IEC 60947-5-2:2007
IEC 60947-5-2:2007
Title | Low-voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches |
Abstract | This part of IEC 60947 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. These proximity switches are self-contained, have semiconductor switching elements(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz a.c. or 300 V d.c. This Standard is not intended to cover proximity switches with analogue outputs. The main changes with respect to the previous edition are as follows:-modification of Table 3;-modifications of voltage dips and voltage interruptions immunity tests, in Table 8;-modification of status of Annex A, now informative. |
Issue Date | 2007-10-09 |
Category | POW |
Included in IECEE System | 2007-11-30 |
Purchase | webstore |
Test Report Form | |
Testing Equipment List | No information declared |
DISCLAIMER: National differences
The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.
Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
No information declared
Laboratory Name | City | Country | Responsible National Certification Body |
---|---|---|---|
Wien | Austria | ||
IPH Institut "Prüffeld für elektrische Hochleistungstechnik" GmbH | Berlin | Germany | |
Shanghai | China | ||
Shanghai Testing & Inspection Institute for Electrical Equipment Co., Ltd. (STIEE) | Shanghai | China | |
Suzhou Electrical Apparatus Science Research Institute Co., Ltd. (EETI) | Wuzhong District | China | |
Budapest | Hungary | ||
TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch | Guangzhou | China | |
Ballerup | Denmark | ||
Northbrook, IL 60062 | United States of America | ||
Offenbach / Main | Germany | ||
Jiaxing City | China |
Id | Name | City | Country |
---|---|---|---|
13338 | Beijing 100070 | China | |
13371 | Kista | Sweden | |
13343 | Fontenay-Aux-Roses | France | |
13332 | Vienna | Austria | |
13349 | Budapest | Hungary | |
13427 | Singapore 609937 | Singapore | |
13340 | Ballerup | Denmark | |
13344 | Offenbach / Main | Germany |
Id | Name | City | Country |
---|---|---|---|
13363 | Association of Polish Electricians – Quality Testing Office (SEP – BBJ) | Warszawa | Poland |
13372 | Fehraltorf | Switzerland | |
13603 | Moscow | Russian Federation | |
13346 | München | Germany |