar uses (hereafter referred to as RCBOs), for rated voltages not exceeding 440 V a.c. with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A and rated short circuit capacities not exceeding 25 000 A for operation at 50 Hz or 60 Hz. This third edition cancels and replaces the second edition, published in 1996, amendment 1 (2002) and amendment 2 (2006). It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- complete revision of EMC sequences, including the new test T.2.6, already approved in IEC 61543;
- clarification of RCDs current/time characteristics reported in Tables 2 and 3;
- revision of test procedure for IΔn< /sub> between 5 A and 200 A;
- tests for the use of RCBOs in IT systems;
- testing procedure regarding the 6mA d.c. current superimposed to the fault current;
- improvement highlighting RCDs with multiple sensitivity;
- some alignments with IEC 60898-1.

Issue Date

2010-02-11

Category

PROT

Included in IECEE System

2010-03-23

Purchase webstore
Test Report Form
Testing Equipment List

No information declared

DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

AustriaAustria

2020-07-09

Download170 kb

AustriaAustria

2021-10-07

Download169 kb

CENELECCENELEC

2016-05-31

Download778 kb

CENELECCENELEC

2021-10-07

Download598 kb

CENELECCENELEC

2016-05-31

Download551 kb

CENELECCENELEC

2015-12-18

Download26 kb

CENELECCENELEC

2020-05-08

Download602 kb

Korea, Republic ofKorea, Republic of

2016-02-19

Download150 kb

Laboratory Name

City

Country

Responsible National Certification Body

Wien

Austria

Lublin

Poland

Vienna

Austria

Mostoles (Madrid)

Spain

Arnhem

Netherlands

Wenzhou, Zhejiang

China

182 00 Praha 8 – Troja

Czech Republic

Fujian

China

Dongguan City,

China

Xiangtan City

China

Milano

Italy

Berlin

Germany

Kista

Sweden

Shanghai

China

Chungcheongbuk-do

Korea, Republic of

Fontenay-Aux-Roses

France

Liège

Belgium

Shandong

China

Shanghai

China

Wuzhong District

China

Tianjin

China

Budapest

Hungary

Guangzhou

China

Singapore 609937

Singapore

Whitefield

India

Ruian City

China

Wenzhou

China

Jiaxing City

China

Hangzhou

China

Id

Name

City

Country

13370

Madrid

Spain

13363

Warszawa

Poland

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13339

Praha 8 - Troja 171 02

Czech Republic

27108

Guangdong

China

13351

Milano

Italy

13371

Kista

Sweden

13358

Gunpo-si,Gyeonggi-do, 15809

Korea, Republic of

13343

Fontenay-Aux-Roses

France

13332

Vienna

Austria

13334

BRUSSELS 1070

Belgium

13349

Budapest

Hungary

13427

Singapore 609937

Singapore

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany