IEC 60898-2:2016

Title
Abstract

IEC 60898-2:2016 gives additional requirements for single- and two-pole circuit-breakers which, in addition to the above characteristics, are suitable for operation with direct current, and have a rated DC voltage not exceeding 220 V for single-pole and 440 V for two-pole circuit-breakers, a rated current not exceeding 125 A and a rated DC short-circuit capacity not exceeding 10 000 A. This second edition cancels and replaces the first edition published in 2000 and Amendment 1:2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with second edition of IEC 60898-1;
b) introduction of test Icn1.

This publication is to be read in conjunction with IEC 60898-1:2015.

Issue Date

2016-08-17

Category

PROT

Included in IECEE System

2016-11-28

Purchase webstore
Test Report Form
Testing Equipment List

No information declared

DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

Saudi ArabiaSaudi Arabia

2021-05-23

Download409 kb

Laboratory Name

City

Country

Responsible National Certification Body

Wien

Austria

Vienna

Austria

Guangzhou,

China

Arnhem

Netherlands

182 00 Praha 8 – Troja

Czech Republic

Milano

Italy

Berlin

Germany

Shanghai

China

Shanghai

China

Wuzhong District

China

Tianjin

China

Budapest

Hungary

Guangzhou 510656

China

Ruian City

China

Hangzhou

China

Id

Name

City

Country

13338

Beijing 100070

China

13360

Arnhem

Netherlands

13339

Praha 8 - Troja 171 02

Czech Republic

13351

Milano

Italy

13371

Kista

Sweden

13332

Vienna

Austria

13349

Budapest

Hungary

13427

Singapore 609937

Singapore

13344

Offenbach / Main

Germany