IEC 60947-8:2003

Title
Abstract

Specifies rules for control units, which perform the switching functions in response to the thermal detectors incorporated in rotating electrical machines according to IEC 60034-11, and the industrial application. It specifies rules for that type of system comprising a positive temperature coefficient (PTC) thermistor detector having particular characteristics, and its associated control unit. The PT100 detectors are covered by IEC 60751, where the resistor values are given according to the temperatures of the detector. The present rules lay down the characteristics of association of this particular positive temperature coefficient thermistor detector and its associated control unit (designated "Mark A detector" and "Mark A control unit"), when they are used in thermal protection systems. NOTE It is not possible to specify all the requirements for the operating characteristics of a control unit, as they are dependent on some aspects of the thermal detectors. Some aspects of the requirements of the thermal protector system can only be specified when account is taken of the characteristics of the rotating machine to be protected and the method of installation of the detector within the machine. For these reasons, for each characteristic it is necessary to specify who is responsible for stating the required values and who is responsible for compliance with the requirement and for carrying out any confirmatory test.

Issue Date

2003-05-27

Category

POW

Included in IECEE System

2007-10-01

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

No information declared

Id

Name

City

Country

13349

Budapest

Hungary

13340

Ballerup

Denmark

13344

Offenbach / Main

Germany

Id

Name

City

Country

13363

Warszawa

Poland

13339

Troja, 182 00 Praha 8

Czech Republic

13371

Kista

Sweden

13361

Lysaker

Norway

13332

Vienna

Austria

13346

München

Germany